期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Urgent endoscopic ultrasound-guided choledochoduodenostomy for acute obstructive suppurative cholangitis-induced sepsis 被引量:18
1
作者 Kosuke Minaga Masayuki Kitano +7 位作者 Hajime Imai Kentaro Yamao Ken Kamata Takeshi Miyata shunsuke omoto Kumpei Kadosaka Tomoe Yoshikawa Masatoshi Kudo 《World Journal of Gastroenterology》 SCIE CAS 2016年第16期4264-4269,共6页
Acute obstructive suppurative cholangitis(AOSC) due to biliary lithiasis is a life-threatening condition that requires urgent biliary decompression. Although endoscopic retrograde cholangiopancreatography(ERCP) with s... Acute obstructive suppurative cholangitis(AOSC) due to biliary lithiasis is a life-threatening condition that requires urgent biliary decompression. Although endoscopic retrograde cholangiopancreatography(ERCP) with stent placement is the current gold standard for biliary decompression, it can sometimes be difficult because of failed biliary cannulation. In this retrospective case series, we describe three cases of successful biliary drainage with recovery from septic shock after urgent endoscopic ultrasound-guided choledochoduodenostomy(EUS-CDS) was performed for AOSC due to biliary lithiasis. In all three cases, technical success in inserting the stents was achieved and the patients completely recovered from AOSC with sepsis in a few days after EUS-CDS. There were no procedure-related complications. When initial ERCP fails, EUS-CDS can be an effective life-saving endoscopic biliary decompression procedure that shortens the procedure time and prevents post-ERCP pancreatitis, particularly in patients with AOSC-induced sepsis. 展开更多
关键词 ENDOSCOPIC ULTRASOUND-GUIDED biliary drainage CHOLEDOCHODUODENOSTOMY Acute OBSTRUCTIVE SUPPURATIVE c
下载PDF
Contrast-enhanced harmonic endoscopic ultrasonography for assessment of lymph node metastases in pancreatobiliary carcinoma 被引量:8
2
作者 Takeshi Miyata Masayuki Kitano +10 位作者 shunsuke omoto Kumpei Kadosaka Ken Kamata Hajime Imai Hiroki Sakamoto Naoshi Nisida Yogesh Harwani Takamichi Murakami Yoshifumi Takeyama Yasutaka Chiba Masatoshi Kudo 《World Journal of Gastroenterology》 SCIE CAS 2016年第12期3381-3391,共11页
AIM: To assess the usefulness of contrast-enhanced harmonic endoscopic ultrasonography(CH-EUS) for lymph node metastasis in pancreatobiliary carcinoma.METHODS: All patients suspected of pancreatobiliary carcinoma with... AIM: To assess the usefulness of contrast-enhanced harmonic endoscopic ultrasonography(CH-EUS) for lymph node metastasis in pancreatobiliary carcinoma.METHODS: All patients suspected of pancreatobiliary carcinoma with visible lymph nodes after standard EUS between June, 2009 and January, 2012 were enrolled.In the primary analysis, patients with successful EUSfine needle aspiration(FNA) were included. The lymph nodes were assessed by several standard EUS variables(short and long axis lengths, shape, edge characteristic and echogenicity), color Doppler EUS variable [central intranodal blood vessel(CIV) presence] and CH-EUS variable(heterogeneous/homogeneous enhancement patterns). The diagnostic accuracy relative to EUSFNA was calculated. In the second analysis, N-stage diagnostic accuracy of CH-EUS was compared with EUS-FNA in patients who underwent surgical resection.RESULTS: One hundred and nine patients(143 lymph nodes) fulfilled the criteria. The short axis cutoff ≥ 13 mm predicted malignancy with a sensitivity and specificity of 72% and 85%, respectively. These values were 72% and 63% for the long axis cut-off ≥ 20 mm, 62% and 75% for the round shape variable, 81% and 30% for the sharp edge variable, 66% and 61% for the hypoechogenicity variable, 70% and 72% for the CIV-absent variable, and 83% and 91% for the heterogeneous CH-EUS-enhancement variable, respectively. CH-EUS was more accurate than standard and color Doppler EUS, except the short axis cut-off. Notably, three patients excluded because of EUS-FNA failure were correctly N-staged by CH-EUS.CONCLUSION: CH-EUS complements standard and color Doppler EUS and EUS-FNA for assessment of lymph node metastases. 展开更多
关键词 CONTRAST-ENHANCED HARMONIC endoscopic ULTRASONOGRAPHY Sensitivity and SPECIFICITY LYMPH node Pancrea
下载PDF
Endoscopic ultrasound-guided gallbladder drainage for acute cholecystitis: Long-term outcomes after removal of a self-expandable metal stent 被引量:15
3
作者 Ken Kamata Mamoru Takenaka +9 位作者 Masayuki Kitano shunsuke omoto Takeshi Miyata Kosuke Minaga Kentaro Yamao Hajime Imai Toshiharu Sakurai Tomohiro Watanabe Naoshi Nishida Masatoshi Kudo 《World Journal of Gastroenterology》 SCIE CAS 2017年第4期661-667,共7页
AIM To assess the long-term outcomes of this procedure after removal of self-expandable metal stent(SEMS). The efficacy and safety of endoscopic ultrasoundguided gallbladder drainage(EUS-GBD) with SEMS were also asses... AIM To assess the long-term outcomes of this procedure after removal of self-expandable metal stent(SEMS). The efficacy and safety of endoscopic ultrasoundguided gallbladder drainage(EUS-GBD) with SEMS were also assessed.METHODS Between January 2010 and April 2015, 12 patients with acute calculous cholecystitis, who were deemed unsuitable for cholecystectomy, underwent EUSGBD with a SEMS. EUS-GBD was performed under the guidance of EUS and fluoroscopy, by puncturing the gallbladder with a needle, inserting a guidewire, dilating the puncture hole, and placing a SEMS. TheSEMS was removed and/or replaced with a 7-Fr plastic pigtail stent after cholecystitis improved. The technical and clinical success rates, adverse event rate, and recurrence rate were all measured.RESULTS The rates of technical success, clinical success, and adverse events were 100%, 100%, and 0%, respectively. After cholecystitis improved, the SEMS was removed without replacement in eight patients, whereas it was replaced with a 7-Fr pigtail stent in four patients. Recurrence was seen in one patient(8.3%) who did not receive a replacement pigtail stent. The median follow-up period after EUS-GBD was 304 d(78-1492).CONCLUSION EUS-GBD with a SEMS is a possible alternative treatment for acute cholecystitis. Long-term outcomes after removal of the SEMS were excellent. Removal of the SEMS at 4-wk after SEMS placement and improvement of symptoms might avoid migration of the stent and recurrence of cholecystitis due to food impaction. 展开更多
关键词 内视镜的指导超声的胆囊排水 胆汁 内视镜的指导超声的胆汁的排水
下载PDF
Modified single transluminal gateway transcystic multiple drainage technique for a huge infected walled-off pancreatic necrosis: A case report 被引量:2
4
作者 Kosuke Minaga Masayuki Kitano +8 位作者 Hajime Imai Kentaro Yamao Ken Kamata Takeshi Miyata Tomohiko Matsuda shunsuke omoto Kumpei Kadosaka Tomoe Yoshikawa Masatoshi Kudo 《World Journal of Gastroenterology》 SCIE CAS 2016年第21期5132-5136,共5页
We report a successful endoscopic ultrasonographyguided drainage of a huge infected multilocular walledoff necrosis(WON) that was treated by a modified single transluminal gateway transcystic multiple drainage(SGTMD) ... We report a successful endoscopic ultrasonographyguided drainage of a huge infected multilocular walledoff necrosis(WON) that was treated by a modified single transluminal gateway transcystic multiple drainage(SGTMD) technique. After placing a widecaliber fully covered metal stent, follow-up computed tomography revealed an undrained subcavity of WON. A large fistula that was created by the wide-caliber metal stent enabled the insertion of a forward-viewing upper endoscope directly into the main cavity, and the narrow connection route within the main cavity to the subcavity was identified with a direct view, leading to the successful drainage of the subcavity. This modified SGTMD technique appears to be useful for seeking connection routes between subcavities of WON in some cases. 展开更多
关键词 ENDOSCOPIC ULTRASONOGRAPHY INFECTED pancreatic NECROSIS Walled-off NECROSIS ENDOSCOPIC ultrasonograp
下载PDF
Evaluation of anti-migration properties of biliary covered self-expandable metal stents 被引量:1
5
作者 Kosuke Minaga Masayuki Kitano +9 位作者 Hajime Imai Yogesh Harwani Kentaro Yamao Ken Kamata Takeshi Miyata shunsuke omoto Kumpei Kadosaka Toshiharu Sakurai Naoshi Nishida Masatoshi Kudo 《World Journal of Gastroenterology》 SCIE CAS 2016年第30期6917-6924,共8页
