Fluorescein-rhodamine 6G(Flu-Rh) was synthesized and used as the fluorescence probe for pH measurement based on fluorescence resonance energy transfer(FRET). In the probe, fluorescein fluorophore and pH-sensitive ...Fluorescein-rhodamine 6G(Flu-Rh) was synthesized and used as the fluorescence probe for pH measurement based on fluorescence resonance energy transfer(FRET). In the probe, fluorescein fluorophore and pH-sensitive rhodamine 6G hydrazide were used as FRET donor and acceptor, respectively. The values of acidity constant(pKa) and fluorescence quantum yield(Ф) of Flu-Rh were 3.71 and 0.72, respectively. The fluorescence efficiency of Flu-Rh remains almost constant when the pH value of the sample solution changed 10 times in a range of 4.78-7.03 continuously. The present probe is simple and easy-to-use for the pH measurement in acidic media.展开更多
Facial mask is a kind of skin care cosmetics, in which fluorescent whitening agents(FWAs) were added to make face skin look whiter and brighter. In this work, pig skin was used instead of human skin to test the meth...Facial mask is a kind of skin care cosmetics, in which fluorescent whitening agents(FWAs) were added to make face skin look whiter and brighter. In this work, pig skin was used instead of human skin to test the methods. Three methods, including pig skin migration fluorescent spectrophotometry(FS), fiber paper migration FS, and fiber paper migration visual colourimetry(VC), were developed for determining the migration amount of FWAs from facial mask to pig skin. In the methods, a self-assembly light source and fluorescence collecting unit was used. The unit can be easily moved and the measurement was very convenient. Some experimental conditions were optimized. The fiber paper migration VC can give semi-quantitative results and was the simplest one in the three methods because collec- tion, separation and detection of the fluorescence were not needed. Both the pig skin migration FS and fiber paper migration FS can give quantitative results and compared with fiber paper migration FS, the pig skin migration FS could give more practical results by simulating the real way of using facial mask. The limits of detection for disodium 4,4'-bis[(4-anilino-6-hydroxyethylamion-1,3,5-triazin-2-yl)amion]stilbene-2,2'-disulphonate(VBL) obtained by pig skin migration FS and fiber paper migration FS were 0.03 and 0.05 mg/m2, respectively. 96 kinds of samples were analyzed and the migration amounts of FWAs in 21 kinds of samples were detectable. Correlations between migration amounts obtained by the three methods were very good. Experimental results indicate that the present methods can be applied to the determination of migration amount of FWAs in facial masks.展开更多
A kind of novel environmental-friendly composite absorbent material was designed and prepared in this paper.Nanoscale metal-organic frameworks(MOFs)were embedded in the skeleton of cotton micro fibrillated cellulose.B...A kind of novel environmental-friendly composite absorbent material was designed and prepared in this paper.Nanoscale metal-organic frameworks(MOFs)were embedded in the skeleton of cotton micro fibrillated cellulose.By scanning electron microscope(SEM),we observed that a large number of MOFs were attached to the cellulose skeleton.In addition,under the condition of 1800 r/min vortex,the structure of the composite material was stable and was not easily damaged by external forces.The water contact angle test showed that the composite material had excellent hydrophilicity and could be used for the adsorption of pollutants.Then,the material was characterized by energy dispersive X-ray spectroscopy(EDX),X-ray diffraction(XRD),Fourier transform infrared spectroscopy(FTIR)and BET adsorption.Through verification,the material had very stable reusability(n=10).The composite material was applied to the solid phase extraction of water samples,such as rain water,toning water and fruit juice,and was quantitatively analyzed by high performance liquid chromatography(HPLC)-UV.This method was then applied to the extraction of four parabens(methyl-,ethyl-,propyl-,and butylparaben)from real samples,yielding limits of detection(LODs)of 0.29-0.58 ng/mL.The linear range was 2-500 ng/mL.The inter-day and intra-day recoveries were 90.7%-106.0%and 87.1%-109.3%,respectively(relative standard deviation<10.8%).展开更多
基金Supported by the National Natural Science Foundation of China(Nos.21405057, 21207047) and the Science and Technology Developing Foundation of Jilin Province, China(No.20125006).
