期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Image matching algorithm based on SIFT using color and exposure information 被引量:9
1
作者 Yan Zhao Yuwei Zhai +1 位作者 Eric Dubois shigang wang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2016年第3期691-699,共9页
Image matching based on scale invariant feature transform(SIFT) is one of the most popular image matching algorithms, which exhibits high robustness and accuracy. Grayscale images rather than color images are genera... Image matching based on scale invariant feature transform(SIFT) is one of the most popular image matching algorithms, which exhibits high robustness and accuracy. Grayscale images rather than color images are generally used to get SIFT descriptors in order to reduce the complexity. The regions which have a similar grayscale level but different hues tend to produce wrong matching results in this case. Therefore, the loss of color information may result in decreasing of matching ratio. An image matching algorithm based on SIFT is proposed, which adds a color offset and an exposure offset when converting color images to grayscale images in order to enhance the matching ratio. Experimental results show that the proposed algorithm can effectively differentiate the regions with different colors but the similar grayscale level, and increase the matching ratio of image matching based on SIFT. Furthermore, it does not introduce much complexity than the traditional SIFT. 展开更多
关键词 scale invariant feature transform(SIFT) image matching color exposure
下载PDF
Computational fluid dynamics analysis and experimental hemolytic performance of three clinical centrifugal blood pumps: Revolution, Rotaflow and CentriMag
2
作者 Dong Han Joshua L.Leibowitz +4 位作者 Lu Han shigang wang Ge He Bartley P.Griffith Zhongjun J.Wu 《Medicine in Novel Technology and Devices》 2022年第3期107-114,共8页
Centrifugal blood pumps have become popular for adult extracorporeal membrane oxygenation(ECMO)due to their superior blood handling and reduced thrombosis risk featured by their secondary flow paths that avoid stagnan... Centrifugal blood pumps have become popular for adult extracorporeal membrane oxygenation(ECMO)due to their superior blood handling and reduced thrombosis risk featured by their secondary flow paths that avoid stagnant areas.However,the high rotational speed within a centrifugal blood pump can introduce high shear stress,causing a significant shear-induced hemolysis rate.The Revolution pump,the Rotaflow pump,and the CentriMag pump are three of the leading centrifugal blood pumps on the market.Although many experimental and computational studies have focused on evaluating the hydraulic and hemolytic performances of the Rotaflow and CentriMag pumps,there are few on the Revolution pump.Furthermore,a thorough direct comparison of these three pumps'flow characteristics and hemolysis is not available.In this study,we conducted a computational and experimental analysis to compare the hemolytic performances of the Revolution,Rotaflow,and CentriMag pumps operating under a clinically relevant condition,i.e.,the blood flow rate of 5 L/min and pump pressure head of 350 mmHg,for adult ECMO support.In silico simulations were used to characterize the shear stress distributions and predict the hemolysis index,while in vitro blood loop studies experimentally determined hemolysis performance.Comparative simulation results and experimental data demonstrated that the CentriMag pump caused the lowest hemolysis while the Revolution pump generated the highest hemolysis. 展开更多
关键词 CFD ECMO support Centrifugal blood pumps HEMOLYSIS
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部