Saltwater intrusion caused by groundwater over-exploitation from coastal aquifers poses a severe problem in many regions. The Fum Al Wad aquifer is located between Atlantic Ocean in the West and Laayoun in the East. T...Saltwater intrusion caused by groundwater over-exploitation from coastal aquifers poses a severe problem in many regions. The Fum Al Wad aquifer is located between Atlantic Ocean in the West and Laayoun in the East. This aquifer covers an area of 250 Km2, and represents an essential water resource for Laayoun city and the periphery regions. It is heavily exploited for water supply, agriculture and industry. The freshwater-saltwater interface is affected by groundwater extraction by public supplies, irrigation wells, and domestic wells in the coastal of this aquifer. The position of the interface is controlled by several factors: these include precipitation, recharge rate, dryness, evapotranspiration, hydraulic conductivity and hydraulic head. Landward migration of the interface freshwater-saltwater often results in a significant decrease in the water resources available for coastal communities. The volume pumped by public for irrigation and the domestic usage in 2010-2011 is estimated 2.5 Mm3/year, and in 2015 about 2.91 Mm3/year only for domestic usages. The objectives of this work are to model the groundwater flow and saltwater intrusion in the coastal aquifer of Fum Al Wad, by SEAWAT-2000 program which coupled both the version of MODFLOW-2000 and MT3DMS. They are designed to simulate variable-density groundwater flow and solute transport in three dimensions. The model is calibrated for hydraulic conductivity, specific yield, porosity, and recharge rate as well as dispersivity coefficient. The result of simulation of the hydrodynamic model during the period of 1986-2015 has revealed a piezometric drawdown with 2.3 m approximately at the level of the pumping zone. Furthermore, this piezometric depression is caused by excessive pumping of the various uses of water and its corresponding that has resulted in the migration of the saltwater intrusion into freshwater with 4.3 km approximately. The simulations result for scenarios 2020 and 2030 of Fum Al Wad aquifer showed a vertical decrease of the piezometric head (about 2.5 m) in 2030, but the saltwater intrusion has advanced diagonally to reach 4.7 km under the freshwater of groundwater of this aquifer.展开更多
Laayoune and the Foum El Oued aquifers are in hydraulic communication only at the level of Oued Saguia El Hamra. The present study has accordingly made use of all the hydrogeological, hydrological, geological and geop...Laayoune and the Foum El Oued aquifers are in hydraulic communication only at the level of Oued Saguia El Hamra. The present study has accordingly made use of all the hydrogeological, hydrological, geological and geophysical data that preceded the watershed of Oued Saguia El Hamra in its downstream part. These data are by no means omplementary with the objective of having a better understanding of the boundary line between Laayoune and Foum El Oued aquifers and the origin of feeding the sources of Oued Saguia El Hamra. This study will focus only on the previous geophysical studies where a reinterpretation of electrical soundings has proved useful as a result of the recent well-logging results. It makes it possible to highlight the presence of a significant rise in the truncated marly substratum of Oued Saguia El Hamra and depressions (left and right banks) which could correspond to stream channels or depressed areas. At the level of the Wadi bed, there has been a regular immersion of the conductive level roofs from east to west towards Foum El Oued favoring the flow of wastewater from the zone and spraying the brackish water sources towards the groundwater of Foum El Oued. In the light of the reinterpretation of electric polls, plus as well as the geophysical surveys by electrical tomography and high definition made at the right and left banks of the Oueed Saguia El-Hamra, it was possible to verify the existence of dry ridge separating the two webs of Laayoune and Foum El Oued and stream channels or depressed areas of the left bank for drainage of brackish water to sources located along Oued Saguia El Hamra. The true resistivity models tomography profiles confirm the presence of the backbone at the left and right banks and the graben of the left bank for underground water drainage of the web Laayoune to sources welling the river Saguia El Hamra. They reveal the presence of a quaternary plio-cover (coastal platform Moghrebian) as being heterogeneous and affected by many electrical discontinuities, particularly in the level resistant R2 (coquina sandstone). These discontinuities could correspond to lateral changes in facies and/or synsedimental faults compartmentalizing the plio-quaternary formations into a system of Horsts and Grabens that relies on the whole (D1, Cs) attributed to formations from the Miocene to the Upper Cretaceous. The contours of the map show the distribution of the three families of electrical soundings A, B and C limited by two main electrical discontinuities D and M. East of discontinuity million, this map reflects the look of the wall of the Pliocene-Quaternary resting on the impermeable upper Cretaceous floor. To the west of this electrical discontinuity M, the map reflects the behavior of the roof of marl deposits of Miocene age.展开更多
