This letter reports a chemiluminescene immunoassay method combined with immunomagnetic separation to rapidly detect Cyfra 21-1, in which bio-functionlized magnetic nanocomposites were used as mobile substrate for capt...This letter reports a chemiluminescene immunoassay method combined with immunomagnetic separation to rapidly detect Cyfra 21-1, in which bio-functionlized magnetic nanocomposites were used as mobile substrate for capturing and isolating the cyfra 21-1 proteins. After the captured Cyfra 21-1 further reacted with horseradish peroxidase-conjugated anti-Cyfra 21-1 antibody to form a sandwich immunocomplex, the chemiluminescence would be produced as a result of addition of the chemiluminescent substrate. A home-made optical biosensor was designed to detect the chemiluminescence instead of other large instruments. There is a good linear response between the chemiluminescence intensity and the concentration of Cyfra 21-1 in the range from 0.2 to 50 ng/mL. The whole detection process including incubation, washing and detection could be performed within 45 min. The proposed method offers a simple, noninvasive and reliable tool for detecting non-small cell lung cancer and has potential application for clinical testing.展开更多
基金supported by the National Natural Science Foundation of China (61125105, 61101048, 61002037, 61027001)the Major National Scientific Research Plan (2011CB933202)the"Strategic Priority Research Program"of the Chinese Academy of Sciences (XDA06020101)
文摘This letter reports a chemiluminescene immunoassay method combined with immunomagnetic separation to rapidly detect Cyfra 21-1, in which bio-functionlized magnetic nanocomposites were used as mobile substrate for capturing and isolating the cyfra 21-1 proteins. After the captured Cyfra 21-1 further reacted with horseradish peroxidase-conjugated anti-Cyfra 21-1 antibody to form a sandwich immunocomplex, the chemiluminescence would be produced as a result of addition of the chemiluminescent substrate. A home-made optical biosensor was designed to detect the chemiluminescence instead of other large instruments. There is a good linear response between the chemiluminescence intensity and the concentration of Cyfra 21-1 in the range from 0.2 to 50 ng/mL. The whole detection process including incubation, washing and detection could be performed within 45 min. The proposed method offers a simple, noninvasive and reliable tool for detecting non-small cell lung cancer and has potential application for clinical testing.