It is necessary to investigate the wavelength-dependent variation rules of the refractive index of edible oils so as to explore the specificity of the dispersion in light propagation,imaging,and interference processes...It is necessary to investigate the wavelength-dependent variation rules of the refractive index of edible oils so as to explore the specificity of the dispersion in light propagation,imaging,and interference processes among different types of edible oil products.In this study,by deriving the refractive index equations of the double glass sheet holding device and oil,the reflectance spectra of three different types of oil samples,namely,peanut oil,colza oil,and kitchen waste oil,were measured via a spectrometer.Furthermore,the refractive index model of these different types of oil samples was investigated.Additionally,based on the oil dispersion characteristics,the dis-persion of oil in optical coherence tomography(OCT)was compensated via deconvolution.In the wavelength range of λ∈(380,1500)nm,the analytical expressions of the double glass sheet holding device and oils are featured by practical reliability.The refractive indexes of three different types of oils n∈(1.38,1.52)show normal dispersion characteristics.The Cauchy co-efficient matrix of the oil refractive index can be used for oil identification;in particular,the healthy oil and waste oil differ significantly in terms of the Cauchy coefficient matrix in the infrared band.Oil dispersion has almost no influence on the phase spectra of oils but can enhance their amplitude spectra.The dispersion mismatch can be eliminated by calculating the convo-lution kernel.The envelope broadening factors of OCT interference signals of oil products are 0.84,0.64,and 0.91,respectively.According to the present research results,the refractive index model of oil can effectively remove the influence of the holding device.The refractive indexes of three different types of oil samples show similar wavelength-dependent variation characteristics,which confirms the existence of many correlated components in these oil samples.The established refractive index model of oil in a wide spectral range,from the ultraviolet to the infrared band,can be adequately employed for identifying different types of oils.The numerical dispersion compensation based on the established refractive index model can enhance the axial resolution in OCT imaging.展开更多
A novel 2×5 model of insert-plug piezoelectric quartz crystal tumor marker micro-array immunosensor constructed with screw clamp apparatus has been developed for quantitative detection of the tumor markers such a...A novel 2×5 model of insert-plug piezoelectric quartz crystal tumor marker micro-array immunosensor constructed with screw clamp apparatus has been developed for quantitative detection of the tumor markers such as alpha-fetoprotein (AFP),carcino-embryonic antigen (CEA),prostate specific antigen (PSA),and human chorionic gonadotropin (hCG) in serum,in which every crystal unit can oscillate independently with the stability of±1 hertz (Hz) in air and±2 Hz in liquid.These response characteristics of Pz tumor marker micro-array immunosensor such as temperature, time-cost,reproducibility and specificity etc were also investigated.The detection ranges for AFP,CEA,PSA,and hCG obtained by Pz micro-array immunosensor were 20 ng/ml~640 ng/ml,1.56 ng/ml~50 ng/ml,1.25 ng/ml~50 ng/ml,and 2.5 mIU/ml~250 mlU/mi respectively with the coefficient of variance (CV) less than 5%.No cross-reactivates with other tumor markers in serum were observed.The results of AFP,CEA,PSA,and hCG obtained by this method from 68 serum samples were in good agreement with those given by chemiluminescence immunoassay with the correlation coefficients of 0.92,0.90,0.91,and 0.94 respectively.The Pz immunosensor regenerated by urea solution could be reused for five times without appreciable loss of response activity.Therefore,the proposed insert-plug immunosensor provides a rapid, sensitive,specific,reusable,convenient and reliable alternative for the detection of tumor markers in clinical laboratory.展开更多
Catenated cages are generally considered thermodynamically more stable than their constituent monomeric cages.However,the catenation mechanism is yet to be elucidated;it would require systematic investigation into the...Catenated cages are generally considered thermodynamically more stable than their constituent monomeric cages.However,the catenation mechanism is yet to be elucidated;it would require systematic investigation into the structural effects of the building blocks,their enthalpic and entropic contributions,and the effect of solvents.By inspecting these factors,we rationalized some design principles for the efficient construction of catenated cages.展开更多
