AIM:To analyze the correlation of Goldmann applanation tonometer(GAT),I-Care tonometer and Tono-Pen tonometer results in young healthy persons,and to investigate the influence of central corneal thickness(CCT)on ...AIM:To analyze the correlation of Goldmann applanation tonometer(GAT),I-Care tonometer and Tono-Pen tonometer results in young healthy persons,and to investigate the influence of central corneal thickness(CCT)on intraocular pressure(IOP)measurements recorded with these tonometers.·M ETHODS:We conducted a pilot clinical study in 78eyes of 78 subjects aged 22-28 years old(44 women and34 men;mean age 23.8±1.19y).IOP was measured using GAT,I-Care and Tono-Pen tonometers,followed by measurements of CCT.Statistical analysis was performed using SPSS 20.0.·RESULTS:The mean IOPs and standard deviation(±SD)for GAT,I-Care and Tono-Pen were 15.62±2.281 mm Hg,16.29±2.726 mm Hg and 16.32±2.393 mm Hg,respectively.The mean CCT was 555.15±29.648μm.Clear positive correlations between GAT and I-Care,GAT and TonoPen,and I-Care and Tono-Pen tonometers were found(=0.867,〈0.001;=0.861,〈0.001;=0.915,〈0.001,respectively).In comparison between devices,BlandAltman analysis showed a significant mean difference(MD)in the measurements by GAT and I-Care of-0.679 mm Hg and by GAT and Tono-Pen of-0.705 mm Hg(〈0.001),but there was no significant difference between I-Care and Tono-Pe(〉0.05).Both non-gold standard tonometers were affected by CCT;that is,both I-Care and Tono-Pen tonometer values were significantly higher with higher CCT means(〉555μm;MD=-1.282,〈0.001;MD=-0.949,〈0.001,respectively)compared with GAT.·CONCLUSION:Both I-Care and Tono-Pen tonometers overestimated IOP compared with the GAT values.Either the I-Care or Tono-Pen tonometer could be used instead of GAT because there was no significant difference between their results.Higher CCT values(〉555μm)were associated with overestimated IOP values.展开更多
Juvenile X-linked retinoschisis(XLRS, MIM#312700) belongs to a group of the vitreoretinal dystrophies. We aimed to describe the phenotype-genotype correlation of three XLRS cases in juveniles with different novel mu...Juvenile X-linked retinoschisis(XLRS, MIM#312700) belongs to a group of the vitreoretinal dystrophies. We aimed to describe the phenotype-genotype correlation of three XLRS cases in juveniles with different novel mutations from the Lithuanian population. The patients demonstrated macular retinoschisis and typical cyst-like cavities on spectral-domain optical coherence tomography(SD-OCT) images. The mean central foveal thickness was 569.7 μm. Two patients presented with peripheral retinoschisis. Flash electroretinogram demonstrated a reduced b/a ratio(〈1.0) in all patients. RS1(NM_000330.3) gene coding exons Sanger sequencing was performed. RS1 c.599 G〉T(p.R200 L) mutation was detected in one case, showing to be pathogenic in silico analysis. c.(92_97) ins C(p.W33 fs) mutation was identified for another patient, indicating the variant is possibly damaging in silico analysis. The third case was identified with a pathogenic mutation c.422 C〉G(p.R141 H), HGMD CM981753. These are the first cases of XLRS in the Lithuanian population confirmed by molecular genotyping. Presented patients had a different genotype but similar phenotypic traits.展开更多
文摘AIM:To analyze the correlation of Goldmann applanation tonometer(GAT),I-Care tonometer and Tono-Pen tonometer results in young healthy persons,and to investigate the influence of central corneal thickness(CCT)on intraocular pressure(IOP)measurements recorded with these tonometers.·M ETHODS:We conducted a pilot clinical study in 78eyes of 78 subjects aged 22-28 years old(44 women and34 men;mean age 23.8±1.19y).IOP was measured using GAT,I-Care and Tono-Pen tonometers,followed by measurements of CCT.Statistical analysis was performed using SPSS 20.0.·RESULTS:The mean IOPs and standard deviation(±SD)for GAT,I-Care and Tono-Pen were 15.62±2.281 mm Hg,16.29±2.726 mm Hg and 16.32±2.393 mm Hg,respectively.The mean CCT was 555.15±29.648μm.Clear positive correlations between GAT and I-Care,GAT and TonoPen,and I-Care and Tono-Pen tonometers were found(=0.867,〈0.001;=0.861,〈0.001;=0.915,〈0.001,respectively).In comparison between devices,BlandAltman analysis showed a significant mean difference(MD)in the measurements by GAT and I-Care of-0.679 mm Hg and by GAT and Tono-Pen of-0.705 mm Hg(〈0.001),but there was no significant difference between I-Care and Tono-Pe(〉0.05).Both non-gold standard tonometers were affected by CCT;that is,both I-Care and Tono-Pen tonometer values were significantly higher with higher CCT means(〉555μm;MD=-1.282,〈0.001;MD=-0.949,〈0.001,respectively)compared with GAT.·CONCLUSION:Both I-Care and Tono-Pen tonometers overestimated IOP compared with the GAT values.Either the I-Care or Tono-Pen tonometer could be used instead of GAT because there was no significant difference between their results.Higher CCT values(〉555μm)were associated with overestimated IOP values.
文摘Juvenile X-linked retinoschisis(XLRS, MIM#312700) belongs to a group of the vitreoretinal dystrophies. We aimed to describe the phenotype-genotype correlation of three XLRS cases in juveniles with different novel mutations from the Lithuanian population. The patients demonstrated macular retinoschisis and typical cyst-like cavities on spectral-domain optical coherence tomography(SD-OCT) images. The mean central foveal thickness was 569.7 μm. Two patients presented with peripheral retinoschisis. Flash electroretinogram demonstrated a reduced b/a ratio(〈1.0) in all patients. RS1(NM_000330.3) gene coding exons Sanger sequencing was performed. RS1 c.599 G〉T(p.R200 L) mutation was detected in one case, showing to be pathogenic in silico analysis. c.(92_97) ins C(p.W33 fs) mutation was identified for another patient, indicating the variant is possibly damaging in silico analysis. The third case was identified with a pathogenic mutation c.422 C〉G(p.R141 H), HGMD CM981753. These are the first cases of XLRS in the Lithuanian population confirmed by molecular genotyping. Presented patients had a different genotype but similar phenotypic traits.