The purpose of this research is to obtain the optimum cutting parameters to achieve the dimensional accuracy of Nimonic alloy miniature gear manufactured using Wire EDM.The cutting parameters investigated in this stud...The purpose of this research is to obtain the optimum cutting parameters to achieve the dimensional accuracy of Nimonic alloy miniature gear manufactured using Wire EDM.The cutting parameters investigated in this study are current,pulse on time(PON),pulse off time(POFF),wire tension(WT)and dielectric fluids.Ethylene glycol,nanopowder of alumina and oxygen are mixed to demineralized water to prepare novel dielectric fluids.Deviation in inner diameter,deviation in outer diameter,deviation in land and deviation in tooth width are considered to check the dimensional accuracy.Taguchi L_(16) is employed for experimental design and multiple response optimization is performed using Entropy TOPSIS and Pareto ANOVA.Results indicate that pulse on time is the most notable parameter for good dimensional accuracy followed by dielectric fluid,current,pulse off time and wire tension.Ethylene glycol mixed demineralized water is preferred for low dimensional deviation.The optimum WEDM parameters are pulse on time at 20μs,Ethylene glycol mixed demineralized water dielectric fluid,current at 3 A,pulse off time at 4μs,and wire tension at 18 N.展开更多
基金the Deanship of Scientific Research at King Khalid University,for funding this work through research groups program under Grant No.(R.G.P.1/197/41).
文摘The purpose of this research is to obtain the optimum cutting parameters to achieve the dimensional accuracy of Nimonic alloy miniature gear manufactured using Wire EDM.The cutting parameters investigated in this study are current,pulse on time(PON),pulse off time(POFF),wire tension(WT)and dielectric fluids.Ethylene glycol,nanopowder of alumina and oxygen are mixed to demineralized water to prepare novel dielectric fluids.Deviation in inner diameter,deviation in outer diameter,deviation in land and deviation in tooth width are considered to check the dimensional accuracy.Taguchi L_(16) is employed for experimental design and multiple response optimization is performed using Entropy TOPSIS and Pareto ANOVA.Results indicate that pulse on time is the most notable parameter for good dimensional accuracy followed by dielectric fluid,current,pulse off time and wire tension.Ethylene glycol mixed demineralized water is preferred for low dimensional deviation.The optimum WEDM parameters are pulse on time at 20μs,Ethylene glycol mixed demineralized water dielectric fluid,current at 3 A,pulse off time at 4μs,and wire tension at 18 N.