This study proposes a hypodermic needle(HN)as a sorbent holder and an electrospray(ESI)emitter,thus combining extraction and analysis in a single device.A novel nylon 6-cellulose(N6-Cel)composite sorbent is proposed t...This study proposes a hypodermic needle(HN)as a sorbent holder and an electrospray(ESI)emitter,thus combining extraction and analysis in a single device.A novel nylon 6-cellulose(N6-Cel)composite sorbent is proposed to extract methadone from oral fluid samples.The cellulosic substrate provides the composite with high porosity,permitting the flow-through of the sample,while the polyamide contributes to the extraction of the analyte.The low price of the devices(considering the holder and the sorbent)contributes to the affordability of the method,and their small size allows easy transportation,opening the door to on-site extractions.Under the optimum conditions,the analyte can be determined by high-resolution ambient ionization mass spectrometry at a limit of detection(LOD)as low as 0.3 mg/L and precision(expressed as relative standard deviation,RSD)better than 9.3%.The trueness,expressed as relative recovery(RR),ranged from 90%to 109%.As high-resolution mass spectrometers are not available in many laboratories,the method was also adapted to low-resolution spectrometers.In this sense,the direct infusion of the eluates in a triple quadrupole-mass spectrometry provided an LOD of 2.2 mg/L.The RSD was better than 5.3%,and the RR ranged from 96%to 121%.展开更多
基金The grant“Biopolymer substrates for the determination of opioids in biofluids by ambient mass spectrometry”(Grant No.:PID2020-112862RB-I00)funded by MCIN/AEI/10.13039/501100011033(Feder“Una manera de hacer Europa”)is gratefully acknowledged。
文摘This study proposes a hypodermic needle(HN)as a sorbent holder and an electrospray(ESI)emitter,thus combining extraction and analysis in a single device.A novel nylon 6-cellulose(N6-Cel)composite sorbent is proposed to extract methadone from oral fluid samples.The cellulosic substrate provides the composite with high porosity,permitting the flow-through of the sample,while the polyamide contributes to the extraction of the analyte.The low price of the devices(considering the holder and the sorbent)contributes to the affordability of the method,and their small size allows easy transportation,opening the door to on-site extractions.Under the optimum conditions,the analyte can be determined by high-resolution ambient ionization mass spectrometry at a limit of detection(LOD)as low as 0.3 mg/L and precision(expressed as relative standard deviation,RSD)better than 9.3%.The trueness,expressed as relative recovery(RR),ranged from 90%to 109%.As high-resolution mass spectrometers are not available in many laboratories,the method was also adapted to low-resolution spectrometers.In this sense,the direct infusion of the eluates in a triple quadrupole-mass spectrometry provided an LOD of 2.2 mg/L.The RSD was better than 5.3%,and the RR ranged from 96%to 121%.