Implementing a signal-switching mechanism for the selective use of integrated sensors and actuators plays a crucial role in streamlining the functionality of miniaturized devices.Here,a liquid metal droplet(LMD)-based...Implementing a signal-switching mechanism for the selective use of integrated sensors and actuators plays a crucial role in streamlining the functionality of miniaturized devices.Here,a liquid metal droplet(LMD)-based signal-switching mechanism is introduced to achieve such functionality.Pressure modulation with a 100-μm spatial resolution enabled precise control of the position of the LMDs within a channel.After integrating the channel with asymmetrically structured electrodes,the effect of the shuttle-like movement of LMD on the temporal changes in the overall capacitance was investigated.Consequently,analysis of the capacitive peaks revealed the directional movement of the LMDs,enabling estimation of the position of the LMDs without direct observation.In addition,we achieved successful signal extraction from the capacitive sensor that was linked to the activated electrodes,thereby enabling selective data retrieval.The proposed signal-switching mechanism method achieved a detection accuracy of~0.1 pF.The sensor’s ability to simultaneously detect the LMD position and generate a signal underscores its significant potential for multiplexing in multisensing systems,particularly in concealed environments,such as in vivo settings.展开更多
基金supported by the Ritsumeikan Advanced Research Academy and the Ritsumeikan Global Innovation Research Organization.
文摘Implementing a signal-switching mechanism for the selective use of integrated sensors and actuators plays a crucial role in streamlining the functionality of miniaturized devices.Here,a liquid metal droplet(LMD)-based signal-switching mechanism is introduced to achieve such functionality.Pressure modulation with a 100-μm spatial resolution enabled precise control of the position of the LMDs within a channel.After integrating the channel with asymmetrically structured electrodes,the effect of the shuttle-like movement of LMD on the temporal changes in the overall capacitance was investigated.Consequently,analysis of the capacitive peaks revealed the directional movement of the LMDs,enabling estimation of the position of the LMDs without direct observation.In addition,we achieved successful signal extraction from the capacitive sensor that was linked to the activated electrodes,thereby enabling selective data retrieval.The proposed signal-switching mechanism method achieved a detection accuracy of~0.1 pF.The sensor’s ability to simultaneously detect the LMD position and generate a signal underscores its significant potential for multiplexing in multisensing systems,particularly in concealed environments,such as in vivo settings.