期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Al-Zn-Mg合金厚板多层多道TIG焊接接头的显微组织与冲击力学性能(英文) 被引量:7
1
作者 郜庆伟 舒凤远 +1 位作者 何鹏 杜文博 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2019年第12期2496-2505,共10页
研究Al-Zn-Mg合金厚板多层多道TIG焊接接头的显微组织和冲击力学性能。通过扫描电子显微镜(SEM)、X射线衍射(XRD)、透射电子显微镜(TEM)和能量色散谱(EDS)对焊接接头不同区域的相组成和显微组织进行表征,同时对其进行冲击力学性能测试... 研究Al-Zn-Mg合金厚板多层多道TIG焊接接头的显微组织和冲击力学性能。通过扫描电子显微镜(SEM)、X射线衍射(XRD)、透射电子显微镜(TEM)和能量色散谱(EDS)对焊接接头不同区域的相组成和显微组织进行表征,同时对其进行冲击力学性能测试。结果表明:焊缝中产生弥散分布的球状和针状η(MgZn2)相。焊接热影响区的物相组成为α(Al)+η(MgZn2)+Al6Mn,并存在大量弥散分布的纳米级沉淀颗粒。焊接接头焊缝区冲击韧度最高,焊接接头焊缝区中的MgZn2相有利于接头韧性的提高。焊接热影响区中Al2MgCu相在断裂过程中起到裂纹源的作用。 展开更多
关键词 AL-ZN-MG合金 厚板 多层TIG焊接 显微组织 冲击力学性能
下载PDF
Bayesian-Based Speckle Suppression for SAR Image Using Contourlet Transform 被引量:1
2
作者 De-Xiang Zhang qing-wei gao Xiao-Pei Wu 《Journal of Electronic Science and Technology of China》 2008年第1期79-82,共4页
A novel and efficient speckle noise reduction algorithm based on Bayesian contourlet shrinkage using contourlet transform is proposed.First,we show the sub-band decompositions of SAR images using contourle transforms,... A novel and efficient speckle noise reduction algorithm based on Bayesian contourlet shrinkage using contourlet transform is proposed.First,we show the sub-band decompositions of SAR images using contourle transforms,which provides sparse representation at both spatial and directional resolutions.Then,a Bayesian contourlet shrinkage factor is applied to the decomposed data to estimate the best value for noise-free contourle coefficients.Experimental results show that compared with conventional wavelet despeckling algorithm,the proposed algorithm can achieve an excellent balance between suppresses speckle effectively and preserve image details,and the significant information of origina image like textures and contour details is well ma intained. 展开更多
关键词 Bayesian shrinkage contourlet transform despeckling SAR image.
下载PDF
An Immunoabsorption Column Configuration for Hepatitis B Virus
3
作者 qing-wei gao Han-fa Zou +1 位作者 Liang Kong De-sheng Yuan 《国际感染病学(电子版)》 CAS 2013年第3期110-113,共4页
Objective To conifgure an immunoabsorption column for hepatitis B virus. Methods Being activated by epichlorohydrin, the human antibody HBsAb-IgG was bound to the carrier of agarose gel. The configuration process was... Objective To conifgure an immunoabsorption column for hepatitis B virus. Methods Being activated by epichlorohydrin, the human antibody HBsAb-IgG was bound to the carrier of agarose gel. The configuration process was as follows: the synthesis of epoxide matrix, the synthesis and activation of amino matrix, the synthesis of aldehydic matrix, the synthesis of immunoabsorption matrix, the end capping and reduction of unbound aldehydic, the blocking of unbound mass and the iflling of the column. Results The bound rate of activated agarose gel and antibody HBsAb-IgG is 85.07%. By plasma adsorption experiment, it is revealed that the immunoabsorption column can absorb and eliminate 58.97%of HBsAg and 53.1%of hepatitis B virus particles in extracorporeal plasma. Conclusions The immunoabsorption column for hepatitis B virus can absorb and eliminate HBsAg and hepatitis B virus particles in extracorporeal plasma. 展开更多
关键词 Hepatitis B virus SEPHAROSE HBsAb-IgG LINKAGE Immunoabsorption
下载PDF
Clinical Characteristics and Treatment for Patients with Occult Chronic Hepatitis B
4
作者 qing-wei gao De-sheng Yuan 《国际感染病学(电子版)》 CAS 2013年第1期25-28,共4页
Objective To observe the clinical manifestations and assess direct antiviral effect for patients with occult hepatitis B in China.Methods The study includes 15 patients with occult hepatitis B and their medical histor... Objective To observe the clinical manifestations and assess direct antiviral effect for patients with occult hepatitis B in China.Methods The study includes 15 patients with occult hepatitis B and their medical history,family history,firstdiagnosis time,confirmed-diagnosis time,laboratory report,anti-viral therapy and outcomes were analyzed.Results The average age of the patients is 38.67-year old(6 males and 9 females),2 with acute hepatitis B(2/15,13.3%),13 with no hepatitis history(13/15,86.6%),8 with family history(8/15,53.3%),6 with no family history(6/15,40%),1 with unknown family history(1/15,6.6%).Eight patients were treated with entecavir(0.5 mg/day,taken orally),with effective results and steady conditions;3 patients were treated with lamivudine(0.1 g/day,taken orally),2 of them were prescribed to take adefovir dipivoxil additionally due to drug-resistance,the other one was treated with lamivudine continuously without drug-resistance;4 cases refused anti-viral therapy.One patient’s condition remained steady,1 patient died of cirrhosis with portal hypertension and liver failure 5 years after firstdiagnosis,1 patient progressed to hepatocellular carcinoma and accepted surgery operation treatment 5 years after first-diagnosis,the other 1 patient progressed to compensatory cirrhosis 2 years after first-diagnosis and is steady from then,which indicates that occult chronic hepatitis B can progress to cirrhosis and hepatocellular carcinoma without therapy in time.Conclusions The clinical characteristics of 15 cases with occult chronic hepatitis B showed that these patients with short latency,younger age when being-struck,and light damage to liver function.The efficacy and drugresistance of nucleos(t)ide-analogue(entecavir,lamivudine,adefovir dipivoxil)in treatment of patients with occult chronic hepatitis B are similar to chronic hepatitis B. 展开更多
关键词 OCCULT Chronic hepatitis B Clinical course TREATMENT
下载PDF
Medical X-Ray Image Enhancement Based on Kramer's PDE Model
5
作者 Yan-Fei Zhao qing-wei gao +1 位作者 De-Xiang Zhang Yi-Xiang Lu 《Journal of Electronic Science and Technology of China》 2007年第2期187-190,共4页
The purpose of this study is to present an application of a novel enhancement technique for enhancing medical images generated from X-rays. The method presented in this study is based on a nonlinear partial differenti... The purpose of this study is to present an application of a novel enhancement technique for enhancing medical images generated from X-rays. The method presented in this study is based on a nonlinear partial differential equation (PDE) model, Kramer's PDE model. The usefulness of this method is investigated by experimental results. We apply this method to a medical X-ray image. For comparison, the X-ray image is also processed using classic Perona-Malik PDE model and Catte PDE model. Although the Perona-Malik model and Catte PDE model could also enhance the image, the quality of the enhanced images is considerably inferior compared with the enhanced image using Kramer's PDE model. The study suggests that the Kramer's PDE model is capable of enhancing medical X-ray images, which will make the X-ray images more reliable. 展开更多
关键词 Terms-Enhancement nonlinear partial differential equation (PDE) partial differential equation model X-ray image.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部