Orthotopic liver transplantation(OLT)represents a major treatment for end-stage chronic liver disease,as well as selected cases of hepatocellular carcinoma and acute liver failure.The ever-increasing development of im...Orthotopic liver transplantation(OLT)represents a major treatment for end-stage chronic liver disease,as well as selected cases of hepatocellular carcinoma and acute liver failure.The ever-increasing development of imaging modalities significantly contributed,over the last decades,to the management of recipients both in the pre-operative and post-operative period,thus impacting on graft and patients survival.When properly used,imaging modalities such as ultrasound,multidetector computed tomography,magnetic resonance imaging(MRI)and procedures of direct cholangiography are capable to provide rapid and reliable recognition and treatment of vascular and biliary complications occurring after OLT.Less defined is the role for imaging in assessing primary graft dysfunction(including rejection)or chronic allograft disease after OLT,e.g.,hepatitis C virus(HCV)recurrence.This paper:(1)describes specific characteristic of the above imaging modalities and the rationale for their use in clinical practice;(2)illustrates main imaging findings related to post-OLTcomplications in adult patients;and(3)reviews future perspectives emerging in the surveillance of recipients with HCV recurrence,with special emphasis on MRI.展开更多
Despite advances in patient and graft management,biliary complications(BC)still represent a challenge both in the early and delayed period after orthotopic liver transplantation(OLT).Because of unspecific clinical pre...Despite advances in patient and graft management,biliary complications(BC)still represent a challenge both in the early and delayed period after orthotopic liver transplantation(OLT).Because of unspecific clinical presentation,imaging is often mandatory in order to diagnose BC.Among imaging modalities,magnetic resonance cholangiography(MRC)has gained widespread acceptance as a tool to represent the reconstructed biliary tree noninvasively,using both the conventional technique(based on heavily T2-weighted sequences)and contrast-enhanced MRC(based on the acquisition of T1-weighted sequences after the administration of hepatobiliary contrast agents).On this basis,MRC is generally indicated to:(1)avoid unnecessary procedures of direct cholangiography in patients with a negative examination and/or identify alternative complications;and(2)provide a road map for interventional procedures or surgery.As illustrated in the review,MRC is accurate in the diagnosis of different types of biliarycomplications,including anastomotic strictures,nonanastomotic strictures,leakage and stones.展开更多
AIM To investigate the role of contrast enhanced ultrasound(CEUS) in evaluating patients with renal function impairment(RFI) showing:(1) acute renal failure(ARF) of suspicious vascular origin; or(2) suspicious renal l...AIM To investigate the role of contrast enhanced ultrasound(CEUS) in evaluating patients with renal function impairment(RFI) showing:(1) acute renal failure(ARF) of suspicious vascular origin; or(2) suspicious renal lesions.METHODS We retrospectively evaluated patients addressed to CEUS over an eight years period to rule-out vascular causes of ARF(first group of 50 subjects) or assess previously found suspicious renal lesions(second group of 41 subjects with acute or chronic RFI). After preliminary grey-scale and color Doppler investigation, each kidney was investigated individually with CEUS, using 1.2-2.4 m L of a sulfur hexafluoride-filled microbubble contrast agent. Image analysis was performed in consensus by two readers who reviewed digital clips of CEUS. We calculated the detection rate of vascular abnormalities in the first group and performed descriptive statistics of imaging findings for the second group.RESULTS In the first group, CEUS detected renal infarction orcortical ischemia in 18/50 patients(36%; 95%CI: 23.3-50.9) and 1/50 patients(2%; 95%CI: 0.1-12), respectively. The detection rate of infarction was significantly higher(P = 0.0002; Mc Nemar test) compared to color Doppler ultrasonography(10%). No vascular causes of ARF were identified in the remaining 31/50 patients(62%). In the second group, CEUS detected 41 lesions on 39 patients, allowing differentiation between solid lesions(21/41; 51.2%) vs complex cysts(20/41; 48.8%), and properly addressing 15/39 patients to intervention when feasible based on clinical conditions(surgery and cryoablation in 13 and 2 cases, respectively). Cysts were categorized Bosniak Ⅱ, ⅡF, Ⅲ and Ⅳ in 8, 5, 4 and 3 cases, respectively. In the remaining two patients, CEUS found 1 pseudolesion and 1 subcapsular hematoma.CONCLUSION CEUS showed high detection rate of renal perfusion abnormalities in patients with ARF, influencing the management of patients with acute or chronic RFI and renal masses throughout their proper characterization.展开更多
