期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Spatial sensitivity to absorption changes for various near-infrared spectroscopy methods:A compendium review
1
作者 Giles Blaney Angelo Sassaroli sergio fantini 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第4期1-115,共115页
This compendium review focuses on the spatial distribution of sensitivity to localized absorption changes in optically diffuse media,particularly for measurements relevant to near-infrared spectroscopy.The three tempo... This compendium review focuses on the spatial distribution of sensitivity to localized absorption changes in optically diffuse media,particularly for measurements relevant to near-infrared spectroscopy.The three temporal domains,continuous wave,frequency domain,and time domain,each obtain different optical data types whose changes may be related to effective homogeneous changes in the absorption coefficient.Sensitivity is the relationship between a localized perturbation and the recovered effective homogeneous absorption change.Therefore,spatial sensitivity maps representing the perturbation location can be generated for the numerous optical data types in the three temporal domains.The review first presents a history of the past 30 years of work investigating this sensitivity in optically diffuse media.These works are experimental and theoretical,presenting one-,two-,and three-dimensional sensitivity maps for different Near-Infrared Spectroscopy methods,domains,and data types.Following this history,we present a compendium of sensitivity maps organized by temporal domain and then data type.This compendium provides a valuable tool to compare the spatial sensitivity of various measurement methods and parameters in one document.Methods for one to generate these maps are provided in Appendix A,including the code.This historical review and comprehensive sensitivity map compendium provides a single source researchers may use to visualize,investigate,compare,and generate sensitivity to localized absorption change maps. 展开更多
关键词 Diffuse optics diffusion theory Monte Carlo spatial sensitivity absorption perturbations near-infrared spectroscopy CONTINUOUS-WAVE FREQUENCY-DOMAIN time-domain
下载PDF
Introduction to Special Issue on Neurophotonics
2
作者 sergio fantini Ling Fu Sabrina Brigadoi 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2023年第6期1-2,共2页
Optoelectronics,genomics,and proteomics have ushered in an era of new approaches and tools for neuroscience research,especially optical neuroimaging."Function follows form",anatomical structure is the basis ... Optoelectronics,genomics,and proteomics have ushered in an era of new approaches and tools for neuroscience research,especially optical neuroimaging."Function follows form",anatomical structure is the basis for understanding brain function and brain diseases.Brain function depends on neuronal networks,so from a systems biology perspective,not only should the neuronal level be studied,but also the neuronal networks and system levels.Optical imaging can now be applied at multiple levels,from the gene to the molecule,from the cell to the tissue,and from the organ to the system,to provide critical information that bridges molecular structure and physiological function. 展开更多
关键词 function. BRIDGES struc
下载PDF
DISCRIMINATION OF MENTAL WORKLOAD LEVELS IN HUMAN SUBJECTS WITH FUNCTIONAL NEAR-INFRARED SPECTROSCOPY 被引量:1
3
作者 ANGELO SASSAROLI FENG ZHENG +4 位作者 LEANNE M.HIRSHFIELD AUDREY GIROUARD ERIN TREACY SOLOVEY ROBERT J.K.JACOB sergio fantini 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2008年第2期227-237,共11页
We have applied functional near-infrared spectroscopy(fNIRS)to the human forehead to distinguish different levels of mental workload on the basis of hemodynamic changes occurring in the prefrontal cortex.We report dat... We have applied functional near-infrared spectroscopy(fNIRS)to the human forehead to distinguish different levels of mental workload on the basis of hemodynamic changes occurring in the prefrontal cortex.We report data on 3 subjects from a protocol involving 3 mental workload levels based on to working memory tasks.To quantify the potential of fNIRS for mental workload discrimination,we have applied a 3-nearest neighbor classification algorithm based on the amplitude of oxyhemoglobin(HbO2)and deoxyhemoglobin(HbR)concentration changes associated with the working memory tasks.We have found classification success rates in the range of 44%-72%,which are significantly higher than the corresponding chance level(for random data)of 19.1%.This work shows the potential of fNIRS for mental workload classification,especially when more parameters(rather than just the amplitude of concentration changes used here)and more sophisticated classification algorithms(rather than the simple 3-nearest neighbor algorithm used here)are considered and optimized for this application. 展开更多
关键词 Diffuse optical imaging near-infrared spectroscopy functional brain imaging working memory mental workload
下载PDF
PHASE DIFFERENCE BETWEEN LOW-FREQUENCY OSCILLATIONS OF CEREBRAL DEOXY-AND OXY-HEMOGLOBIN CONCENTRATIONS DURING A MENTAL TASK
4
作者 ANGELO SASSAROLI FENG ZHENG +2 位作者 MICHELE PIERRO PETER R.BERGETHON sergio fantini 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2011年第2期151-158,共8页
Hemodynamic low-frequency(~0.1 Hz)spontaneous oscillations as detected in the brain by nearinfrared spectroscopy have potential applications in the study of brain activation,cerebral autoregulation,and functional conn... Hemodynamic low-frequency(~0.1 Hz)spontaneous oscillations as detected in the brain by nearinfrared spectroscopy have potential applications in the study of brain activation,cerebral autoregulation,and functional connectivity.In this work,we have investigated the phase lag between oscillations of cerebral deoxy-and oxy-hemoglobin concentrations in the frequency range 0.05-0.10 Hz in a human subject during a mental workload task.We have obtained a measure of such phase lag using two different methods:(1)phase synchronization analysis as used in the theory of chaotic oscillators and(2)a novel cross-correlation phasor approach.The two methods yielded comparable initial results of a larger phase lag between low-frequency oscillations of deoxy-and oxyhemoglobin concentrations during mental workload with respect to a control,rest condition. 展开更多
关键词 Phase lag OXYHEMOGLOBIN DEOXYHEMOGLOBIN phase synchronization cross-correlation phasor LFO
下载PDF
Broadband diffuse optical spectroscopy of two-layered scattering media containing oxyhemoglobin,deoxyhemoglobin,water,and lipids
5
作者 Giles Blaney Martina Bottoni +2 位作者 Angelo Sassaroli Cristianne Fernandez sergio fantini 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2022年第3期92-106,共15页
We investigated the relationship between chromophore concentrations in two-layered scattering media and the apparent chromophore concentrations measured with broadband optical spectroscopy in conjunction with commonly... We investigated the relationship between chromophore concentrations in two-layered scattering media and the apparent chromophore concentrations measured with broadband optical spectroscopy in conjunction with commonly used homogeneous medium inverse models.We used diffusion theory to generate optical data from a two-layered distribution of relevant tissue absorbers,namely,oxyhemoglobin,deoxyhemoglobin,water,and lipids,with a top-layer thickness in the range 1–15 mm.The generated data consisted of broadband continuous-wave(CW)diffuse reflectance in the wavelength range 650–1024 nm,and frequency-domain(FD)diffuse reflectance at 690 and 830 nm;two source-detector distances of 25 and 35mm were used to simulate a dual-slope technique.The data were inverted using diffusion theory for a semi-infinite homogeneous medium to generate reduced scattering coeffcients at 690 and 830nm(from FD data)and effective absorption spectra in the range 650–1024nm(from CW data).The absorption spectra were then converted into effective total concentration and oxygen saturation of hemoglobin,as well as water and lipid concentrations.For absolute values,it was found that the effective hemoglobin parameters are typically representative of the bottom layer,whereas water and lipid represent some average of the respective concentrations in the two layers.For concentration changes,lipid showed a significant cross-talk with other absorber concentrations,thus indicating that lipid dynamics obtained in these conditions may not be reliable.These systematic simulations of broadband spectroscopy of two-layered media provide guidance on how to interpret effective optical properties measured with similar instrumental setups under the assumption of medium homogeneity. 展开更多
关键词 Broadband spectroscopy two-layer medium heterogeneous forward model homo-geneous inverse model partial-volume effect
下载PDF
Transformational change in the field of diffuse optics:From going bananas to going nuts
6
作者 sergio fantini Giles Blaney Angelo Sassaroli 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2020年第1期1-18,共18页
