期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Long Term Follow up of the Solyx Single Incision Sling in the Treatment of Female Stress Urinary Incontinence (SUI) 被引量:3
1
作者 scott serels Michael Douso 《Open Journal of Urology》 2014年第2期13-17,共5页
Objectives: The Solyx System was developed to be easier and safer to use than other slings. It was the objective of this study to retrospectively assess the long-term safety and efficacy of the SolyxTM SIS Sling Syste... Objectives: The Solyx System was developed to be easier and safer to use than other slings. It was the objective of this study to retrospectively assess the long-term safety and efficacy of the SolyxTM SIS Sling System. Methods: After IRB approval and informed consent, chart reviews with follow up phone questionnaires of 69 subjects implanted with the Solyx Sling were collected at 2 sites. All of the patients had SUI and had urethral hypermobility with a q-tip test of >30 degrees. All subjects underwent surgery from 12/2008 to 01/2010 with a mean follow up of 43 months (range 39 -49). Subjects included in this data collection had a mean age of 67 years (range 30 -87). The dominant type of incontinence within the study patients was SUI while 17/69 (25%) of the subjects also had a component of urge incontinence. 38/69 (55%) of study patients had concomitant procedures. Results: Long-term Solyx results showed 64/69 (93%) of patients were subjectively dry by questionnaire and were satisfied with their outcome. 63/69 (91%) would have the procedure again. There were 4 cases of denovo urge incontinence and 2 reports of transient retention. There were no serious adverse events including no bladder, bowel, vessel or nerve perforations and no erosions or extrusions. No pain was reported that was attributed to the implant. Conclusions: Chart review with follow phone questionnaires indicated that the Solyx Sling was a safe, efficacious and less-invasive option for patients requiring SUI surgery and that these results were sustainable for an average of 43 months. 展开更多
关键词 Single INCISION SLING STRESS URINARY INCONTINENCE
下载PDF
Cadaveric Assessment of Synthetic Mid-Urethral Sling Placement
2
作者 scott serels 《Open Journal of Urology》 2011年第2期19-24,共6页
Purpose: To determine if 3 types of mid-urethral synthetic slings are visually the same. Materials and Methods: A retropubic, obturator, and single incision sling was individually placed in three cadavers. Tension was... Purpose: To determine if 3 types of mid-urethral synthetic slings are visually the same. Materials and Methods: A retropubic, obturator, and single incision sling was individually placed in three cadavers. Tension was set using a spacer (obturator and retropubic). Single incision sling (SIS) tension was set by visual inspection. Thirty physicians were asked to determine placement method, tension, and location of the 3 slings. Results: Physicians were composed of 5 urologists, 7 urogynecologist, and 18 general gynecologists, with an average of 53 slings performed per year. Conclusion: This study showed that after placement of a sling it is hard to tell how the sling was placed and that most physicians felt the SIS was tensioned the best and most likely at the mid-urethra. 展开更多
关键词 Stress INCONTINENCE SURGICAL Correction of INCONTINENCE Single INCISION SLINGS
下载PDF
Single incision slings: Past, present, and future
3
作者 scott serels 《World Journal of Obstetrics and Gynecology》 2015年第3期68-71,共4页
Pubovaginal slings have become the gold standard to treat stress urinary incontinence. Traditionally, the sling referred to a suspensory that was placed under the urethra and brought through the retropubic space and a... Pubovaginal slings have become the gold standard to treat stress urinary incontinence. Traditionally, the sling referred to a suspensory that was placed under the urethra and brought through the retropubic space and anchored on either side of the midline. Since this original concept, there have been many materials used for the sling, and there have been many different anchoring approaches. Most agree that one of the best materials is polypropylene mesh. However, the means of anchoring the device and where best to have this anchorage placed is debatable. The options for anchoring simply include using darts vs not to hold the sling in place. The location of this anchorage, on the other hand, is much more controversial. The main locations are retropubic, transobturator, and via a single incision. The obturator and retropubic slings have become the standard of care over time. The single incision sling, on the other hand, is starting to be more acceptable which has resulted in it being used more frequently. The single incision relies on mainly anchoring the sling through the obturator internus muscle with possible inclusion of the obturator membrane. The purpose of this review article is to present the data that exists for the use of the single incision sling. 展开更多
关键词 SLING Stress urinary incontinence Incon-tinence Single incision sling SURGERY
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部