期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
The role of photovaporization of the prostate in small volume benign prostatic hyperplasia and review of the literature 被引量:6
1
作者 Dominique Thomas Kevin C.Zorn +6 位作者 Malek Meskawi Ramy Goueli pierre-alain hueber Lesa Deonarine Vincent Misrai Alexis Te Bilal Chughtai 《Asian Journal of Urology》 CSCD 2019年第4期353-358,共6页
Objective:Our objective was to characterize the safety and efficacy of the 180 W XPS-GreenLight laser in men with lower urinary tract symptoms secondary to a small volume benign prostatic hyperplasia(BPH).Methods:A re... Objective:Our objective was to characterize the safety and efficacy of the 180 W XPS-GreenLight laser in men with lower urinary tract symptoms secondary to a small volume benign prostatic hyperplasia(BPH).Methods:A retrospective analysis was performed for all patients who underwent 180 W XPSlaser photoselective vaporization of the prostate(PVP)vaporization of the prostate between 2012 and 2016 at two-tertiary medical centers.Data collection included baseline comorbidities,disease-specific quality of life scores,maximum urinary flow rate(Qmax),postvoid residual(PVR),complications,prostate volume and prostate-specific antigen(PSA).The secondary endpoints were the incidence of intraoperative and postoperative adverse events.Complications were stratified using the Clavien-Dindo grading system up to 90 days after surgery.Results:Mean age of men was 67.8 years old,with a mean body mass index of 29.7 kg/m2.Mean prostate volume as measured by transrectal ultrasound was 29 mL.Anticoagulation use was 47%and urinary retention with catheter at time of surgery was 17%.Mean hospital stay and catheter time were 0.5 days.Median follow-up time was 6 months with the longest duration of follow-up being 22.5 months(interquartile range,3-22.5 months).The International Prostate Symptom Score improved from 22.8±7.0 at baseline to 10.7±7.4(p<0.01)and 6.3±4.4(p<0.01)at 1 and 6 months,respectively.The Qmax improved from 7.70±4.46 mL/s at baseline to 17.25±9.30 mL/s(p<0.01)and 19.14±7.19 mL/s(p<0.001)at 1 and 6 months,respectively,while the PVR improved from 216.0±271.0 mL preoperatively to 32.8±45.3 mL(p<0.01)and 26.2±46.0 mL(p<0.01)at 1 and 6 months,respectively.The PSA dropped from 1.97±1.76 ng/mL preoperatively to 0.71±0.61 ng/mL(p<0.01)and 0.74±0.63 ng/mL at 1 and 6 months,respectively.No patient had a bladder neck contracture postoperatively and no capsular perforations were noted intraoperatively.Conclusion:The 180 W GreenLight XPS system is safe and effective for men with small volume BPH.PVP produced improvements in symptomatic and clinical parameters without any safety concern.It represents a safe surgical option in this under studied population. 展开更多
关键词 Benign prostatic hyperplasia Photovaporization of the prostate GreenLight XPS Lower urinary tract symptoms Small prostate
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部