文摘It is necessary to investigate the wavelength-dependent variation rules of the refractive index of edible oils so as to explore the specificity of the dispersion in light propagation,imaging,and interference processes among different types of edible oil products.In this study,by deriving the refractive index equations of the double glass sheet holding device and oil,the reflectance spectra of three different types of oil samples,namely,peanut oil,colza oil,and kitchen waste oil,were measured via a spectrometer.Furthermore,the refractive index model of these different types of oil samples was investigated.Additionally,based on the oil dispersion characteristics,the dis-persion of oil in optical coherence tomography(OCT)was compensated via deconvolution.In the wavelength range of λ∈(380,1500)nm,the analytical expressions of the double glass sheet holding device and oils are featured by practical reliability.The refractive indexes of three different types of oils n∈(1.38,1.52)show normal dispersion characteristics.The Cauchy co-efficient matrix of the oil refractive index can be used for oil identification;in particular,the healthy oil and waste oil differ significantly in terms of the Cauchy coefficient matrix in the infrared band.Oil dispersion has almost no influence on the phase spectra of oils but can enhance their amplitude spectra.The dispersion mismatch can be eliminated by calculating the convo-lution kernel.The envelope broadening factors of OCT interference signals of oil products are 0.84,0.64,and 0.91,respectively.According to the present research results,the refractive index model of oil can effectively remove the influence of the holding device.The refractive indexes of three different types of oil samples show similar wavelength-dependent variation characteristics,which confirms the existence of many correlated components in these oil samples.The established refractive index model of oil in a wide spectral range,from the ultraviolet to the infrared band,can be adequately employed for identifying different types of oils.The numerical dispersion compensation based on the established refractive index model can enhance the axial resolution in OCT imaging.
文摘A novel 2×5 model of insert-plug piezoelectric quartz crystal tumor marker micro-array immunosensor constructed with screw clamp apparatus has been developed for quantitative detection of the tumor markers such as alpha-fetoprotein (AFP),carcino-embryonic antigen (CEA),prostate specific antigen (PSA),and human chorionic gonadotropin (hCG) in serum,in which every crystal unit can oscillate independently with the stability of±1 hertz (Hz) in air and±2 Hz in liquid.These response characteristics of Pz tumor marker micro-array immunosensor such as temperature, time-cost,reproducibility and specificity etc were also investigated.The detection ranges for AFP,CEA,PSA,and hCG obtained by Pz micro-array immunosensor were 20 ng/ml~640 ng/ml,1.56 ng/ml~50 ng/ml,1.25 ng/ml~50 ng/ml,and 2.5 mIU/ml~250 mlU/mi respectively with the coefficient of variance (CV) less than 5%.No cross-reactivates with other tumor markers in serum were observed.The results of AFP,CEA,PSA,and hCG obtained by this method from 68 serum samples were in good agreement with those given by chemiluminescence immunoassay with the correlation coefficients of 0.92,0.90,0.91,and 0.94 respectively.The Pz immunosensor regenerated by urea solution could be reused for five times without appreciable loss of response activity.Therefore,the proposed insert-plug immunosensor provides a rapid, sensitive,specific,reusable,convenient and reliable alternative for the detection of tumor markers in clinical laboratory.
基金supported by the National Natural Science Foundation of China(key program 21890733)and the Shanghai Natural Science Foundation(no.18ZR1420800).
文摘Catenated cages are generally considered thermodynamically more stable than their constituent monomeric cages.However,the catenation mechanism is yet to be elucidated;it would require systematic investigation into the structural effects of the building blocks,their enthalpic and entropic contributions,and the effect of solvents.By inspecting these factors,we rationalized some design principles for the efficient construction of catenated cages.