AIM: To assess anti-migration potential of six biliary covered self-expandable metal stents(C-SEMSs) by using a newly designed phantom model. METHODS: In the phantom model, the stent was placed in differently sized ho... AIM: To assess anti-migration potential of six biliary covered self-expandable metal stents(C-SEMSs) by using a newly designed phantom model. METHODS: In the phantom model, the stent was placed in differently sized holes in a silicone wall and retracted with a retraction robot. Resistance force to migration(RFM) was measured by a force gauge on the stent end. Radial force(RF) was measured with a RF measurement machine. Measured flare structure variables were the outer diameter, height, and taper angle of the flare(ODF, HF, and TAF, respectively). Correlations between RFM and RF or flare variables were analyzed using a linear correlated model.RESULTS: Out of the six stents, five stents were braided, the other was laser-cut. The RF and RFM of each stent were expressed as the average of five replicate measurements. For all six stents, RFM and RF decreased as the hole diameter increased. For all six stents, RFM and RF correlated strongly when the stent had not fully expanded. This correlation was not observed in the five braided stents excluding the laser cut stent. For all six stents, there was a strong correlation between RFM and TAF when the stent fully expanded. For the five braided stents, RFM after full stent expansion correlated strongly with all three stent flare structure variables(ODF, HF, and TAF). The laser-cut C-SEMS had higher RFMs than the braided C-SEMSs regardless of expansion state.CONCLUSION: RF was an important anti-migration property when the C-SEMS did not fully expand. Once fully expanded, stent flare structure variables plays an important role in anti-migration. 展开更多
关键词 BILIARY STRICTURE Self-expandable metal stent Radial FORCE Resistance FORCE to MIGRATION Antimigrati
下载PDF
Clinical utility of treatment method conversion during single-session endoscopic ultrasound-guided biliary drainage
6
作者 Kosuke Minaga Mamoru Takenaka +10 位作者 Kentaro Yamao Ken Kamata shunsuke omoto Atsushi Nakai Tomohiro Yamazaki Ayana Okamoto Rei Ishikawa Tomoe Yoshikawa Yasutaka Chiba Tomohiro Watanabe Masatoshi Kudo 《World Journal of Gastroenterology》 SCIE CAS 2020年第9期947-959,共13页
BACKGROUND Although several techniques for endoscopic ultrasound-guided biliary drainage(EUS-BD)are available at present,an optimal treatment algorithm of EUS-BD has not yet been established.AIM To evaluate the clinic... BACKGROUND Although several techniques for endoscopic ultrasound-guided biliary drainage(EUS-BD)are available at present,an optimal treatment algorithm of EUS-BD has not yet been established.AIM To evaluate the clinical utility of treatment method conversion during single endoscopic sessions for difficult cases in initially planned EUS-BD.METHODS This was a single-center retrospective analysis using a prospectively accumulated database.Patients with biliary obstruction undergoing EUS-BD between May 2008 and April 2016 were included.The primary outcome was to evaluate the improvement in EUS-BD success rates by converting the treatment methods during a single endoscopic session.Secondary outcomes were clarification of the factors leading to the conversion from the initial EUS-BD and the assessment of efficacy and safety of the conversion as judged by technical success,clinical success,and adverse events(AEs).RESULTS A total of 208 patients underwent EUS-BD during the study period.For 18.8%(39/208)of the patients,the treatment methods were converted to another EUSBD technique from the initial plan.Biliary obstruction was caused by pancreatobiliary malignancies,other malignant lesions,biliary stones,and other benign lesions in 22,11,4,and 2 patients,respectively.The reasons for the difficulty with the initial EUS-BD were classified into the following 3 procedures:Target puncture(n=13),guidewire manipulation(n=18),and puncture tract dilation(n=8).Technical success was achieved in 97.4%(38/39)of the cases and clinical success was achieved in 89.5%of patients(34/38).AEs occurred in 10.3%of patients,including bile leakage(n=2),bleeding(n=1),and cholecystitis(n=1).The puncture target and drainage technique were altered in subsequent EUSBD procedures in 25 and 14 patients,respectively.The final technical success rate with 95%CI for all 208 cases was 97.1%(95%CI:93.8%-98.9%),while that of the initially planned EUS-BD was 78.8%(95%CI:72.6%-84.2%).CONCLUSION Among multi-step procedures in EUS-BD,guidewire manipulation appeared to be the most technically challenging.When initially planned EUS-BD is technically difficult,treatment method conversion in a single endoscopic session may result in successful EUS-BD without leading to severe AEs. 展开更多
关键词 Endoscopic ultrasound Endoscopic ultrasound-guided biliary drainage Interventional endoscopic ultrasound Biliary drainage Biliary obstruction
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部