Kidney transplantation(KT)is an effective treatment for end-stage renal disease.Despite their rate has reduced over time,post-transplant complications still represent a major clinical problem because of the associated...Kidney transplantation(KT)is an effective treatment for end-stage renal disease.Despite their rate has reduced over time,post-transplant complications still represent a major clinical problem because of the associated risk of graft failure and loss.Thus,post-KT complications should be diagnosed and treated promptly.Imaging plays a pivotal role in this setting.Grayscale ultrasound(US)with color Doppler analysis is the first-line imaging modality for assessing complications,although many findings lack specificity.When performed by experienced operators,contrast-enhanced US(CEUS)has been advocated as a safe and fast tool to improve the accuracy of US.Also,when performing CEUS there is potentially no need for further imaging,such as contrast-enhanced computed tomography or magnetic resonance imaging,which are often contraindicated in recipients with impaired renal function.This technique is also portable to patients’bedside,thus having the potential of maximizing the cost-effectiveness of the whole diagnostic process.Finally,the use of blood-pool contrast agents allows translating information on graft microvasculature into time-intensity curves,and in turn quantitative perfusion indexes.Quantitative analysis is under evaluation as a tool to diagnose rejection or other causes of graft dysfunction.In this paper,we review and illustrate the indications to CEUS in the post-KT setting,as well as the main CEUS findings that can help establishing the diagnosis and planning the most adequate treatment.展开更多
AIM To compare high-resolution computed tomography(HRCT) findings between humoral primary immunodeficiencies(hPIDs) subtypes; to correlate these findings to pulmonary function tests(PFTs).METHODS We retrospectively id...AIM To compare high-resolution computed tomography(HRCT) findings between humoral primary immunodeficiencies(hPIDs) subtypes; to correlate these findings to pulmonary function tests(PFTs).METHODS We retrospectively identified 52 consecutive adult patients with hPIDs who underwent 64-row HRCT and PFTs at the time of diagnosis. On a per-patient basis, an experienced radiologist recorded airway abnormalities(bronchiectasis,airway wall thickening, mucus plugging, tree-in-bud, and air-trapping) and parenchymal-interstitial abnormalities(consolidations, ground-glass opacities,linear and/or irregular opacities, nodules, and bullae/cysts) found on HRCT.The chi-square test was performed to compare the prevalence of each abnormality among patients with different subtypes of hPIDs. Overall logistic regression analysis was performed to assess whether HRCT findings predicted obstructive and/or restrictive PFTs results(absent-to-mild vs moderate-tosevere).RESULTS Thirty-eight of the 52 patients with hPIDs showed common variable immunodeficiency disorders(CVID), while the remaining 14 had CVID-like conditions(i.e., 11 had isolated IgG subclass deficiencies and 3 had selective IgA deficiencies). The prevalence of most HRCT abnormalities was not significantly different between CVID and CVID-like patients(P > 0.05), except for linear and/or irregular opacities(prevalence of 31.6% in the CVID group and 0 in the CVID-like group; P = 0.0427). Airway wall thickening was the most frequent HRCT abnormality found in both CVID and CVID-like patients(71% of cases in both groups). The presence of tree-in-bud abnormalities was an independent predictor of moderate-to-severe obstructive defects at PFTs(Odds Ratio, OR, of 18.75, P < 0.05), while the presence of linear and/or irregular opacities was an independent predictor of restrictive defects at PFTs(OR = 13.00; P < 0.05).CONCLUSION CVID and CVID-like patients showed similar HRCT findings. Tree-in-bud and linear and/or irregular opacities predicted higher risks of, respectively,obstructive and restrictive defects at PFTs.展开更多
Associating liver partition and portal vein ligation for staged hepatectomy(ALPPS) is a recently introduced technique aimed to perform two-stage hepatectomy in patients with a variety of primary or secondary neoplasti...Associating liver partition and portal vein ligation for staged hepatectomy(ALPPS) is a recently introduced technique aimed to perform two-stage hepatectomy in patients with a variety of primary or secondary neoplastic lesions. ALPSS is based on a preliminary liver resection associated with ligation of the portal branch directed to the diseased hemiliver(DH), followed by hepatectomy after an interval of time in which the future liver remnant(FLR) hypertrophied adequately(partly because of preserved arterialization of the DH). Multidetector computed tomography(MDCT) and magnetic resonance imaging(MRI) play a pivotal role in patients' selection and FLR assessment before and after the procedure, as well as in monitoring early and late complications, as we aim to review in this paper. Moreover, we illustrate main abdominal MDCT and MRI findings related to ALPPS.展开更多
AIM To investigate the type and timing of evolution of incidentally found branch-duct intraductal papillary mucinous neoplasms(bd-IPMN) of the pancreas addressed to magnetic resonance imaging cholangiopancreatography(...AIM To investigate the type and timing of evolution of incidentally found branch-duct intraductal papillary mucinous neoplasms(bd-IPMN) of the pancreas addressed to magnetic resonance imaging cholangiopancreatography(MRCP) follow-up.METHODS We retrospectively evaluated 72 patients who underwent, over the period 2006-2016, a total of 318 MRCPs(mean 4.4) to follow-up incidental, presumed bdIPMN without signs of malignancy, found or confirmedat a baseline MRCP examination. Median follow-up time was 48.5 mo(range 13-95 mo). MRCPs were acquired on 1.5T and/or 3.0T systems using 2D and/or 3D technique. Image analysis assessed the rates of occurrence over the follow-up of the following outcomes:(1) imaging evolution, defined as any change in cysts number and/or size and/or appearance; and(2) alert findings, defined as worrisome features and/or high risk stigmata(e.g., thick septa, parietal thickening, mural nodules and involvement of the main pancreatic duct). Time to outcomes was described with the Kaplan-Meir approach. Cox regression model was used to investigate clinical or initial MRCP findings predicting cysts changes.RESULTS We found a total of 343 cysts(per-patient mean 5.1) with average size of 8.5 mm(range 5-25 mm). Imaging evolution was observed in 32/72 patients(44.4%; 95%CI: 32-9-56.6), involving 47/343 cysts(13.7%). There was a main trend towards small(< 10 mm) increase and/or decrease of cysts size at a median time of 22.5 mo. Alert findings developed in 6/72 patients(8.3%; 95%CI: 3.4-17.9) over a wide interval of time(13-63 mo). No malignancy was found on endoscopic ultrasound with fine-needle aspiration(5/6 cases) or surgery(1/6 cases). No clinical or initial MRCP features were significantly associated with changes in bd-IPMN appearance(P > 0.01).CONCLUSION Changes in MRCP appearance of incidental bd-IPNM were frequent over the follow-up(44.4%), with relatively rare(8.3%) occurrence of non-malignant alert findings that prompted further diagnostic steps. Changes occurred at a wide interval of time and were unpredictable, suggesting that imaging followup should be not discontinued, though MRCPs might be considerably delayed without a significant risk of missing malignancy.展开更多
An ever-increasing number of 3.0 Tesla(T) magnets are installed worldwide. Moving from the standard of 1.5 T to higher field strength implies a number of potential advantage and drawbacks, requiring careful optimizati...An ever-increasing number of 3.0 Tesla(T) magnets are installed worldwide. Moving from the standard of 1.5 T to higher field strength implies a number of potential advantage and drawbacks, requiring careful optimization of imaging protocols or implementation of novel hardware components. Clinical practice and literature review suggest that state-of-the-art 3.0 T is equivalent to 1.5 T in the assessment of focal liver lesions and diffuse liver disease. Therefore, further technical improvements are needed in order to fully exploit the potential of higher field strength.展开更多
文摘Orthotopic liver transplantation(OLT)represents a major treatment for end-stage chronic liver disease,as well as selected cases of hepatocellular carcinoma and acute liver failure.The ever-increasing development of imaging modalities significantly contributed,over the last decades,to the management of recipients both in the pre-operative and post-operative period,thus impacting on graft and patients survival.When properly used,imaging modalities such as ultrasound,multidetector computed tomography,magnetic resonance imaging(MRI)and procedures of direct cholangiography are capable to provide rapid and reliable recognition and treatment of vascular and biliary complications occurring after OLT.Less defined is the role for imaging in assessing primary graft dysfunction(including rejection)or chronic allograft disease after OLT,e.g.,hepatitis C virus(HCV)recurrence.This paper:(1)describes specific characteristic of the above imaging modalities and the rationale for their use in clinical practice;(2)illustrates main imaging findings related to post-OLTcomplications in adult patients;and(3)reviews future perspectives emerging in the surveillance of recipients with HCV recurrence,with special emphasis on MRI.
文摘Despite advances in patient and graft management,biliary complications(BC)still represent a challenge both in the early and delayed period after orthotopic liver transplantation(OLT).Because of unspecific clinical presentation,imaging is often mandatory in order to diagnose BC.Among imaging modalities,magnetic resonance cholangiography(MRC)has gained widespread acceptance as a tool to represent the reconstructed biliary tree noninvasively,using both the conventional technique(based on heavily T2-weighted sequences)and contrast-enhanced MRC(based on the acquisition of T1-weighted sequences after the administration of hepatobiliary contrast agents).On this basis,MRC is generally indicated to:(1)avoid unnecessary procedures of direct cholangiography in patients with a negative examination and/or identify alternative complications;and(2)provide a road map for interventional procedures or surgery.As illustrated in the review,MRC is accurate in the diagnosis of different types of biliarycomplications,including anastomotic strictures,nonanastomotic strictures,leakage and stones.
文摘AIM To investigate the role of contrast enhanced ultrasound(CEUS) in evaluating patients with renal function impairment(RFI) showing:(1) acute renal failure(ARF) of suspicious vascular origin; or(2) suspicious renal lesions.METHODS We retrospectively evaluated patients addressed to CEUS over an eight years period to rule-out vascular causes of ARF(first group of 50 subjects) or assess previously found suspicious renal lesions(second group of 41 subjects with acute or chronic RFI). After preliminary grey-scale and color Doppler investigation, each kidney was investigated individually with CEUS, using 1.2-2.4 m L of a sulfur hexafluoride-filled microbubble contrast agent. Image analysis was performed in consensus by two readers who reviewed digital clips of CEUS. We calculated the detection rate of vascular abnormalities in the first group and performed descriptive statistics of imaging findings for the second group.RESULTS In the first group, CEUS detected renal infarction orcortical ischemia in 18/50 patients(36%; 95%CI: 23.3-50.9) and 1/50 patients(2%; 95%CI: 0.1-12), respectively. The detection rate of infarction was significantly higher(P = 0.0002; Mc Nemar test) compared to color Doppler ultrasonography(10%). No vascular causes of ARF were identified in the remaining 31/50 patients(62%). In the second group, CEUS detected 41 lesions on 39 patients, allowing differentiation between solid lesions(21/41; 51.2%) vs complex cysts(20/41; 48.8%), and properly addressing 15/39 patients to intervention when feasible based on clinical conditions(surgery and cryoablation in 13 and 2 cases, respectively). Cysts were categorized Bosniak Ⅱ, ⅡF, Ⅲ and Ⅳ in 8, 5, 4 and 3 cases, respectively. In the remaining two patients, CEUS found 1 pseudolesion and 1 subcapsular hematoma.CONCLUSION CEUS showed high detection rate of renal perfusion abnormalities in patients with ARF, influencing the management of patients with acute or chronic RFI and renal masses throughout their proper characterization.
基金The authors thank Viviana Moroso(MSc,PhD)of MV Medical Writing(Luleå,Sweden)for copyediting the manuscript,and Dr.Clara Zichichi(Institute of Radiology,University of Udine)for having drawn Figure 1C.
文摘Kidney transplantation(KT)is an effective treatment for end-stage renal disease.Despite their rate has reduced over time,post-transplant complications still represent a major clinical problem because of the associated risk of graft failure and loss.Thus,post-KT complications should be diagnosed and treated promptly.Imaging plays a pivotal role in this setting.Grayscale ultrasound(US)with color Doppler analysis is the first-line imaging modality for assessing complications,although many findings lack specificity.When performed by experienced operators,contrast-enhanced US(CEUS)has been advocated as a safe and fast tool to improve the accuracy of US.Also,when performing CEUS there is potentially no need for further imaging,such as contrast-enhanced computed tomography or magnetic resonance imaging,which are often contraindicated in recipients with impaired renal function.This technique is also portable to patients’bedside,thus having the potential of maximizing the cost-effectiveness of the whole diagnostic process.Finally,the use of blood-pool contrast agents allows translating information on graft microvasculature into time-intensity curves,and in turn quantitative perfusion indexes.Quantitative analysis is under evaluation as a tool to diagnose rejection or other causes of graft dysfunction.In this paper,we review and illustrate the indications to CEUS in the post-KT setting,as well as the main CEUS findings that can help establishing the diagnosis and planning the most adequate treatment.
基金funded by Department of Medicine, University of Udine (Udine, Italy) in accordance with Good Publication Practice (GPP3) guidelines (http://www.ismpp.org/gpp3)
文摘AIM To compare high-resolution computed tomography(HRCT) findings between humoral primary immunodeficiencies(hPIDs) subtypes; to correlate these findings to pulmonary function tests(PFTs).METHODS We retrospectively identified 52 consecutive adult patients with hPIDs who underwent 64-row HRCT and PFTs at the time of diagnosis. On a per-patient basis, an experienced radiologist recorded airway abnormalities(bronchiectasis,airway wall thickening, mucus plugging, tree-in-bud, and air-trapping) and parenchymal-interstitial abnormalities(consolidations, ground-glass opacities,linear and/or irregular opacities, nodules, and bullae/cysts) found on HRCT.The chi-square test was performed to compare the prevalence of each abnormality among patients with different subtypes of hPIDs. Overall logistic regression analysis was performed to assess whether HRCT findings predicted obstructive and/or restrictive PFTs results(absent-to-mild vs moderate-tosevere).RESULTS Thirty-eight of the 52 patients with hPIDs showed common variable immunodeficiency disorders(CVID), while the remaining 14 had CVID-like conditions(i.e., 11 had isolated IgG subclass deficiencies and 3 had selective IgA deficiencies). The prevalence of most HRCT abnormalities was not significantly different between CVID and CVID-like patients(P > 0.05), except for linear and/or irregular opacities(prevalence of 31.6% in the CVID group and 0 in the CVID-like group; P = 0.0427). Airway wall thickening was the most frequent HRCT abnormality found in both CVID and CVID-like patients(71% of cases in both groups). The presence of tree-in-bud abnormalities was an independent predictor of moderate-to-severe obstructive defects at PFTs(Odds Ratio, OR, of 18.75, P < 0.05), while the presence of linear and/or irregular opacities was an independent predictor of restrictive defects at PFTs(OR = 13.00; P < 0.05).CONCLUSION CVID and CVID-like patients showed similar HRCT findings. Tree-in-bud and linear and/or irregular opacities predicted higher risks of, respectively,obstructive and restrictive defects at PFTs.