文摘Fluorescein-rhodamine 6G(Flu-Rh) was synthesized and used as the fluorescence probe for pH measurement based on fluorescence resonance energy transfer(FRET). In the probe, fluorescein fluorophore and pH-sensitive rhodamine 6G hydrazide were used as FRET donor and acceptor, respectively. The values of acidity constant(pKa) and fluorescence quantum yield(Ф) of Flu-Rh were 3.71 and 0.72, respectively. The fluorescence efficiency of Flu-Rh remains almost constant when the pH value of the sample solution changed 10 times in a range of 4.78-7.03 continuously. The present probe is simple and easy-to-use for the pH measurement in acidic media.
文摘Facial mask is a kind of skin care cosmetics, in which fluorescent whitening agents(FWAs) were added to make face skin look whiter and brighter. In this work, pig skin was used instead of human skin to test the methods. Three methods, including pig skin migration fluorescent spectrophotometry(FS), fiber paper migration FS, and fiber paper migration visual colourimetry(VC), were developed for determining the migration amount of FWAs from facial mask to pig skin. In the methods, a self-assembly light source and fluorescence collecting unit was used. The unit can be easily moved and the measurement was very convenient. Some experimental conditions were optimized. The fiber paper migration VC can give semi-quantitative results and was the simplest one in the three methods because collec- tion, separation and detection of the fluorescence were not needed. Both the pig skin migration FS and fiber paper migration FS can give quantitative results and compared with fiber paper migration FS, the pig skin migration FS could give more practical results by simulating the real way of using facial mask. The limits of detection for disodium 4,4'-bis[(4-anilino-6-hydroxyethylamion-1,3,5-triazin-2-yl)amion]stilbene-2,2'-disulphonate(VBL) obtained by pig skin migration FS and fiber paper migration FS were 0.03 and 0.05 mg/m2, respectively. 96 kinds of samples were analyzed and the migration amounts of FWAs in 21 kinds of samples were detectable. Correlations between migration amounts obtained by the three methods were very good. Experimental results indicate that the present methods can be applied to the determination of migration amount of FWAs in facial masks.
基金This work was supported by the National Natural Science Foundation of China(Nos.22074052 and 22004046)the Science and Technology Developing Foundation of Jilin Province of China(No.20200404173YY).
文摘A kind of novel environmental-friendly composite absorbent material was designed and prepared in this paper.Nanoscale metal-organic frameworks(MOFs)were embedded in the skeleton of cotton micro fibrillated cellulose.By scanning electron microscope(SEM),we observed that a large number of MOFs were attached to the cellulose skeleton.In addition,under the condition of 1800 r/min vortex,the structure of the composite material was stable and was not easily damaged by external forces.The water contact angle test showed that the composite material had excellent hydrophilicity and could be used for the adsorption of pollutants.Then,the material was characterized by energy dispersive X-ray spectroscopy(EDX),X-ray diffraction(XRD),Fourier transform infrared spectroscopy(FTIR)and BET adsorption.Through verification,the material had very stable reusability(n=10).The composite material was applied to the solid phase extraction of water samples,such as rain water,toning water and fruit juice,and was quantitatively analyzed by high performance liquid chromatography(HPLC)-UV.This method was then applied to the extraction of four parabens(methyl-,ethyl-,propyl-,and butylparaben)from real samples,yielding limits of detection(LODs)of 0.29-0.58 ng/mL.The linear range was 2-500 ng/mL.The inter-day and intra-day recoveries were 90.7%-106.0%and 87.1%-109.3%,respectively(relative standard deviation<10.8%).