The water equivalent ratio(WER) was calculated for polypropylene(PP), paraffin, polyethylene(PE), polystyrene(PS), polymethyl methacrylate(PMMA), and polycarbonate materials with potential applications in dosimetry an...The water equivalent ratio(WER) was calculated for polypropylene(PP), paraffin, polyethylene(PE), polystyrene(PS), polymethyl methacrylate(PMMA), and polycarbonate materials with potential applications in dosimetry and medical physics. This was performed using the Monte Carlo simulation code, MCNPX, at different proton energies. The calculated WER values were compared with National Institute of Standards and Technology(NIST) data, available experimental and analytical results,as well as the FLUKA, SRIM, and SEICS codes. PP and PMMA were associated with the minimum and maximum WER values, respectively. Good agreement was observed between the MCNPX and NIST data. The biggest difference was 0.71% for PS at 150 MeV proton energy. In addition, a relatively large positive correlation between the WER values and the electron density of the dosimetric materials was observed. Finally, it was noted that PE presented the most analogous Depth Dose Characteristics to liquid water.展开更多
Amino acids are the building blocks of proteins,which are the most abundant macromolecules in living cells.From the standpoint of the photon interaction cross sections of amino acids,the mass attenuation coefficients,...Amino acids are the building blocks of proteins,which are the most abundant macromolecules in living cells.From the standpoint of the photon interaction cross sections of amino acids,the mass attenuation coefficients,half and tenth value layers,mean free path,effective atomic and electronic cross sections,effective atomic number,and effective electron density of fifteen essential amino acids have been determined for 133Ba,137Cs,and 60Co gamma-ray sources.The MCNP-4C code and the XCOM program have been used to calculate these parameters.The results have been compared to the available experimental and theoretical data.The theoretical results agreed with the experimental data,with RD values of ≤±7%.In the energy region of 81-1332.5 keV,it was found that the μm,σa,and revalues of the amino acids decreased as the photon energy increased,and the increasing density of amino acids had no steady effect on these quantities.Additionally,results demonstrated that the HVL,TVL,and MFP values increased with the increase in photon energy.The μm,σa,and Zeff values of aspartic acid were the highest among those of all amino acids,and they were the lowest for isoleucine.The Zeff value of each sample containing H,C,N,and O atoms was nearly constant in the studied energy region.The Neffvalues of the studied amino acids varied in the range of 3.14×10^23-3.44×10^23 electron/g.Furthermore,the Neffvalues were approximately independent of the amino acid type in this energy region.展开更多
文摘The water equivalent ratio(WER) was calculated for polypropylene(PP), paraffin, polyethylene(PE), polystyrene(PS), polymethyl methacrylate(PMMA), and polycarbonate materials with potential applications in dosimetry and medical physics. This was performed using the Monte Carlo simulation code, MCNPX, at different proton energies. The calculated WER values were compared with National Institute of Standards and Technology(NIST) data, available experimental and analytical results,as well as the FLUKA, SRIM, and SEICS codes. PP and PMMA were associated with the minimum and maximum WER values, respectively. Good agreement was observed between the MCNPX and NIST data. The biggest difference was 0.71% for PS at 150 MeV proton energy. In addition, a relatively large positive correlation between the WER values and the electron density of the dosimetric materials was observed. Finally, it was noted that PE presented the most analogous Depth Dose Characteristics to liquid water.
文摘Amino acids are the building blocks of proteins,which are the most abundant macromolecules in living cells.From the standpoint of the photon interaction cross sections of amino acids,the mass attenuation coefficients,half and tenth value layers,mean free path,effective atomic and electronic cross sections,effective atomic number,and effective electron density of fifteen essential amino acids have been determined for 133Ba,137Cs,and 60Co gamma-ray sources.The MCNP-4C code and the XCOM program have been used to calculate these parameters.The results have been compared to the available experimental and theoretical data.The theoretical results agreed with the experimental data,with RD values of ≤±7%.In the energy region of 81-1332.5 keV,it was found that the μm,σa,and revalues of the amino acids decreased as the photon energy increased,and the increasing density of amino acids had no steady effect on these quantities.Additionally,results demonstrated that the HVL,TVL,and MFP values increased with the increase in photon energy.The μm,σa,and Zeff values of aspartic acid were the highest among those of all amino acids,and they were the lowest for isoleucine.The Zeff value of each sample containing H,C,N,and O atoms was nearly constant in the studied energy region.The Neffvalues of the studied amino acids varied in the range of 3.14×10^23-3.44×10^23 electron/g.Furthermore,the Neffvalues were approximately independent of the amino acid type in this energy region.