The Tartar aquifer unit, is located at the SSO of the city of Boujdour, at a distance of nearly 86 km, and crossed (in its western part) by the National Road N1 connecting the towns of Boujdour and Lagouira passing th...The Tartar aquifer unit, is located at the SSO of the city of Boujdour, at a distance of nearly 86 km, and crossed (in its western part) by the National Road N1 connecting the towns of Boujdour and Lagouira passing through the vicinity of the city of Dakhla (PK40). It is exploited by rural settlements for domestic use (especially the inhabitants of fishing villages) and livestock watering, only through wells named Khtout Hobia (IRE 126/124) and Hassi Tartar known as Khtout Trayh (IRE 104/124). These wells have been tracked by a piezometric groundwater table and from 2011 to the present day. The interpretation of the electrical soundings in AB ≤ 2000 m allowed to differentiate the presence of two families of electrical soundings A and B, to establish the resistivity maps in AB = 200, 300 and 400 ihm⋅m with qualitative aspects, to draw up the map of the isohypses of the roof of the intermediate Dt1 representing the impermeable floor of the aquifer and to highlight two types of discontinuities;electrical discontinuities corresponding to lateral facies changes (limit of erosion surfaces) separating the families A and B of electrical soundings and those corresponding to syn-sedimentary faults which structured the formations into horsts and grabens. The lithological sections of the existing water points and that of oil well 43-1 allowed the geological identification of the geoelectric layers highlighted by the electrical soundings diagrams. As a result, the sandstone and lumachelic formations constituting the aquifer are of Moghrebian-Pleistocene age represented by the resistant R (Family A), sometimes grouping, in its basal part, sandstone levels of the Miocene roof (Family B). These formations lie directly on the Miocene sandy marls represented by the intermediate Dt1. For the present work, we will focus only on the transverse geoelectric cross-section TA, with an SW-NE orientation, which characterizes all the longitudinal sections established following the correlation between the different electric sounding diagrams. It highlights the presence of the gravels G1 and G3 separated by the horst H1 where the resistant R is admitted as aquiferous at the level of the gravels G1 (Khtout Trayh well 104/124) and G3 (well 126/124) and sterile at the level of the horst H1.展开更多
文摘Saltwater intrusion caused by groundwater over-exploitation from coastal aquifers poses a severe problem in many regions. The Fum Al Wad aquifer is located between Atlantic Ocean in the West and Laayoun in the East. This aquifer covers an area of 250 Km2, and represents an essential water resource for Laayoun city and the periphery regions. It is heavily exploited for water supply, agriculture and industry. The freshwater-saltwater interface is affected by groundwater extraction by public supplies, irrigation wells, and domestic wells in the coastal of this aquifer. The position of the interface is controlled by several factors: these include precipitation, recharge rate, dryness, evapotranspiration, hydraulic conductivity and hydraulic head. Landward migration of the interface freshwater-saltwater often results in a significant decrease in the water resources available for coastal communities. The volume pumped by public for irrigation and the domestic usage in 2010-2011 is estimated 2.5 Mm3/year, and in 2015 about 2.91 Mm3/year only for domestic usages. The objectives of this work are to model the groundwater flow and saltwater intrusion in the coastal aquifer of Fum Al Wad, by SEAWAT-2000 program which coupled both the version of MODFLOW-2000 and MT3DMS. They are designed to simulate variable-density groundwater flow and solute transport in three dimensions. The model is calibrated for hydraulic conductivity, specific yield, porosity, and recharge rate as well as dispersivity coefficient. The result of simulation of the hydrodynamic model during the period of 1986-2015 has revealed a piezometric drawdown with 2.3 m approximately at the level of the pumping zone. Furthermore, this piezometric depression is caused by excessive pumping of the various uses of water and its corresponding that has resulted in the migration of the saltwater intrusion into freshwater with 4.3 km approximately. The simulations result for scenarios 2020 and 2030 of Fum Al Wad aquifer showed a vertical decrease of the piezometric head (about 2.5 m) in 2030, but the saltwater intrusion has advanced diagonally to reach 4.7 km under the freshwater of groundwater of this aquifer.
