BACKGROUND: The resection and reconstruction of large vessels, including the portal vein, are frequently needed in tumor resection. Warm ischemia before reconstruction might have deleterious effects on the function o...BACKGROUND: The resection and reconstruction of large vessels, including the portal vein, are frequently needed in tumor resection. Warm ischemia before reconstruction might have deleterious effects on the function of some vital organs and therefore, how to reconstruct the vessels quickly after resection is extremely important. The present study was to introduce a new type of magnetic compression anastomosis (MCA) device to establish a quick non-suture anastomosis of the portal vein after resection in canines.展开更多
Objective To assese the healing of stoma after magnetic anastomosis for the reconstruction of biliary-enteric continuity under severe inflammation. Methods Acute bile duct injury was constructed as a bile peritonitis ...Objective To assese the healing of stoma after magnetic anastomosis for the reconstruction of biliary-enteric continuity under severe inflammation. Methods Acute bile duct injury was constructed as a bile peritonitis model in mongrel dogs(n=32). Magnetic anastomosis(group A, n=16) and traditional suture anastomosis(group B, n=16) were performed to reconstruct the biliary-enteric continuity in one stage. Half of the dogs in each group were euthanized on the 30 th postoperative day, and the other half on the 90 th postoperative day to harvest the stoma region. The healing conditions of the stoma after the 2 anastomotic approaches were observed with naked eyes, under light microscope and scanning electron microscope. Results The stoma leakage rate(50% versus 0% on the 30 th postoperative day, 37.5% versus 12.5% on the 90 th postoperative day, both P<0.05) and stenosis degree(13.9%±0.3% versus 7.1%±0.3% on the 30 th postoperative day, 17.2%±0.4% versus 9.4%±0.4% on the 90 th postoperative day, both P<0.01) were significantly higher in group B than in group A. Compared with traditional manual anastomoses, the histological analysis under light and electron microscope showed a more continuous stoma with more regular epithelium proliferation and collagen arrangement, less inflammation in group A. Conclusions Magnetic anastomosis stent ensures better healing of the stoma even under the circumstance of severe inflammation.展开更多
Background:Although laparoscopic technology has achieved rapid development in the surgical field,it has not been applied to liver transplantation,primarily because of difficulties associated with laparoscopic vascular...Background:Although laparoscopic technology has achieved rapid development in the surgical field,it has not been applied to liver transplantation,primarily because of difficulties associated with laparoscopic vascular anastomosis.In this study,we introduced a new magnetic-assisted vascular anastomosis technique and explored its application in laparoscopic liver transplantation in pigs.Methods:Two sets of magnetic vascular anastomosis rings(MVARs)with different diameters were developed.One set was used for anastomosis of the suprahepatic vena cava(SHVC)and the other set was used for anastomosis of the infrahepatic vena cava(IHVC)and portal vein(PV).Six laparoscopic orthotopic liver transplantations were performed in pigs.Donor liver was obtained via open surgery.Hepatectomy was performed in the recipients through laparoscopic surgery.Anastomosis of the SHVC was performed using hand-assisted magnetic anastomosis,and the anastomosis of the IHVC and PV was performed by magnetic anastomosis with or without hand assistance.Results:Liver transplants were successfully performed in five of the six cases.Postoperative ultrasonographic examination showed that the portal inflow was smooth.However,PV bending and blood flow obstruction occurred in one case because the MVARs were attached to each other.The durations of loading of MVAR in the laparoscope group and manual assistance group for IHVC and PV were 13±5 vs.5±1 min(P<0.01)and 10±2 vs.4±1 min(P<0.05),respectively.The durations of MVAR anastomosis in the laparoscope group and manual assistance group for IHVC and PV were 5±1 vs.1±1 min(P<0.01),and 5±1 vs.1±1 min(P<0.01),respectively.The anhepatic phase was 43±4 min in the laparoscope group and 23±2 min in the manual assistance group(P<0.01).Conclusions:Our study showed that magnetic-assisted laparoscopic liver transplantation can be successfully carried out in pigs.展开更多
To the Editor:Obesity is becoming a worldwide health issue,and the prevalence of obesity continues to increase.[1,2]Body weight reduction is one of the effective measures to solve this problem;however,only a small num...To the Editor:Obesity is becoming a worldwide health issue,and the prevalence of obesity continues to increase.[1,2]Body weight reduction is one of the effective measures to solve this problem;however,only a small number of obese patients succeed in controlling their body weight without intervention.Sleeve gastrectomy(SG)is widely performed in obese patients for its excellent surgical result and easy surgical procedures.Unfortunately,stomach leakage may cause severe consequences,such as infection and death,although the incidence rate of this complication is 2.4%.展开更多
基金supported by grants from the National Natural Science Foundation of China(30830099&81470896&81127005)the Science and Technology Co-ordinating Innovative Engineering Projects of Shaanxi Province(2014KTCQ03-05)
文摘BACKGROUND: The resection and reconstruction of large vessels, including the portal vein, are frequently needed in tumor resection. Warm ischemia before reconstruction might have deleterious effects on the function of some vital organs and therefore, how to reconstruct the vessels quickly after resection is extremely important. The present study was to introduce a new type of magnetic compression anastomosis (MCA) device to establish a quick non-suture anastomosis of the portal vein after resection in canines.
