Exhaled ammonia(NH_(3))is an essential noninvasive biomarker for disease diagnosis.In this study,an acetone-modifier positive photoionization ion mobility spectrometry(AM-PIMS)method was developed for accurate qualita...Exhaled ammonia(NH_(3))is an essential noninvasive biomarker for disease diagnosis.In this study,an acetone-modifier positive photoionization ion mobility spectrometry(AM-PIMS)method was developed for accurate qualitative and quantitative analysis of exhaled NH_(3)with high selectivity and sensitivity.Acetone was introduced into the drift tube along with the drift gas as a modifier,and the characteristic NH_(3)product ion peak of(C_(3)H_(6)O)_(4)NH_(4)^(+)(K_(0)=1.45 cm^(2)/V·s)was obtained through the ion-molecule reaction with acetone reactant ions(C_(3)H_(6)O)_(2)H^(+)(K_(0)=1.87 cm^(2)/V·s),which significantly increased the peak-to-peak resolution and improved the accuracy of exhaled NH_(3)qualitative identification.Moreover,the interference of high humidity and the memory effect of NH_(3)molecules were significantly reduced via online dilution and purging sampling,thus realizing breath-by-breath measurement.As a result,a wide quantitative range of 5.87-140.92μmol/L with a response time of 40 ms was achieved,and the exhaled NH_(3)profile could be synchronized with the concentration curve of exhaled CO_(2).Finally,the analytical capacity of AM-PIMS was demonstrated by measuring the exhaled NH_(3)of healthy subjects,demonstrating its great potential for clinical disease diagnosis.展开更多
基金This work was supported by the National Natural Science Foundation of China(Grant Nos.:22027804,21974141,and 21904125)Natural Science Foundation of Liaoning Province(Grant Nos.:2022-MS-019 and 2022-MS-016)+2 种基金Science and Technology Innovation Foundation of Dalian(Grant No.:2022JJ13SN096)Dalian Institute of Chemical Physics(Grant Nos.:DICP I202141 and DICP I202144)1+X Program for Large Cohort Study-Clinical Research Incubation Project,The Second Hospital of Dalian Medical University(Project No.:2022DXDL01).
文摘Exhaled ammonia(NH_(3))is an essential noninvasive biomarker for disease diagnosis.In this study,an acetone-modifier positive photoionization ion mobility spectrometry(AM-PIMS)method was developed for accurate qualitative and quantitative analysis of exhaled NH_(3)with high selectivity and sensitivity.Acetone was introduced into the drift tube along with the drift gas as a modifier,and the characteristic NH_(3)product ion peak of(C_(3)H_(6)O)_(4)NH_(4)^(+)(K_(0)=1.45 cm^(2)/V·s)was obtained through the ion-molecule reaction with acetone reactant ions(C_(3)H_(6)O)_(2)H^(+)(K_(0)=1.87 cm^(2)/V·s),which significantly increased the peak-to-peak resolution and improved the accuracy of exhaled NH_(3)qualitative identification.Moreover,the interference of high humidity and the memory effect of NH_(3)molecules were significantly reduced via online dilution and purging sampling,thus realizing breath-by-breath measurement.As a result,a wide quantitative range of 5.87-140.92μmol/L with a response time of 40 ms was achieved,and the exhaled NH_(3)profile could be synchronized with the concentration curve of exhaled CO_(2).Finally,the analytical capacity of AM-PIMS was demonstrated by measuring the exhaled NH_(3)of healthy subjects,demonstrating its great potential for clinical disease diagnosis.