期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Measurement of Gamma-Rays Induced Luminescence Generated in a Sapphire Based Fiber-Optic Radiation Sensor
1
作者 Young Beom Song Kyoung Won Jang +5 位作者 Hye Jin Kim Dong Eun Lee Mingeon Kim sang hun shin Wook Jae Yoo Bongsoo Lee 《Journal of Applied Mathematics and Physics》 2016年第8期1503-1506,共5页
In this study, we fabricated a sapphire based fiber-optic radiation sensor. To evaluate the fiber- optic radiation sensor, we measured the spectrum and intensity of the luminescence generated from the fiber-optic radi... In this study, we fabricated a sapphire based fiber-optic radiation sensor. To evaluate the fiber- optic radiation sensor, we measured the spectrum and intensity of the luminescence generated from the fiber-optic radiation sensor according to the thickness of the PMMA block by irradiation of gamma rays emitted from a Co-60 source. And the result was compared with the value calculated from the formula of Lambert-Beer. 展开更多
关键词 Fiber-Optic Radiation Sensor Optical Glass SAPPHIRE LUMINESCENCE Gamma Ray Source Spent Fuel
下载PDF
Comparison of Depth Dose Distributions Using Cerenkov Fiber-Optic Dosimeter and Monte Carlo Simulation for HDR Brachytherapy
2
作者 sang hun shin Young Beom Song +4 位作者 Mingeon Kim Hye Jin Kim Wook Jae Yoo Kyoung Won Jang Bongsoo Lee 《Journal of Applied Mathematics and Physics》 2016年第8期1499-1502,共5页
In this study, we fabricated a Cerenkov fiber-optic dosimeter (CFOD) without any scintillator to measure Cerenkov radiation signals owing to gamma-rays. The relative depth dose (RDD) distributions of Ir-192 HDR brachy... In this study, we fabricated a Cerenkov fiber-optic dosimeter (CFOD) without any scintillator to measure Cerenkov radiation signals owing to gamma-rays. The relative depth dose (RDD) distributions of Ir-192 HDR brachytherapy source were obtained by using the CFOD based on a subtraction method and the RDD curve was compared with the simulation result of Monte Carlo N-particle extended transport code (MCNPX). Finally, we demonstrated that the CFOD can be used to measure real-time dose information for HDR brachytherapy. 展开更多
关键词 Cerenkov Fiber-Optic Dosimeter Cerenkov Radiation GAMMA-RAY Relative Depth Dose HDR Brachytherapy
下载PDF
Comparative study of chitosan/fibroin–hydroxyapatite and collagen membranes for guided bone regeneration in rat calvarial defects: micro-computed tomography analysis 被引量:15
3
作者 Jae Min Song sang hun shin +4 位作者 Yong Deok Kim Jae Yeol Lee Young Jae Baek sang Yong Yoon Hong Sung Kim 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第2期87-93,共7页
This study aimed to utilize micro-computed tomography (micro-CT) analysis to compare new bone formation in rat calvarial defects using chitosan/fibroin-hydroxyapatite (CFB-HAP) or collagen (Bio-Gide) membranes. ... This study aimed to utilize micro-computed tomography (micro-CT) analysis to compare new bone formation in rat calvarial defects using chitosan/fibroin-hydroxyapatite (CFB-HAP) or collagen (Bio-Gide) membranes. Fifty-four (54) rats were studied. A circular bony defect (8 mm diameter) was formed in the centre of the calvaria using a trephine bur. The CFB-HAP membrane was prepared by thermally induced phase separation. In the experimental group (n= 18), the CFB-HAP membrane was used to cover the bony defect, and in the control group (n= 18), a resorbable collagen membrane (Bio-Gide) was used. In the negative control group (n= 18), no membrane was used. In each group, six animals were euthanized at 2, 4 and 8 weeks after surgery. The specimens were then analysed using micro-CT. There were significant differences in bone volume (BV) and bone mineral density (BMD) (P〈O.05) between the negative control group and the membrane groups. However, there were no significant differences between the CFB-HAP group and the collagen group. We concluded that the CFB-HAP membrane has significant potential as a guided bone regeneration (GBR) membrane. 展开更多
关键词 chitosan/fibroin-hydroxyapatite collagen membrane guided bone regeneration micro-computed tomography rat calva rial defect
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部