期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Biomechanical Study on the Novel Biomimetic Hemi-Pelvis Prosthesis 被引量:3
1
作者 Zikai Hua Yongwei Fan +1 位作者 qinghong cao Xianbo Wu 《Journal of Bionic Engineering》 SCIE EI CSCD 2013年第4期506-513,共8页
A pelvic endoprosthesis is the primary means of pelvic reconstruction after internal hemipelvectomy. In this study, a novel biomimetic hemipelvic prosthesis, including an artificial ilium, an artificial acetabulum, an... A pelvic endoprosthesis is the primary means of pelvic reconstruction after internal hemipelvectomy. In this study, a novel biomimetic hemipelvic prosthesis, including an artificial ilium, an artificial acetabulum, and an artificial pubis, was developed. A Finite Element Method (FEM) was carried out to investigate the biomechanical performance of a pelvis reconstructed with biomimetic hemipelvic prosthesis. Two models, including the reconstructed pelvis and the original pelvis (control model), were established according to the geometry from CT data of a human male patient with pelvic bone sarcomas. The FE models predict that the biomeehanical function of the pelvic ring can be reestablished using this prosthesis. Results show that the body force loaded on the S 1 vertebra is restored and transferred towards the sacro-iliac joint, and along the ilium onto the bearing surface of the artificial ilium, then to the artificial acetabulum and pubis. Von Mises stresses observed in this reconstructed pelvis model are still within a low and elastic range below the yielding strength of cortical bone and Ti6A14V. The values of deformation and strain of the reconstructed pelvis are close to the data obtained in the original pelvis. With the partial replacement of the pubis, little influence is found towards the pubis symphysis. However, the interface between the prosthesis and pelvic bone may become the critical part of the reconstructed pelvis due to the discontinuity in the material properties, which results in stress shielding and deformation constraining. So a biomimetic flexible connection or inter layer to release the deformation of pelvis is suggested in future designing. 展开更多
关键词 biomimetic prosthesis pelvic reconstruction BIOMECHANICS FEM
原文传递
Measuring relic abundance of minimal dark matter at hadron colliders
2
作者 qinghong cao Ti Gong +1 位作者 KePan Xie Zhen Zhang 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS CSCD 2019年第8期55-74,共20页
We consider the special case that the dark matter(DM) candidate is not detected in direct-detection programs when the experimental sensitivity reaches the neutrino flux background. In such circumstance the DM searches... We consider the special case that the dark matter(DM) candidate is not detected in direct-detection programs when the experimental sensitivity reaches the neutrino flux background. In such circumstance the DM searches at the colliders impose constraints on the DM relic abundance if the DM candidate is a WIMPs type. Specifically, we consider the triplet(quintet and septet) DMs in the framework of minimal DM model and explore the potential of discovering the DM candidate in the mono-jet, mono-photon and vector boson fusion channels at the Large Hadron Collider(LHC) and future 100 TeV hadron collider. If the DM candidate in such a scenario is discovered at the LHC, then additional DM candidates are needed to explain the observed relic abundance.On the other hand, null results in those DM searching programs at the colliders give rise to lower limits of DM relic abundance. 展开更多
关键词 DARK MATTER electro weak interactions HADRON COLLIDERS
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部