Riata silicone defibrillation lead with normal electrical measures at routine ambulatory check:The role of highvoltage shock testing 被引量:1
1
作者 Elia De Maria Ambra Borghi +2 位作者 Lorenzo Bonetti pier luigi fontana Stefano Cappelli 《World Journal of Cardiology》 CAS 2016年第11期657-666,共10页
AIM To describe our experience with shock testing for the evaluation of patients with Riata? leads.METHODS Among 51 patients with normal baseline electrical parameters, 20 died during follow-up. Of the remaining 31 pa... AIM To describe our experience with shock testing for the evaluation of patients with Riata? leads.METHODS Among 51 patients with normal baseline electrical parameters, 20 died during follow-up. Of the remaining 31 patients, 15 underwent the test: In 10 cases a defibrillation testing with ventricular fibrillation(VF) induction and in 5 cases a R-wave-synchronized shock(> 20 J, without inducing VF). The test was performed under sedation with Midazolam. RESULTS Twelve patients(80%) had a normal behavior during shock testing: In 8 cases induced VF was correctly detected and treated; in 4 cases of R-wave-synchronized shock electrical parameters remained stable and normal. Three patients(20%) failed the test. One patient with externalized conductors showed a sudden drop of high-voltage impedance(< 10 Ohm) after a 25 J R-wave-synchronized shock. Two other patients with externalized conductors, undergoing defibrillation testing, showed a short-circuit during shock delivery and the implantable cardioverter defibrillator was unable to interrupt VF.CONCLUSION In Riata? leads the delivery of a low current during routine measurement of high-voltage impedance may not reveal a small short circuit, that can only be evident by attempting to deliver a true shock, either for spontaneous arrhythmias or in the context of a shock testing. 展开更多
关键词 Implantable cardioverter defibrillator Lead failure Defibrillation testing Riata™ lead Externalized conductors
下载PDF
Externalized conductors and insulation failure in Biotronik defibrillator leads: History repeating or a false alarm?
2
作者 Elia De Maria Ambra Borghi +2 位作者 Lorenzo Bonetti pier luigi fontana Stefano Cappelli 《World Journal of Clinical Cases》 SCIE 2017年第2期27-34,共8页
Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator(ICD) leads. Conductor externalization is a "unique"... Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator(ICD) leads. Conductor externalization is a "unique" failure mechanism: Cables externalize through the insulation("inside-out" abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction(not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a nonprospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries(GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads. 展开更多
关键词 IMPLANTABLE cardioverter DEFIBRILLATOR Biotronik IMPLANTABLE cardioverter DEFIBRILLATOR LEAD Externalized CONDUCTORS INSULATION failure