Currently approved vaccines have been successful in preventing the severity of COVID-19 and hospitalization. These vaccines primarily induce humoral immune responses;however, highly transmissible and mutated variants,...Currently approved vaccines have been successful in preventing the severity of COVID-19 and hospitalization. These vaccines primarily induce humoral immune responses;however, highly transmissible and mutated variants, such as the Omicron variant, weaken the neutralization potential of the vaccines, thus,raising serious concerns about their efficacy. Additionally, while neutralizing antibodies(nAbs) tend to wane more rapidly than cell-mediated immunity, long-lasting T cells typically prevent severe viral illness by directly killing infected cells or aiding other immune cells. Importantly, T cells are more cross-reactive than antibodies, thus, highly mutated variants are less likely to escape lasting broadly cross-reactive T cell immunity. Therefore, T cell antigen-based human coronavirus(HCoV) vaccines with the potential to serve as a supplementary weapon to combat emerging SARS-CoV-2 variants with resistance to n Abs are urgently needed. Alternatively, T cell antigens could also be included in B cell antigen-based vaccines to strengthen vaccine efficacy. This review summarizes recent advancements in research and development of vaccines containing T cell antigens or both T and B cell antigens derived from proteins of SARS-CoV-2 variants and/or other HCo Vs based on different vaccine platforms.展开更多
Objective: To introduce and characterize the modified biplanar opening high tibial osteotomy with rigid fixation to treat varus knee in young and active patients. Methods: Between June 2001 to July 2008, 18 patients...Objective: To introduce and characterize the modified biplanar opening high tibial osteotomy with rigid fixation to treat varus knee in young and active patients. Methods: Between June 2001 to July 2008, 18 patients with monocompartmental degeneration of the knee combined with a varus malalignment of the leg had the modified biplanar opening high tibial osteotomy and the osteotomy was fixed with the locking plates (Locking Compression Plate System). The mean varus deformity before operation was 11.5° (5°- 19°) and no degenerative changes were found in other departments. Stability of the knee was normal in 15 patients, but ruptures in anterior cruciate ligaments or lateral collateral ligament were presented in the remaining 3 patients. Preoperative symptom was mainly limited in the pain of medial compartment. The preoperative and follow-up data for the range of motion and Lysholm score were determined. Subjective satisfactory examination was also applied to the patients for the operation they selected. Results: All of the patients were followed up with an average of 32.5 months (12-82 months). There was no ununion or delayed union in this group during the follow-up period. No complications like broken plate, nerve injury, or blood vessel injury occurred. The postoperative average corrected degree was 9.5° (5.5°-18°). No degenerations developed in the three departments of the knee. The Lysholm scores before and after surgery were 42.5 and 77.5, respectively (P〈0.01). The overall fineness rate was 83.3%. The subjective satisfactory survey demonstrated that about 83.3% patients showed satisfactory on the operation. There was no obvious difference in the range of motion before and after operation, but significant changes were found in the Lysholm score and varus degree from preoperative to follow-up. Conclusion: Proximal opening high tibial osteotomy performed in conjunction with the special rigid locking plate yielded good results for symptomatic genu varum. This new classic technique can be effectively applied to the medial compartment degeneration of the knee in active young patients.展开更多
基金supported by the National Key Research and Development Program of China (2023YFC2307800)Chengdu University of Traditional Chinese Medicine (030040018)+2 种基金Shanghai Municipal Science and Technology Major Project (ZD2021CY001)National Natural Science Foundation of China (32270142)Shanghai Rising-Star Program (22QA1408800)。
文摘Currently approved vaccines have been successful in preventing the severity of COVID-19 and hospitalization. These vaccines primarily induce humoral immune responses;however, highly transmissible and mutated variants, such as the Omicron variant, weaken the neutralization potential of the vaccines, thus,raising serious concerns about their efficacy. Additionally, while neutralizing antibodies(nAbs) tend to wane more rapidly than cell-mediated immunity, long-lasting T cells typically prevent severe viral illness by directly killing infected cells or aiding other immune cells. Importantly, T cells are more cross-reactive than antibodies, thus, highly mutated variants are less likely to escape lasting broadly cross-reactive T cell immunity. Therefore, T cell antigen-based human coronavirus(HCoV) vaccines with the potential to serve as a supplementary weapon to combat emerging SARS-CoV-2 variants with resistance to n Abs are urgently needed. Alternatively, T cell antigens could also be included in B cell antigen-based vaccines to strengthen vaccine efficacy. This review summarizes recent advancements in research and development of vaccines containing T cell antigens or both T and B cell antigens derived from proteins of SARS-CoV-2 variants and/or other HCo Vs based on different vaccine platforms.
基金Project (No. 30801167) supported by the National Natural Science Foundation of China
文摘Objective: To introduce and characterize the modified biplanar opening high tibial osteotomy with rigid fixation to treat varus knee in young and active patients. Methods: Between June 2001 to July 2008, 18 patients with monocompartmental degeneration of the knee combined with a varus malalignment of the leg had the modified biplanar opening high tibial osteotomy and the osteotomy was fixed with the locking plates (Locking Compression Plate System). The mean varus deformity before operation was 11.5° (5°- 19°) and no degenerative changes were found in other departments. Stability of the knee was normal in 15 patients, but ruptures in anterior cruciate ligaments or lateral collateral ligament were presented in the remaining 3 patients. Preoperative symptom was mainly limited in the pain of medial compartment. The preoperative and follow-up data for the range of motion and Lysholm score were determined. Subjective satisfactory examination was also applied to the patients for the operation they selected. Results: All of the patients were followed up with an average of 32.5 months (12-82 months). There was no ununion or delayed union in this group during the follow-up period. No complications like broken plate, nerve injury, or blood vessel injury occurred. The postoperative average corrected degree was 9.5° (5.5°-18°). No degenerations developed in the three departments of the knee. The Lysholm scores before and after surgery were 42.5 and 77.5, respectively (P〈0.01). The overall fineness rate was 83.3%. The subjective satisfactory survey demonstrated that about 83.3% patients showed satisfactory on the operation. There was no obvious difference in the range of motion before and after operation, but significant changes were found in the Lysholm score and varus degree from preoperative to follow-up. Conclusion: Proximal opening high tibial osteotomy performed in conjunction with the special rigid locking plate yielded good results for symptomatic genu varum. This new classic technique can be effectively applied to the medial compartment degeneration of the knee in active young patients.