In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a...In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method.展开更多
A detector setup for the measurement of angular distribution of heavy-ion elastic scattering at energies around Coulomb barrier on the radioactive ion beam line in Lanzhou at the heavy-ion research facility in Lanzhou...A detector setup for the measurement of angular distribution of heavy-ion elastic scattering at energies around Coulomb barrier on the radioactive ion beam line in Lanzhou at the heavy-ion research facility in Lanzhou is designed.The beam profile and the scattering angles on the target are deduced by two parallel plate avalanche counters,and four sets of detector telescopes(including doublesided silicon strip detectors) are placed systematically with the beam line,incorporating with Monte Carlo simulations.The data of ^(16)O on ^(89)Y target were analyzed to compare with the simulation results.It is found that the simulated distribution is agreeable with the experimental data.By assuming the pure Rutherford scattering at small scattering angles,the angular distribution of elastic scattering of^(16)O+^(89)Y at low energies can be reasonably obtained.It indicates that this set of detector setup can be used for the measurement of angular distributions of heavy-ion elastic scattering at energies around Coulomb barrier.展开更多
The elastic scattering angular distributions of ^(13)C at 340 MeV and ^(14)C at 294 MeV and 342 MeV on a ^(208)Pb target,which correspond to approximately five times the Coulomb barriers,were measured at the Radioacti...The elastic scattering angular distributions of ^(13)C at 340 MeV and ^(14)C at 294 MeV and 342 MeV on a ^(208)Pb target,which correspond to approximately five times the Coulomb barriers,were measured at the Radioactive Ion Beam Line in Lanzhou.The data were analyzed within the optical model and continuum-discretized coupled-channels(CDCC)framework,and the results of both calculations could effectively account for the experimental data.The differential cross sections of elastic scattering revealed no particular suppression at the Coulomb nuclear interference peak angles,suggesting that the breakup coupling effects on the elastic scattering angular distributions were negligibly small in this incident energy region.The contributions from the couplings with inelastic states to the elastic cross sections were of minor importance within the angular range covered by these experiments.展开更多
Elastic scattering of 10Be on a 208Pb target was measured at ELab=127 MeV,which corresponds to three times the Coulomb barrier.The secondary 10Be beam was produced at the Radioactive Ion Beam Line in Lanzhou of the He...Elastic scattering of 10Be on a 208Pb target was measured at ELab=127 MeV,which corresponds to three times the Coulomb barrier.The secondary 10Be beam was produced at the Radioactive Ion Beam Line in Lanzhou of the Heavy-Ion Research Facility in Lanzhou.The angular distribution of elastic scattering in the 10 Be+208Pb system shows a typical Fresnel diffraction peak.Optical model analysis of the angular distribution was performed using the Woods-Saxon,double-folding and global potentials.With the global potential,different density distributions were used.The results indicate that different density distributions for the projectile induce distinct effects in the angular distribution.展开更多
基金supported by the National Natural Science Foundation of China (Nos.12275007, U1867214, 11775004)the funding from the State Key Laboratory of Nuclear Physics and Technology,Peking University,China (No. NPT2021ZZ01)funding from heavy Ion Research Facility,Lanzhou,China (No. HIR2021PY002)。
文摘In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method.
基金Supported by the National Natural Science Foundation of China(Nos.11475013,11175011,11035007)
文摘A detector setup for the measurement of angular distribution of heavy-ion elastic scattering at energies around Coulomb barrier on the radioactive ion beam line in Lanzhou at the heavy-ion research facility in Lanzhou is designed.The beam profile and the scattering angles on the target are deduced by two parallel plate avalanche counters,and four sets of detector telescopes(including doublesided silicon strip detectors) are placed systematically with the beam line,incorporating with Monte Carlo simulations.The data of ^(16)O on ^(89)Y target were analyzed to compare with the simulation results.It is found that the simulated distribution is agreeable with the experimental data.By assuming the pure Rutherford scattering at small scattering angles,the angular distribution of elastic scattering of^(16)O+^(89)Y at low energies can be reasonably obtained.It indicates that this set of detector setup can be used for the measurement of angular distributions of heavy-ion elastic scattering at energies around Coulomb barrier.
基金Supported by the National Natural Science Foundation of China (12122511,12105330)the Youth Innovation Promotion Association CAS (2020411)+1 种基金funding from the State Key Laboratory of Nuclear Physics and Technology,Peking University (NPT2023KFY04)V.G.would like to thank CNPq (303769/2021-1).
文摘The elastic scattering angular distributions of ^(13)C at 340 MeV and ^(14)C at 294 MeV and 342 MeV on a ^(208)Pb target,which correspond to approximately five times the Coulomb barriers,were measured at the Radioactive Ion Beam Line in Lanzhou.The data were analyzed within the optical model and continuum-discretized coupled-channels(CDCC)framework,and the results of both calculations could effectively account for the experimental data.The differential cross sections of elastic scattering revealed no particular suppression at the Coulomb nuclear interference peak angles,suggesting that the breakup coupling effects on the elastic scattering angular distributions were negligibly small in this incident energy region.The contributions from the couplings with inelastic states to the elastic cross sections were of minor importance within the angular range covered by these experiments.
基金Supported by the National Natural Science Foundation of China(U1632138,11575256,11605253,11705242,11875297)
文摘Elastic scattering of 10Be on a 208Pb target was measured at ELab=127 MeV,which corresponds to three times the Coulomb barrier.The secondary 10Be beam was produced at the Radioactive Ion Beam Line in Lanzhou of the Heavy-Ion Research Facility in Lanzhou.The angular distribution of elastic scattering in the 10 Be+208Pb system shows a typical Fresnel diffraction peak.Optical model analysis of the angular distribution was performed using the Woods-Saxon,double-folding and global potentials.With the global potential,different density distributions were used.The results indicate that different density distributions for the projectile induce distinct effects in the angular distribution.