Lymph node (LN) metastases from hepatocellular carcinoma (HCC) are considered uncommon. We describe the surgical resection of a solitary para-aortic LN metastasis from HCC. A 65-year-old Japanese man with B-type liver...Lymph node (LN) metastases from hepatocellular carcinoma (HCC) are considered uncommon. We describe the surgical resection of a solitary para-aortic LN metastasis from HCC. A 65-year-old Japanese man with B-type liver cirrhosis was admitted for the evaluation of a liver tumor. He had already undergone radiofrequency ablation, transcatheter arterial chemoembolization, and percutaneous ethanol injection therapy for HCC. Despite treatment, viable regions remained in segments 4 and 8. We performed a right paramedian sectionectomy with partial resection of the left paramedian section of the liver. Six months later, serum concentrations of alpha-fetoprotein (189 ng/mL) and PIVKA-2 (507 mAU/mL) increased. Enhanced com- puted tomography of the abdomen revealed a tumor (20 mm in diameter) on the right side of the abdominal aorta. Fluorine-18 fluorodeoxyglucose positron emission tomography revealed an increased standard uptake value. There was no evidence of recurrence in other regions. Esophagogastroduodenoscopy and colonoscopy revealed no malignant tumor in the gastrointestinal tract. Para-aortic LN metastasis from HCC was thus diagnosed. We performed lymphadenectomy. Histopathological examination revealed that the tumor was largely necrotic, with poorly differentiated HCC on its surface, which confirmed the suspected diagnosis. After 6 mo tumor marker levels were normal, with no evidence of recurrence. Our experience suggests that a solitary para-aortic LN metastasis from HCC can be treated surgically.展开更多
This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatmen...This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is · exible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy.展开更多
文摘Lymph node (LN) metastases from hepatocellular carcinoma (HCC) are considered uncommon. We describe the surgical resection of a solitary para-aortic LN metastasis from HCC. A 65-year-old Japanese man with B-type liver cirrhosis was admitted for the evaluation of a liver tumor. He had already undergone radiofrequency ablation, transcatheter arterial chemoembolization, and percutaneous ethanol injection therapy for HCC. Despite treatment, viable regions remained in segments 4 and 8. We performed a right paramedian sectionectomy with partial resection of the left paramedian section of the liver. Six months later, serum concentrations of alpha-fetoprotein (189 ng/mL) and PIVKA-2 (507 mAU/mL) increased. Enhanced com- puted tomography of the abdomen revealed a tumor (20 mm in diameter) on the right side of the abdominal aorta. Fluorine-18 fluorodeoxyglucose positron emission tomography revealed an increased standard uptake value. There was no evidence of recurrence in other regions. Esophagogastroduodenoscopy and colonoscopy revealed no malignant tumor in the gastrointestinal tract. Para-aortic LN metastasis from HCC was thus diagnosed. We performed lymphadenectomy. Histopathological examination revealed that the tumor was largely necrotic, with poorly differentiated HCC on its surface, which confirmed the suspected diagnosis. After 6 mo tumor marker levels were normal, with no evidence of recurrence. Our experience suggests that a solitary para-aortic LN metastasis from HCC can be treated surgically.
文摘This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is · exible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy.