Purpose To evaluate the prompt and induced dose rate in backscattering neutron hall for radiation protection and safety management.Method The dose rates were calculated by Monte Carlo code FLUKA,with the"multi-st...Purpose To evaluate the prompt and induced dose rate in backscattering neutron hall for radiation protection and safety management.Method The dose rates were calculated by Monte Carlo code FLUKA,with the"multi-step"simulation method based on traditional"two-step simulation"method.Conclusion Operation time of staff workers does not need to be restricted.But with the increase in beam power and irra-diation time,serious consideration might need to be taken as the dose rate of samples may be higher than the limit value.展开更多
基金supported by the National Key Research and Development Program of China(Project:2016YFA0401601)
文摘Purpose To evaluate the prompt and induced dose rate in backscattering neutron hall for radiation protection and safety management.Method The dose rates were calculated by Monte Carlo code FLUKA,with the"multi-step"simulation method based on traditional"two-step simulation"method.Conclusion Operation time of staff workers does not need to be restricted.But with the increase in beam power and irra-diation time,serious consideration might need to be taken as the dose rate of samples may be higher than the limit value.