Validation and reproducibility of the Heidelberg Edge Perimeter in the detection of glaucomatous visual field defects
1
作者 Qi N.Cui priyanka gogt +5 位作者 Jonathan M.Lam Safa Siraj Lisa A.Hark Jonathan S.Myers L.Jay Katz Michael Waisbourd 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第4期577-581,共5页
AIM: To validate the ability of the Heidelberg Edge Perimeter(HEP) in detecting glaucomatous visual field(VF) defects compared to the Octopus Visual Field(OVF) Analyzer and to determine the test-retest repeatability o... AIM: To validate the ability of the Heidelberg Edge Perimeter(HEP) in detecting glaucomatous visual field(VF) defects compared to the Octopus Visual Field(OVF) Analyzer and to determine the test-retest repeatability of both modalities.METHODS: This prospective, cross-sectional study was conducted at Wills Eye Hospital, Philadelphia, PA. Glaucoma subjects and unaffected controls underwent VF testing using HEP standard automated perimetry(SAP) Ⅲ 30-2 Adaptive Staircase Thresholding Algorithm(ASTA) FAST protocol and OVF G-TOP white-on-white strategy. Testing order was randomized. Pearson's correlation coefficient was calculated for both mean deviation(MD) and pattern standard deviation/square root of loss of variance(PSD/s LV). Receiver operating characteristic(ROC) curves were used to determine the diagnostic abilities of both modalities. Glaucoma subjects returned for repeat testing and intraclass correlation coefficients(ICCs) were calculated to assess test-retest repeatability. RESULTS: Seventy-nine subjects with glaucoma and 36 unaffected controls were enrolled. HEP and OVF were significantly correlated for both MD(r=-0.84; P<0.01) and PSD/s LV(r=0.79; P<0.01). Areas under the ROC curves(AUCs) were also comparable between HEP and OVF for both MD(0.74 and 0.79, respectively; P=0.26) and PSD/sL V(0.74 and 0.82; P=0.08). ICC was high for both HEP (0.96 for MD, 0.95 for PSD/s LV) and OVF(0.82 and 0.88, respectively). Mean test duration(min) was significantly shorter for OVF(2.63) compared to HEP(5.15; P<0.01). CONCLUSION: HEP and OVF show strong correlation for both MD and PSD/s LV, and have similar validity for detecting glaucoma. The test-retest repeatability is high for both HEP and OVF, however the average testing duration of HEP is significantly longer than that of OVF. 展开更多
关键词 glaucoma HEIDELBERG EDGE PERIMETER standard automated PERIMETRY Octopus VISUAL FIELD Analyzer VISUAL FIELD
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部