In this work,a new hybrid MPGD consisting of two GEM foils and a metallic mesh was proposed.Based on the simulation studies,this design can significantly reduce the rise time of signal and has a better performance in ...In this work,a new hybrid MPGD consisting of two GEM foils and a metallic mesh was proposed.Based on the simulation studies,this design can significantly reduce the rise time of signal and has a better performance in respect of particle identification compared with the triple GEM design.The gain with various voltages setting was computed in order to provide us references for future experiment.The simulation results also show that the time and space resolution compared to the triple GEM detector are also improved.The time and space resolution of hybrid detector with Ar/CO_2(70/30) and Ar/isobutane(95/5) were investigated for various drift electric field intensities.This new hybrid detector shows excellent potential for both fundamental research and imaging applications.展开更多
In this paper, a novel system using direct contact heat transfer between air and water solution was proposed to generate ice slurry. The heat transfer process and the system performance were studied; energy efficiency...In this paper, a novel system using direct contact heat transfer between air and water solution was proposed to generate ice slurry. The heat transfer process and the system performance were studied; energy efficiency coefficients of 0.038, 0.053, and 0.064 were obtained using different solutions. An empirical relationship between the volumetric heat transfer coefficient U v and the main parameters was obtained by fitting the experimental data. The U v calculated from the empirical formula agreed with the experimental U v quite well with a relative error of less than 15%. Based on the empirical formula, a laboratory-scale direct contact ice slurry generator was then constructed, with practical application in mind. If the air flow rate is fixed at 200 m 3 /h, the ice production rate will be 0.091 kg/min. The experimental results also showed that the cold energy consumption of the air compressor accounted for more than half of the total amount. To improve the system energy efficiency coefficient, it is necessary to increase the air pipes insulation and the solution's thermal capacity, and also it is appropriate to utilize the free cold energy of liquefied natural gas (LNG).展开更多
The acoustic field of a linear compressor serves to deliver the compression work to the load, such as the connected cold head of a cryocooler; it plays an equivalently important role as the electrical and mechanical p...The acoustic field of a linear compressor serves to deliver the compression work to the load, such as the connected cold head of a cryocooler; it plays an equivalently important role as the electrical and mechanical parts, especially in the impedance match issue. This paper studies the acoustic impedance characteristics of a linear compressor. The parameters including the current, the piston displacement, the pressure amplitude, the electrical power dissipation, the power factor, the pressure-volumetric (PV) power delivered, and the efficiency are theoretically and experimentally investigated. Different from previous theoretical studies, optimization for the operations away from the resonance is also included. More general optimization results imply relevance between thermoacoustic engines and linear compressors. The predicted results are validated by the experiments performed on a linear compressor with an adjustable resistive-capacitive (RC) acoustic load. The comparisons between the calculations and the measurements are presented and analyzed. The results provide deeper insight into the mechanism of the linear compressor and the impedance match in a cryocooler system.展开更多
基金Supported by the National Natural Science Foundation of China(Nos.11135002,11275235,11405077 and 11575073)
文摘In this work,a new hybrid MPGD consisting of two GEM foils and a metallic mesh was proposed.Based on the simulation studies,this design can significantly reduce the rise time of signal and has a better performance in respect of particle identification compared with the triple GEM design.The gain with various voltages setting was computed in order to provide us references for future experiment.The simulation results also show that the time and space resolution compared to the triple GEM detector are also improved.The time and space resolution of hybrid detector with Ar/CO_2(70/30) and Ar/isobutane(95/5) were investigated for various drift electric field intensities.This new hybrid detector shows excellent potential for both fundamental research and imaging applications.
基金Project (No. 51176164) supported by the National Natural Science Foundation of China
文摘In this paper, a novel system using direct contact heat transfer between air and water solution was proposed to generate ice slurry. The heat transfer process and the system performance were studied; energy efficiency coefficients of 0.038, 0.053, and 0.064 were obtained using different solutions. An empirical relationship between the volumetric heat transfer coefficient U v and the main parameters was obtained by fitting the experimental data. The U v calculated from the empirical formula agreed with the experimental U v quite well with a relative error of less than 15%. Based on the empirical formula, a laboratory-scale direct contact ice slurry generator was then constructed, with practical application in mind. If the air flow rate is fixed at 200 m 3 /h, the ice production rate will be 0.091 kg/min. The experimental results also showed that the cold energy consumption of the air compressor accounted for more than half of the total amount. To improve the system energy efficiency coefficient, it is necessary to increase the air pipes insulation and the solution's thermal capacity, and also it is appropriate to utilize the free cold energy of liquefied natural gas (LNG).
基金supported by the National Natural Science Foundation of China (No. 51176165)the Open Project Program of the Key Laboratory of Infrared Imaging Materials and Detectors (No. IIMDKFJJ-11-07), China
文摘The acoustic field of a linear compressor serves to deliver the compression work to the load, such as the connected cold head of a cryocooler; it plays an equivalently important role as the electrical and mechanical parts, especially in the impedance match issue. This paper studies the acoustic impedance characteristics of a linear compressor. The parameters including the current, the piston displacement, the pressure amplitude, the electrical power dissipation, the power factor, the pressure-volumetric (PV) power delivered, and the efficiency are theoretically and experimentally investigated. Different from previous theoretical studies, optimization for the operations away from the resonance is also included. More general optimization results imply relevance between thermoacoustic engines and linear compressors. The predicted results are validated by the experiments performed on a linear compressor with an adjustable resistive-capacitive (RC) acoustic load. The comparisons between the calculations and the measurements are presented and analyzed. The results provide deeper insight into the mechanism of the linear compressor and the impedance match in a cryocooler system.