文摘Associating liver partition and portal vein ligation for staged hepatectomy(ALPPS) is a recently introduced technique aimed to perform two-stage hepatectomy in patients with a variety of primary or secondary neoplastic lesions. ALPSS is based on a preliminary liver resection associated with ligation of the portal branch directed to the diseased hemiliver(DH), followed by hepatectomy after an interval of time in which the future liver remnant(FLR) hypertrophied adequately(partly because of preserved arterialization of the DH). Multidetector computed tomography(MDCT) and magnetic resonance imaging(MRI) play a pivotal role in patients' selection and FLR assessment before and after the procedure, as well as in monitoring early and late complications, as we aim to review in this paper. Moreover, we illustrate main abdominal MDCT and MRI findings related to ALPPS.
文摘AIM To investigate the type and timing of evolution of incidentally found branch-duct intraductal papillary mucinous neoplasms(bd-IPMN) of the pancreas addressed to magnetic resonance imaging cholangiopancreatography(MRCP) follow-up.METHODS We retrospectively evaluated 72 patients who underwent, over the period 2006-2016, a total of 318 MRCPs(mean 4.4) to follow-up incidental, presumed bdIPMN without signs of malignancy, found or confirmedat a baseline MRCP examination. Median follow-up time was 48.5 mo(range 13-95 mo). MRCPs were acquired on 1.5T and/or 3.0T systems using 2D and/or 3D technique. Image analysis assessed the rates of occurrence over the follow-up of the following outcomes:(1) imaging evolution, defined as any change in cysts number and/or size and/or appearance; and(2) alert findings, defined as worrisome features and/or high risk stigmata(e.g., thick septa, parietal thickening, mural nodules and involvement of the main pancreatic duct). Time to outcomes was described with the Kaplan-Meir approach. Cox regression model was used to investigate clinical or initial MRCP findings predicting cysts changes.RESULTS We found a total of 343 cysts(per-patient mean 5.1) with average size of 8.5 mm(range 5-25 mm). Imaging evolution was observed in 32/72 patients(44.4%; 95%CI: 32-9-56.6), involving 47/343 cysts(13.7%). There was a main trend towards small(< 10 mm) increase and/or decrease of cysts size at a median time of 22.5 mo. Alert findings developed in 6/72 patients(8.3%; 95%CI: 3.4-17.9) over a wide interval of time(13-63 mo). No malignancy was found on endoscopic ultrasound with fine-needle aspiration(5/6 cases) or surgery(1/6 cases). No clinical or initial MRCP features were significantly associated with changes in bd-IPMN appearance(P > 0.01).CONCLUSION Changes in MRCP appearance of incidental bd-IPNM were frequent over the follow-up(44.4%), with relatively rare(8.3%) occurrence of non-malignant alert findings that prompted further diagnostic steps. Changes occurred at a wide interval of time and were unpredictable, suggesting that imaging followup should be not discontinued, though MRCPs might be considerably delayed without a significant risk of missing malignancy.
文摘An ever-increasing number of 3.0 Tesla(T) magnets are installed worldwide. Moving from the standard of 1.5 T to higher field strength implies a number of potential advantage and drawbacks, requiring careful optimization of imaging protocols or implementation of novel hardware components. Clinical practice and literature review suggest that state-of-the-art 3.0 T is equivalent to 1.5 T in the assessment of focal liver lesions and diffuse liver disease. Therefore, further technical improvements are needed in order to fully exploit the potential of higher field strength.