Beamline BL17 U1 at Shanghai Synchrotron Radiation Facility is an energy-tunable macromolecular crystallography beamline that has been in user operation since 2009. Growing demand from the user community for a small b...Beamline BL17 U1 at Shanghai Synchrotron Radiation Facility is an energy-tunable macromolecular crystallography beamline that has been in user operation since 2009. Growing demand from the user community for a small beam and related experimental methods have motivated upgrades of the devices in the endstation.Minibeam modes have already been developed for operation. A self-integrated diffractometer reduces the sphere of confusion of the rotatory axis to 1μm. The new diffractometer is equipped with an upgraded on-axis viewing system that can improve the resolving power. Additionally,the area detector was also upgraded to the newest generation of detectors, the EIGER X 16 M, which can collect data at 133 Hz. After these upgrades, the endstation became virtually new. This paper covers the upgrade of the endstation devices and gives the first data collection results.展开更多
Data collection with microcrystals at synchrotron radiation facilities is challenging because it is difficult to harvest and locate microcrystals. Moreover,microcrystals are sensitive to radiation damage; thus, typica...Data collection with microcrystals at synchrotron radiation facilities is challenging because it is difficult to harvest and locate microcrystals. Moreover,microcrystals are sensitive to radiation damage; thus, typically, a complete data set cannot be obtained with a single microcrystal. Herein, we report a new method for data collection with multiple microcrystals having a crystal size ranging from 1 to 30 lm. This method is suitable for not only low-temperature(100 K) data collection but also room-temperature data collection. Thin Kapton membranes were used to capture multiple crystals simultaneously. The microcrystals were visible under an optical microscope and easily located because the membrane was transparent and sufficiently thin. The film was fixed to a bracket that was prepared using a three-dimensional printer. The bracket was fixed on a magnetic base via screwing and employed by the goniometer system for data collection. Multiple data sets of fatty acid-binding protein 4(FABP4) and lysozyme microcrystals were collected using this novel designed device. Finally, the structures of protein FABP4 and lysozyme were obtained from these data via the molecule replacement method. The data statistics reveal that this method provides a comparable result to traditional methods such as a nylon loop.展开更多
基金supported by the Maintenance and Renovation Project for the major infrastructure of the Chinese Academy of Sciencesthe Operation Project of SSRF
文摘Beamline BL17 U1 at Shanghai Synchrotron Radiation Facility is an energy-tunable macromolecular crystallography beamline that has been in user operation since 2009. Growing demand from the user community for a small beam and related experimental methods have motivated upgrades of the devices in the endstation.Minibeam modes have already been developed for operation. A self-integrated diffractometer reduces the sphere of confusion of the rotatory axis to 1μm. The new diffractometer is equipped with an upgraded on-axis viewing system that can improve the resolving power. Additionally,the area detector was also upgraded to the newest generation of detectors, the EIGER X 16 M, which can collect data at 133 Hz. After these upgrades, the endstation became virtually new. This paper covers the upgrade of the endstation devices and gives the first data collection results.
基金supported by the Strategic Priority Research program of the Chinese Academy of Sciences(No.XDB08030101)
文摘Data collection with microcrystals at synchrotron radiation facilities is challenging because it is difficult to harvest and locate microcrystals. Moreover,microcrystals are sensitive to radiation damage; thus, typically, a complete data set cannot be obtained with a single microcrystal. Herein, we report a new method for data collection with multiple microcrystals having a crystal size ranging from 1 to 30 lm. This method is suitable for not only low-temperature(100 K) data collection but also room-temperature data collection. Thin Kapton membranes were used to capture multiple crystals simultaneously. The microcrystals were visible under an optical microscope and easily located because the membrane was transparent and sufficiently thin. The film was fixed to a bracket that was prepared using a three-dimensional printer. The bracket was fixed on a magnetic base via screwing and employed by the goniometer system for data collection. Multiple data sets of fatty acid-binding protein 4(FABP4) and lysozyme microcrystals were collected using this novel designed device. Finally, the structures of protein FABP4 and lysozyme were obtained from these data via the molecule replacement method. The data statistics reveal that this method provides a comparable result to traditional methods such as a nylon loop.