期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
The Numerical Comparison of Heat Transfer in a Coated and Fixed Bed of an Adsorption Chiller 被引量:2
1
作者 GRABOWSKA karolina SOSNOWSKI Marcin +4 位作者 KRZYWANSKI Jaroslaw sztekler karol KALAWA Wojciech ZYLKA Anna NOWAK Wojciech 《Journal of Thermal Science》 SCIE EI CAS CSCD 2018年第5期421-426,共6页
Ecological adsorption technology is becoming a focus of attention by industry due to the utilization of low grade thermal energy sources for cooling production. It can be a promising part of sustainable development co... Ecological adsorption technology is becoming a focus of attention by industry due to the utilization of low grade thermal energy sources for cooling production. It can be a promising part of sustainable development concept of the global economy. Therefore, research aiming at improving their performance i.e. Coefficient of Performance(COP) by optimizing the construction of sorption beds with a built in heat exchanger system is crucial. The heat transfer characteristics between the bed of porous media(sorbent) and surface of the heat exchanger system determine the heating power of an adsorption chiller. The HP increase can be obtained by heat transfer intensification due to the increase in the thermal conductivity of the sorbent layer in the vicinity of the heat exchanger's surface. The novel modification of the sorbent layer structure is proposed in the paper in order to improve the heat transfer processes in the heat exchanger boundary layer. The analysis of desorption process conditions in the parametric model of a coated and fixed adsorption bed design is presented in the paper. The computational fluid dynamics(CFD) with conjugate heat transfer analysis is used to determine the crucial input parameters(temperature distribution in the sorbent bed) for further analytical calculations. The commercial code Ansys Fluent was used to perform numerical simulations. The developed computational model consisted of three subdomains representing heating water, heat exchanger material(copper) and sorbent(silica gel). The comparison of a novel coated design and a conventional fixed bed is discussed in the paper. The numerical analysis is based on experimental thermal conductivity measurements of the sorbent layer in different configurations, which were performed using Laser Flash Method. 展开更多
关键词 adsorption chiller computational fluid dynamics low grade thermal energy sources coated adsorption bed silica gel thermal conductivity
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部