期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Safety and Efficacy of a Novel Everolimus-Eluting Stent System in “Real-World” Patients with Coronary Artery Disease: A Report of Preliminary Outcomes
1
作者 Sridhar Kasturi srinivas polasa +6 位作者 Shailender Singh Vijay Kumar Reddy Kondal Rao Ganesh Mathan Shiva Kumar Bandimida Manikandhar Pendyala Chandrashekar Challa 《World Journal of Cardiovascular Diseases》 2016年第12期458-467,共11页
Introduction: Tetrilimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) is a recently-introduced biodegradable-polymer coated everolimus-eluting cobalt-chromium coronary stent system with an ultra-thin stru... Introduction: Tetrilimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) is a recently-introduced biodegradable-polymer coated everolimus-eluting cobalt-chromium coronary stent system with an ultra-thin strut thickness. We aimed to evaluate the clinical outcomes with Tetrilimus coronary stents in “real-world” patients with coronary artery disease. Methods: In this retrospective, single-arm, open-label, multi-center registry, all consecutive patients who received Tetrilimus stents between July-2015 and April-2016 at two tertiary-care centers in India were analyzed. Primary endpoint was 30-day incidence of major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction, target lesion revascularization, and target vessel revascularization. The Academic Research Consortium (ARC)-defined stent thrombosis was assessed as additional safety endpoint. Results: During the study period, 280 Tetrilimus stents (1.4 ± 0.5 stent/patient) were implanted to treat 252 coronary lesions (1.1 ± 0.3 stent/lesion) in 208 patients (age: 57.5 ± 11.9 years). Of study population, 65.9% were males, 46.6% were hypertensives, 25% were diabetics, 36.5% were alcoholics, 29.3% were smokers, 13.9% were tobacco chewers, 5.3% had previous revascularization, and 45.2% displayed multi-vessel disease. Of treated lesions, 67.5% were complex and 18.7% had total occlusion. Average length and diameter of implanted stents were 25.5 ± 8.8 mm and 2.9 ± 0.3 mm respectively. Subsequently, 30-day MACE were reported in 2 (0.96%) patients;both cases owing to in-hospital cardiac deaths. Events of stent thrombosis or noncardiac death were not reported in any patient. Conclusion: Low MACE rates and absence of stent thrombosis at early 30-day follow-up indicates that Tetrilimus everolimus-eluting stents may have encouraging safety and efficacy in unselected “real-world” patients with coronary artery disease. 展开更多
关键词 Biodegradable Polymer Percutaneous Coronary Intervention Everolimus-Eluting
下载PDF
A Real World Experience of Guidewire-Induced Perforations during Percutaneous Intervention and Their Successful Management
2
作者 Sridhar Kasturi Vinothkumar Vilvanathan +3 位作者 srinivas polasa Shiva Kumar Bandimida Kripa Patel Ashok Thakkar 《International Journal of Clinical Medicine》 2014年第8期475-481,共7页
Complication rates following percutaneous interventions have decreased over the past decade due to advancement in both interventional equipment and procedure technique. Despite these advances, the risk of iatrogenic p... Complication rates following percutaneous interventions have decreased over the past decade due to advancement in both interventional equipment and procedure technique. Despite these advances, the risk of iatrogenic perforations still exists with associated high morbidity and mortality. We are presenting three cases of guidewire-induced perforations including coronary artery and renal artery perforation with their complications and successful management in these case-series. 展开更多
关键词 PERCUTANEOUS Intervention GUIDEWIRE CORONARY ARTERY PERFORATION Renal ARTERY PERFORATION
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部