AC currents are automatically calibrated by two different thermal current converter(TCC)designs.The two designs are different in the used number of the thermal-elements(TEs).Consequently they differ in their output el...AC currents are automatically calibrated by two different thermal current converter(TCC)designs.The two designs are different in the used number of the thermal-elements(TEs).Consequently they differ in their output electro motive force(EMF).Studying the effect of changing the output EMF is done in this paper through calibrating AC currents.5 mA and 5 A are accurately calibrated at different frequencies 55 Hz,1 kHz and10 kHz by the two TCCs.A comparison is made between the results to evaluate the effect of the output EMF value on the accuracy and the uncertainty of the low and higher AC current calibration.A LabVIEW program is designed for this accurate automatic calibration to overcome the problems of the manual calibration on the thermal converters.展开更多
A new system for measuring low-ohmic standard resistors through a dual current sources bridge is introduced.It is used for low resistance measurements from 1 mΩto 1Ωat 1∶1 ratio,which is suitable for the laboratori...A new system for measuring low-ohmic standard resistors through a dual current sources bridge is introduced.It is used for low resistance measurements from 1 mΩto 1Ωat 1∶1 ratio,which is suitable for the laboratories without cryogenic current comparators(CCC)or direct current comparators(DCC)bridges.Behavior of this bridge is evaluated by comparing its measured values with the unknown resistor values obtained by another method.The accuracy of the introduced bridge is in the level of 10-5 for the 1 mΩresistor,and in the level of 10-4 for the 10 mΩ,100 mΩand 1Ωresistors.Moreover,a dual voltage sources system for the measurement of DC standard resistors from 1 kΩto 100 MΩis also presented.In this system,a modification is made on the modified Wheatstone bridge to evaluate its performance by adding another digital multimeter to measure the ratio between the unknown and the standard resistors simultaneously.This bridge is verified by comparing the measured values of 10 kΩresistor obtained by the two methods with its actual value.The bridge accuracy is in the level of 10-6 except for the 1 kΩresistor,and the bridge asymmetry is also evaluated.It is found the asymmetry is in the level of 10-6 for the resistors from 10 kΩto 100 MΩand in the level of 10-5 for 1 kΩresistors.The introduced bridges operations are controlled by LabVIEW programs designed specially for this purpose,and the expanded uncertainty is also evaluated for all measurement results.展开更多
A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measur...A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measurements through ACDC transfer standards for the first time at the National Institute for standards(N IS)in Egypt.The implemented circuit of theautomatic AC-DC switch and its protection are presented in details.An AC voltage source is calibrated against DC voltagesource by using the demonstrated automatic switch as an application The calibrated voltage ranges are2V,6V,20V and60V as examples.The uncertainty budget is also evaluated for the calibrated values.展开更多
Current dependence and stability of the measured resistance value are very important for the accurate measurement of DC standard resistor. In this paper, the volt-ampere (V-I) measurement method has been applied ...Current dependence and stability of the measured resistance value are very important for the accurate measurement of DC standard resistor. In this paper, the volt-ampere (V-I) measurement method has been applied to study the current depend-ence of four different types of standard resistors. Diverse values are obtained through the investigation of their stability at dif-ferent currents. Therefore, the current dependence coefficient (CDC) can be determined for each one of the studied resistors. Research shows CDC depends on the applied current value, the measurement time and the resistor type, as clearly demonstra-ted in this research.展开更多
文摘AC currents are automatically calibrated by two different thermal current converter(TCC)designs.The two designs are different in the used number of the thermal-elements(TEs).Consequently they differ in their output electro motive force(EMF).Studying the effect of changing the output EMF is done in this paper through calibrating AC currents.5 mA and 5 A are accurately calibrated at different frequencies 55 Hz,1 kHz and10 kHz by the two TCCs.A comparison is made between the results to evaluate the effect of the output EMF value on the accuracy and the uncertainty of the low and higher AC current calibration.A LabVIEW program is designed for this accurate automatic calibration to overcome the problems of the manual calibration on the thermal converters.
文摘A new system for measuring low-ohmic standard resistors through a dual current sources bridge is introduced.It is used for low resistance measurements from 1 mΩto 1Ωat 1∶1 ratio,which is suitable for the laboratories without cryogenic current comparators(CCC)or direct current comparators(DCC)bridges.Behavior of this bridge is evaluated by comparing its measured values with the unknown resistor values obtained by another method.The accuracy of the introduced bridge is in the level of 10-5 for the 1 mΩresistor,and in the level of 10-4 for the 10 mΩ,100 mΩand 1Ωresistors.Moreover,a dual voltage sources system for the measurement of DC standard resistors from 1 kΩto 100 MΩis also presented.In this system,a modification is made on the modified Wheatstone bridge to evaluate its performance by adding another digital multimeter to measure the ratio between the unknown and the standard resistors simultaneously.This bridge is verified by comparing the measured values of 10 kΩresistor obtained by the two methods with its actual value.The bridge accuracy is in the level of 10-6 except for the 1 kΩresistor,and the bridge asymmetry is also evaluated.It is found the asymmetry is in the level of 10-6 for the resistors from 10 kΩto 100 MΩand in the level of 10-5 for 1 kΩresistors.The introduced bridges operations are controlled by LabVIEW programs designed specially for this purpose,and the expanded uncertainty is also evaluated for all measurement results.
文摘A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measurements through ACDC transfer standards for the first time at the National Institute for standards(N IS)in Egypt.The implemented circuit of theautomatic AC-DC switch and its protection are presented in details.An AC voltage source is calibrated against DC voltagesource by using the demonstrated automatic switch as an application The calibrated voltage ranges are2V,6V,20V and60V as examples.The uncertainty budget is also evaluated for the calibrated values.
文摘Current dependence and stability of the measured resistance value are very important for the accurate measurement of DC standard resistor. In this paper, the volt-ampere (V-I) measurement method has been applied to study the current depend-ence of four different types of standard resistors. Diverse values are obtained through the investigation of their stability at dif-ferent currents. Therefore, the current dependence coefficient (CDC) can be determined for each one of the studied resistors. Research shows CDC depends on the applied current value, the measurement time and the resistor type, as clearly demonstra-ted in this research.