The concept of region of sensitivity is central to the field of diffuse optics and is closely related to the Jacobian matrix used to solve the inverse problem in imaging.It is well known that,in diffuse reflectance,th... The concept of region of sensitivity is central to the field of diffuse optics and is closely related to the Jacobian matrix used to solve the inverse problem in imaging.It is well known that,in diffuse reflectance,the region of sensitivity associated with a given source-detector pair is shaped as a banana,and features maximal sensitivity to the portions of the sample that are closest to the source and the detector.We have recently introduced a dual-slope(DS)method based on a special arrangement of two sources and two detectors,which results in deeper and more localized regions of sensitivity,resembling the shapes of different kinds of nuts.Here,we report the regions of sensitivity associated with a variety of source-detector arrangements for DS measurements of intensity and phase with frequency-domain spectroscopy(modulation frequency:140 MHz)in a medium with absorption and reduced scattering coefficients of 0.1 and 12 cm^(-1),respectively.The main result is that the depth of maximum sensitivity,considering only cases that use source-detector separations of 25 and 35 mm,progressively increases as we consider single-distance intensity(2.0mm),DS intensity(4.6mm),single-distance phase(7.5mm),and DS phase(10.9 mm).These results indicate the importance of DS measurements,and even more so of phase measurements,when it is desirable to selectively probe deeper portions of a sample with diffuse optics.This is certainly the case in non-invasive optical studies of brain,muscle,and breast tissue,which are located underneath the superficial tissue at variable depths. 展开更多
关键词 Near-infrared spectroscopy tissue optics diffuse optical tomography frequency domain dual slopes
下载PDF
Study of capillary transit time distribution in coherent hemodynamics spectroscopy
7
作者 Angelo Sassaroli Jana Kainerstorfer sergio fantini 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2015年第2期78-86,共9页
A recently proposed analytical hemodynamie modell[s.Fantini,Neurolmage 85,202-221(2014)]is able to predict the changes of oxy,deoxy,and total hemoglobin concentrations(model outputs)given arbitrary changes in blood fl... A recently proposed analytical hemodynamie modell[s.Fantini,Neurolmage 85,202-221(2014)]is able to predict the changes of oxy,deoxy,and total hemoglobin concentrations(model outputs)given arbitrary changes in blood flow,blood volume,and rate of oygen consumption(model inputs).One asumption of this model is that the capillary compartment is characterized by a single blood transit time.In this work,we have extended the original model by considering a distribution of capillary transit times and we have compared the outputs of both models(original and extended)for the case of sinusoidal input signals at different frequencies,which realizes the new technique of coherent hemodynamics spectroscopy(CHS).For the calculations with the original model,we have used the mean value of the distribution of capillary transit times con-sidered in the extended model.We have found that,for distributions of capillary transit times having mean values around 1 s and a standard deviation less than about 45%of the mean value,the original and extended models yield the same CHS spectra(i.e.,model outputs versus fre-quency of ocillation)within typical experimental errors.For wider capillary transit time dis-tributions,the two models yield different CHS spectra.By assuming that Poiseuille's law is valid in the capillary compartment,we have related the distribution of capillary transit times to the distributions of capillary lengths and capillary speed of blood flow to calculate the average capillary and venous saturations.We have found that,for standard deviations of the capillanry transit time distrilbution that are less than about 80%of the mean value,the average capillary saturation is always larger than the venous saturation.By contrast,the average capillary satu-ration may be less than the venous saturation for wider distributions of the capillary transit times. 展开更多
关键词 Coherent hemodynamics spectroscopy hermodynamie model near-infrared spectros-copy capillary transit time hemoglobin saturation
下载PDF
NEAR-INFRARED,BROAD-BAND SPECTRAL IMAGING OF THE HUMAN BREAST FOR QUANTITATIVE OXIMETRY:APPLICATIONS TO HEALTHY AND CANCEROUS BREASTS
8
作者 YANG YU ANGELO SASSAROLI +3 位作者 DEBBIE K.CHEN MARC J.HOMER ROGER A.GRAHAM sergio fantini 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2010年第4期267-277,共11页
