The role of microstructural features on in-vitro degradation and surface film development of a thermomechanically processed Mg-4Zn-0.5Ca-0.8Mn alloy has been investigated employing electrochemical studies,scanning ele...The role of microstructural features on in-vitro degradation and surface film development of a thermomechanically processed Mg-4Zn-0.5Ca-0.8Mn alloy has been investigated employing electrochemical studies,scanning electron microscopy and X-ray photoelectron spectroscopy.The specimen forged at 523 K temperature developed a coarse unimodal microstructure consisting of basal oriented grains,whereas the specimens forged at 623 K and 723 K temperatures exhibited bimodal microstructures containing randomly oriented fine grains and basal oriented coarse grains.The bimodal microstructures exerted higher resistance to corrosion compared to the unimodal microstructure in presence of a protective surface film.The optimum size distribution of fine and coarse grains as well as the prevalence of basal oriented grains led to the lowest anodic current density in the specimen forged at 623 K.The morphology of Ca_(2)Mg_(6)Zn_(3)precipitates governed the cathodic kinetics by controlling the anode to cathode surface area ratio.Despite the specimen forged at 723 K comprised comparatively lower fraction of precipitates than at 623 K,the mesh-like precipitate morphology increased the effective cathodic surface area,leading to enhanced localised corrosion in the former specimen.Optimal microstructural features developed at 623 K forging temperature formed a well-protective surface film with lower Mg(OH)_(2)to MgO ratio,exhibiting distinctly high polarization resistance and superior cytocompatibility in terms of cell-proliferation and cell-differentiation.展开更多
In recent years,iron(Fe)based degradable metal is explored as an alternative to permanent fracture fixation devices.In the present work,copper(Cu)is added in Fe-Mn system to enhance the degradation rate and antimicrob...In recent years,iron(Fe)based degradable metal is explored as an alternative to permanent fracture fixation devices.In the present work,copper(Cu)is added in Fe-Mn system to enhance the degradation rate and antimicrobial properties.Fe-Mn-x Cu(x=0.9,5 and 10 wt.%)alloys are prepared by the meltingcasting-forging route.XRD analysis confirms austenite phase stabilization due to the presence of Mn and Cu.As predicted by Thermo-Calc calculations,Cu rich phase precipitations are noticed along the austenite grain boundaries.Degradation behaviours of Cu added Fe-Mn alloys are investigated through static immersion and electrochemical polarization where enhanced degradation is found for higher Cu added alloys.When challenged against E.Coli bacteria,the Fe-Mn-Cu alloy media extract shows a significant bactericidal effect compare to the base alloy.In vitro cytocompatibility studies,as determined using MG63 and MC3T3-E1 cell lines,indicate increased cell density as a function of time for all the alloys.When implanted in rabbit femur,the newly developed alloy does not show any kind of tissue necrosis around the implants.Better osteogenesis and higher new bone formation are observed with Fe-Mn-10 Cu alloy as evident from micro-computed tomography(μ-CT)and fluorochrome labelling.展开更多
文摘The role of microstructural features on in-vitro degradation and surface film development of a thermomechanically processed Mg-4Zn-0.5Ca-0.8Mn alloy has been investigated employing electrochemical studies,scanning electron microscopy and X-ray photoelectron spectroscopy.The specimen forged at 523 K temperature developed a coarse unimodal microstructure consisting of basal oriented grains,whereas the specimens forged at 623 K and 723 K temperatures exhibited bimodal microstructures containing randomly oriented fine grains and basal oriented coarse grains.The bimodal microstructures exerted higher resistance to corrosion compared to the unimodal microstructure in presence of a protective surface film.The optimum size distribution of fine and coarse grains as well as the prevalence of basal oriented grains led to the lowest anodic current density in the specimen forged at 623 K.The morphology of Ca_(2)Mg_(6)Zn_(3)precipitates governed the cathodic kinetics by controlling the anode to cathode surface area ratio.Despite the specimen forged at 723 K comprised comparatively lower fraction of precipitates than at 623 K,the mesh-like precipitate morphology increased the effective cathodic surface area,leading to enhanced localised corrosion in the former specimen.Optimal microstructural features developed at 623 K forging temperature formed a well-protective surface film with lower Mg(OH)_(2)to MgO ratio,exhibiting distinctly high polarization resistance and superior cytocompatibility in terms of cell-proliferation and cell-differentiation.
基金the financial assistance from Indian Institute of Technology-Kharagpur(IIT-Kharagpur)。
文摘In recent years,iron(Fe)based degradable metal is explored as an alternative to permanent fracture fixation devices.In the present work,copper(Cu)is added in Fe-Mn system to enhance the degradation rate and antimicrobial properties.Fe-Mn-x Cu(x=0.9,5 and 10 wt.%)alloys are prepared by the meltingcasting-forging route.XRD analysis confirms austenite phase stabilization due to the presence of Mn and Cu.As predicted by Thermo-Calc calculations,Cu rich phase precipitations are noticed along the austenite grain boundaries.Degradation behaviours of Cu added Fe-Mn alloys are investigated through static immersion and electrochemical polarization where enhanced degradation is found for higher Cu added alloys.When challenged against E.Coli bacteria,the Fe-Mn-Cu alloy media extract shows a significant bactericidal effect compare to the base alloy.In vitro cytocompatibility studies,as determined using MG63 and MC3T3-E1 cell lines,indicate increased cell density as a function of time for all the alloys.When implanted in rabbit femur,the newly developed alloy does not show any kind of tissue necrosis around the implants.Better osteogenesis and higher new bone formation are observed with Fe-Mn-10 Cu alloy as evident from micro-computed tomography(μ-CT)and fluorochrome labelling.