期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Characteristic Analysis of Power Oscillations Caused by Disharmony Among Voltage-source-controlled Units in Three-terminal Local Power Grid
1
作者 qiyi yu Yi Tang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第4期1295-1308,共14页
Previous studies have demonstrated that disharmony among voltage-source-controlled units(VSCUs)may occur on an alternating current(AC)transmission or distribution line under steady-state operating conditions(SSOCs)or ... Previous studies have demonstrated that disharmony among voltage-source-controlled units(VSCUs)may occur on an alternating current(AC)transmission or distribution line under steady-state operating conditions(SSOCs)or quasistatic operating conditions(QSSOCs).As the studies on frequency disharmony have been expanded to multiple disharmonized vS-CUs in the local power grid,its adverse effects on AC lines and equivalent load(EL)at the bus without active voltage control ability(non-active bus)need to be investigated further.Considering the locality of disharmony and common topological con-nections among VSCUs,this paper adopts a Y-type three-termi-nal local power grid(LPG)as the research object.The disharmony among the three VSCUs is discussed.Firstly,for the load at non-active bus,the formulas for single-phase instantaneous voltage,load current,load power,as well as average power un-der disharmony operating conditions(DOCs)are derived.The characteristic indicators of the above electrical quantities are defined,which can measure the amplification and reduction de-grees of the above electrical quantities before and after disharmony.Secondly,for the line directly connected to VSCUs,the formulas for single-phase instantaneous line current and power and the average power under DOCs are derived.The characteristic indicators of power flow are defined,which can be used to quantify the peak amplification impact of oscillation before and after disharmony.Finally,the case study on the Y-type three-terminal LPG under the single-disharmony and the multi-dis-harmony switching scenarios indicates that the long-period pow-er oscillation caused by disharmony may occur in the load flow at the non-active bus and the line flow.The oscillation causes a serious decrease in load capability and a significant amplification of the peak of line power oscillation. 展开更多
关键词 New power system power oscillation disharmony voltage-source-controlled unit(VSCU) characteristic analysis
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部