文摘Laayoune and the Foum El Oued aquifers are in hydraulic communication only at the level of Oued Saguia El Hamra. The present study has accordingly made use of all the hydrogeological, hydrological, geological and geophysical data that preceded the watershed of Oued Saguia El Hamra in its downstream part. These data are by no means omplementary with the objective of having a better understanding of the boundary line between Laayoune and Foum El Oued aquifers and the origin of feeding the sources of Oued Saguia El Hamra. This study will focus only on the previous geophysical studies where a reinterpretation of electrical soundings has proved useful as a result of the recent well-logging results. It makes it possible to highlight the presence of a significant rise in the truncated marly substratum of Oued Saguia El Hamra and depressions (left and right banks) which could correspond to stream channels or depressed areas. At the level of the Wadi bed, there has been a regular immersion of the conductive level roofs from east to west towards Foum El Oued favoring the flow of wastewater from the zone and spraying the brackish water sources towards the groundwater of Foum El Oued. In the light of the reinterpretation of electric polls, plus as well as the geophysical surveys by electrical tomography and high definition made at the right and left banks of the Oueed Saguia El-Hamra, it was possible to verify the existence of dry ridge separating the two webs of Laayoune and Foum El Oued and stream channels or depressed areas of the left bank for drainage of brackish water to sources located along Oued Saguia El Hamra. The true resistivity models tomography profiles confirm the presence of the backbone at the left and right banks and the graben of the left bank for underground water drainage of the web Laayoune to sources welling the river Saguia El Hamra. They reveal the presence of a quaternary plio-cover (coastal platform Moghrebian) as being heterogeneous and affected by many electrical discontinuities, particularly in the level resistant R2 (coquina sandstone). These discontinuities could correspond to lateral changes in facies and/or synsedimental faults compartmentalizing the plio-quaternary formations into a system of Horsts and Grabens that relies on the whole (D1, Cs) attributed to formations from the Miocene to the Upper Cretaceous. The contours of the map show the distribution of the three families of electrical soundings A, B and C limited by two main electrical discontinuities D and M. East of discontinuity million, this map reflects the look of the wall of the Pliocene-Quaternary resting on the impermeable upper Cretaceous floor. To the west of this electrical discontinuity M, the map reflects the behavior of the roof of marl deposits of Miocene age.
文摘The Tartar aquifer unit, is located at the SSO of the city of Boujdour, at a distance of nearly 86 km, and crossed (in its western part) by the National Road N1 connecting the towns of Boujdour and Lagouira passing through the vicinity of the city of Dakhla (PK40). It is exploited by rural settlements for domestic use (especially the inhabitants of fishing villages) and livestock watering, only through wells named Khtout Hobia (IRE 126/124) and Hassi Tartar known as Khtout Trayh (IRE 104/124). These wells have been tracked by a piezometric groundwater table and from 2011 to the present day. The interpretation of the electrical soundings in AB ≤ 2000 m allowed to differentiate the presence of two families of electrical soundings A and B, to establish the resistivity maps in AB = 200, 300 and 400 ihm⋅m with qualitative aspects, to draw up the map of the isohypses of the roof of the intermediate Dt1 representing the impermeable floor of the aquifer and to highlight two types of discontinuities;electrical discontinuities corresponding to lateral facies changes (limit of erosion surfaces) separating the families A and B of electrical soundings and those corresponding to syn-sedimentary faults which structured the formations into horsts and grabens. The lithological sections of the existing water points and that of oil well 43-1 allowed the geological identification of the geoelectric layers highlighted by the electrical soundings diagrams. As a result, the sandstone and lumachelic formations constituting the aquifer are of Moghrebian-Pleistocene age represented by the resistant R (Family A), sometimes grouping, in its basal part, sandstone levels of the Miocene roof (Family B). These formations lie directly on the Miocene sandy marls represented by the intermediate Dt1. For the present work, we will focus only on the transverse geoelectric cross-section TA, with an SW-NE orientation, which characterizes all the longitudinal sections established following the correlation between the different electric sounding diagrams. It highlights the presence of the gravels G1 and G3 separated by the horst H1 where the resistant R is admitted as aquiferous at the level of the gravels G1 (Khtout Trayh well 104/124) and G3 (well 126/124) and sterile at the level of the horst H1.