基金Supported by the National Natural Science Foundation of China(30830099)China Postdoctoral Science Foundation(20100481341)Scienceand Technology Research and Development Project of Shaanxi Province(2009K14-01)
文摘Objective To assese the healing of stoma after magnetic anastomosis for the reconstruction of biliary-enteric continuity under severe inflammation. Methods Acute bile duct injury was constructed as a bile peritonitis model in mongrel dogs(n=32). Magnetic anastomosis(group A, n=16) and traditional suture anastomosis(group B, n=16) were performed to reconstruct the biliary-enteric continuity in one stage. Half of the dogs in each group were euthanized on the 30 th postoperative day, and the other half on the 90 th postoperative day to harvest the stoma region. The healing conditions of the stoma after the 2 anastomotic approaches were observed with naked eyes, under light microscope and scanning electron microscope. Results The stoma leakage rate(50% versus 0% on the 30 th postoperative day, 37.5% versus 12.5% on the 90 th postoperative day, both P<0.05) and stenosis degree(13.9%±0.3% versus 7.1%±0.3% on the 30 th postoperative day, 17.2%±0.4% versus 9.4%±0.4% on the 90 th postoperative day, both P<0.01) were significantly higher in group B than in group A. Compared with traditional manual anastomoses, the histological analysis under light and electron microscope showed a more continuous stoma with more regular epithelium proliferation and collagen arrangement, less inflammation in group A. Conclusions Magnetic anastomosis stent ensures better healing of the stoma even under the circumstance of severe inflammation.
基金supported by a grant from the Key R&D Project of Shaanxi Province(No.2020GXLH-Z-001)。
文摘Background:Although laparoscopic technology has achieved rapid development in the surgical field,it has not been applied to liver transplantation,primarily because of difficulties associated with laparoscopic vascular anastomosis.In this study,we introduced a new magnetic-assisted vascular anastomosis technique and explored its application in laparoscopic liver transplantation in pigs.Methods:Two sets of magnetic vascular anastomosis rings(MVARs)with different diameters were developed.One set was used for anastomosis of the suprahepatic vena cava(SHVC)and the other set was used for anastomosis of the infrahepatic vena cava(IHVC)and portal vein(PV).Six laparoscopic orthotopic liver transplantations were performed in pigs.Donor liver was obtained via open surgery.Hepatectomy was performed in the recipients through laparoscopic surgery.Anastomosis of the SHVC was performed using hand-assisted magnetic anastomosis,and the anastomosis of the IHVC and PV was performed by magnetic anastomosis with or without hand assistance.Results:Liver transplants were successfully performed in five of the six cases.Postoperative ultrasonographic examination showed that the portal inflow was smooth.However,PV bending and blood flow obstruction occurred in one case because the MVARs were attached to each other.The durations of loading of MVAR in the laparoscope group and manual assistance group for IHVC and PV were 13±5 vs.5±1 min(P<0.01)and 10±2 vs.4±1 min(P<0.05),respectively.The durations of MVAR anastomosis in the laparoscope group and manual assistance group for IHVC and PV were 5±1 vs.1±1 min(P<0.01),and 5±1 vs.1±1 min(P<0.01),respectively.The anhepatic phase was 43±4 min in the laparoscope group and 23±2 min in the manual assistance group(P<0.01).Conclusions:Our study showed that magnetic-assisted laparoscopic liver transplantation can be successfully carried out in pigs.
基金This work was supported by grants from the Fundamental Research Funds for the Central Universities(No.xzy022019032)the Fundamental Research Funds for the Central Universities(No.xjj2018104)the Natural Science Basis Research Plan of Shaanxi Province(No.2019JQ-949)。
文摘To the Editor:Obesity is becoming a worldwide health issue,and the prevalence of obesity continues to increase.[1,2]Body weight reduction is one of the effective measures to solve this problem;however,only a small number of obese patients succeed in controlling their body weight without intervention.Sleeve gastrectomy(SG)is widely performed in obese patients for its excellent surgical result and easy surgical procedures.Unfortunately,stomach leakage may cause severe consequences,such as infection and death,although the incidence rate of this complication is 2.4%.