Electroanalysis and simultaneous determination of dopamine and epinephrine at poly(isonicotinic acid)-modified carbon paste electrode in the presence of ascorbic acid 被引量:4
1
作者 Yuan Zhen Zhou Li Juan Zhang +2 位作者 Shuang Li Chen she ying dong Xiao Hui Zheng 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期217-220,共4页
A carbon paste electrode modified with electropolymerized fills of isonicotinic acid was developed. The modified electrode shows excellent electrocatalytic activity toward the oxidation of both dopamine (DA) and epi... A carbon paste electrode modified with electropolymerized fills of isonicotinic acid was developed. The modified electrode shows excellent electrocatalytic activity toward the oxidation of both dopamine (DA) and epinephrine (EP). Separation of the reduction peak potentials for dopamine and epinephrine was about 357 mV in pH 5.3 phosphate buffer solution (PBS) and the character was used for the detection DA and EP simultaneously. The peak currents increase linearly with DA and EP concentration over the range of 8.0×10^-5 to 7.0×10^-4 mol/L and 5.0×10^-6 to 1.0×10^-4 mol/L with detection limits of 2×10^-5 and 1×10^-6 mol/L, respectively. The interference studies showed that the modified electrode exhibits excellent selectivity in the presence of large excess of ascorbic acid (AA). 展开更多
关键词 DOPAMINE EPINEPHRINE Isonicotinic acid Ascorbic acid Simultaneous determination
下载PDF
The Investigation of Oscillographic Chronopotentiometry at Silver Disk Electrode and Its Mechanism
2
作者 she ying dong Ke Qi YU +1 位作者 Hong sheng TANG Hong GAO(Institute of Analytical Science, Northwest University, Xi’an 710069Graduate School, University of Science & TecnoLogy of China, Beijing 100039) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第7期615-616,共2页
A new method of oscillographic chronopotentiometry at silver disk electrode was investigated. By using it, a series of ions such as Pb, In, Cr, Tl, Bi etc. were determined. The detection limits are two or three orders... A new method of oscillographic chronopotentiometry at silver disk electrode was investigated. By using it, a series of ions such as Pb, In, Cr, Tl, Bi etc. were determined. The detection limits are two or three orders of magnitude lower than those by oscillographic chronopotentiometry at mercury electrode. The proposed method is characterized by fine sensitivity, stable oscillogram and no mercury. The research on the mechanism of this method shows that these achievements are caused by the characterristics of silver electroxidation and electroreduction and the oscillographic chronopotentiometry (OC). 展开更多
关键词 silver disk electrode oscillographic determination oscillographic chronopotentiometry
下载PDF