We have examined ten human subjects with a previously developed instrument for near-infrared diffuse spectral imaging of the female breast.The instrument is based on a tandem,planar scan of two collinear optical fiber... We have examined ten human subjects with a previously developed instrument for near-infrared diffuse spectral imaging of the female breast.The instrument is based on a tandem,planar scan of two collinear optical fibers(one for illumination and one for collection)to image a gently compressed breast in a transmission geometry.The optical data collection features a spatial sampling of 25 points/cm2 over the whole breast,and a spectral sampling of 2 points/nm in the 650-900nm wavelength range.Of the ten human subjects examined,eight are healthy subjects and two are cancer patients with unilateral invasive ductal carcinoma and ductal carcinoma in situ,respectively.For each subject,we generate second-derivative images that identify a network of highly absorbing structures in the breast that we assign to blood vessels.A previously developed paired-wavelength spectral method assigns oxygenation values to the absorbing structures displayed in the second-derivative images.The resulting oxygenation images feature average values over the whole breast that are significantly lower in cancerous breasts(69±14%,n=2)than in healthy breasts(85±7%,n=18)(p<0.01).Furthermore,in the two patients with breast cancer,the average oxygenation values in the cancerous regions are also significantly lower than in the remainder of the breast(invasive ductal carcinoma:49±11%vs 61±16%,p<0.01;ductal carcinoma in situ:58±8%vs 77±11%,p<0.001). 展开更多
关键词 Diffuse spectral imaging near-infrared spectroscopy optical mammography OXIMETRY hemoglobin saturation
下载PDF
The meaning of “coherent” and its quantication in coherent hemodynamics spectroscopy
9
作者 Angelo Sassaroli Kristen Tgavalekos sergio fantini 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2018年第6期55-77,共23页
We have recently introduced a new technique,coherent hemodynamics spectroscopy(CHS),which aims at characterizing a specic kind of tissue hemodynamics that feature a high level of covariation with a given physiological... We have recently introduced a new technique,coherent hemodynamics spectroscopy(CHS),which aims at characterizing a specic kind of tissue hemodynamics that feature a high level of covariation with a given physiological quantity.In this study,we carry out a detailed analysis of the signicance of coherence and phase synchronization between oscillations of arterial blood pressure(ABP)and total hemoglobin concentration([Hbt]),measured with near-infrared spectroscopy(NIRS)during a typical protocol for CHS,based on a cyclic thigh cuffocclusion and release.Even though CHS is based on a linear time invariant model between ABP(input)and NIRS measurands(outputs),for practical reasons in a typical CHS protocol,we inducenite“groups”of ABP oscillations,in which each group is characterized by a different frequency.For this reason,ABP(input)and NIRS measurands(output)are not stationary processes,and we have used wavelet coherence and phase synchronization index(PSI),as a metric of coherence and phase synchronization,respectively.PSI was calculated by using both the wavelet cross spectrum and the Hilbert transform.We have also used linear coherence(which requires stationary process)for comparison with wavelet coherence.Themethod of surrogate data is used tond critical values for the signicance of covariation between ABP and[Hbt].Because we have found similar critical values for wavelet coherence and PSI by usingve of the most used methods of surrogate data,we propose to use the data-independent Gaussian random numbers(GRNs),for CHS.By using wavelet coherence and wavelet cross spectrum,and GRNs as surrogate data,we have found the same results for the signicance of coherence and phase synchronization between ABP and[Hbt]:on a total set of 20 periods of cuffoscillations,we have found 17 coherent oscillations and 17 phase synchronous oscillations.Phase synchronization assessed with Hilbert transform yielded similar results with 14 phase synchronous oscillations.Linear coherence and wavelet coherence overall yielded similar number of signicant values.We discuss possible reasons for this result.Despite the similarity of linear and wavelet coherence,we argue that wavelet coherence is preferable,especially if one wants to use baseline spontaneous oscillations,in which phase locking and coherence between signals might be only temporary. 展开更多
关键词 Wavelet coherence phase synchronization near-infrared spectroscopy surrogate data
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部