AIM: To study the effect of an innovative micro-dissection procedure by radiofrequency ablation (MRA) in removing eyelid nevus.METHODS: Fifty-six consecutive outpatients with eyelid nevus were treated with MRA using a...AIM: To study the effect of an innovative micro-dissection procedure by radiofrequency ablation (MRA) in removing eyelid nevus.METHODS: Fifty-six consecutive outpatients with eyelid nevus were treated with MRA using a monopolar device. The effect of MRA was determined after following-up for 6mo to 5y.RESULTS: Fifty-two cases (52 eyes, 92.9%) were cured once, and 4 cases (4 eyes, 7.1%) received second treatment for small residual. All cases healed well after surgery, with no pigmentation, no scars, no loss of eyelashes, no deformation of eyelid margin. There was no visual impairment after healing.CONCLUSION: MRA of eyelid nevus using the XL-RFA device is highly efficient without significant complications.展开更多
We present a new event mixing technique for measuring two-pion Bose-Einstein correlations (BEC) in reactions with only two identical bosons among three final state particles. This new mixing method contains a missin...We present a new event mixing technique for measuring two-pion Bose-Einstein correlations (BEC) in reactions with only two identical bosons among three final state particles. This new mixing method contains a missing mass consistency (MMC) cut and an energy sum order (ESO) cut. Unlike the previous proposed pion energy cut, which abandons nearly half the original events, the ESO cut does not eliminate any original events and hence improves the statistics of both original events and mixed events. Numerical tests using the γp→π0π0p events around 1 GeV are carried out to verify the validity of the ESO cut. This cut is able to reproduce the relative momentum distribution of the original events in the absence of BEC effects. In addition, its ability to observe BEC effects is tested by an event sample in the presence of BEC effects. Simulation results show the BEC effects can be observed clearly as an enhancement in the correlation function, and the BEC parameters extracted by this event mixing cut are consistent with the input BEC parameters.展开更多
基金Supported by Health Department of GeneralLogistics(No.413F261N)
文摘AIM: To study the effect of an innovative micro-dissection procedure by radiofrequency ablation (MRA) in removing eyelid nevus.METHODS: Fifty-six consecutive outpatients with eyelid nevus were treated with MRA using a monopolar device. The effect of MRA was determined after following-up for 6mo to 5y.RESULTS: Fifty-two cases (52 eyes, 92.9%) were cured once, and 4 cases (4 eyes, 7.1%) received second treatment for small residual. All cases healed well after surgery, with no pigmentation, no scars, no loss of eyelashes, no deformation of eyelid margin. There was no visual impairment after healing.CONCLUSION: MRA of eyelid nevus using the XL-RFA device is highly efficient without significant complications.
基金Supported by Fundamental Research Funds for the Central Universities(1006-YAH17063,1006-XAA18059)
文摘We present a new event mixing technique for measuring two-pion Bose-Einstein correlations (BEC) in reactions with only two identical bosons among three final state particles. This new mixing method contains a missing mass consistency (MMC) cut and an energy sum order (ESO) cut. Unlike the previous proposed pion energy cut, which abandons nearly half the original events, the ESO cut does not eliminate any original events and hence improves the statistics of both original events and mixed events. Numerical tests using the γp→π0π0p events around 1 GeV are carried out to verify the validity of the ESO cut. This cut is able to reproduce the relative momentum distribution of the original events in the absence of BEC effects. In addition, its ability to observe BEC effects is tested by an event sample in the presence of BEC effects. Simulation results show the BEC effects can be observed clearly as an enhancement in the correlation function, and the BEC parameters extracted by this event mixing cut are consistent with the input BEC parameters.