期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Transcatheter Ventricular Septal Defect Closure with Nit-Occlud LêVSD Device—Five Years’Experience and Literature Review
1
作者 Ivana B.Cerović Vladislav A.Vukomanović +6 位作者 Jovan Lj.Košutić Mila S.stajević Sanja S.Ninić Saša S.Popović Ivan d.d.zd.rević staša d.krasić Sergej M.Prijić 《Congenital Heart Disease》 SCIE 2023年第3期361-371,共11页
Introduction:Transcatheter closure is an alternative to ventricular septal defect(VSD)occlusion surgery.Nit-Occlud LêVSD coil is a new device yet to be evaluated.The study aimed to evaluate immediate and midterm ... Introduction:Transcatheter closure is an alternative to ventricular septal defect(VSD)occlusion surgery.Nit-Occlud LêVSD coil is a new device yet to be evaluated.The study aimed to evaluate immediate and midterm results after transcatheter closure with the Nit-Occlud LêVSD device.Methods:The retrospective analysis included 30 patients with VSD referred for closure during the period from October 2015 to December 2020.Results:At the time of intervention,the patients’mean age and body weights were 7.5±5.6 years and 29.3±19.1 kg.The majority of the defects had perimembranous location(24/30),four defects had muscular and two outlet subaortic position.The mean effective right-side diameter of the VSDs was 3.6±1.3 mm.Single ventricular fibrillation,device embolization,and hemolysis developed in different patients and were successfully treated.None of the patients had a complete atrioventricular block.The coil was successfully placed in 25/30(83.3%)patients.The majority of the devices were 10 mm×6 mm(11/25)and 12 mm×8 mm(8/25)in size.Two patients required the implantation of a second device.The follow-up period was 2.1±1.4 years.Complete VSD closure was achieved in 48%of cases immediately after the intervention,74%during 2.1±1.6 months after the procedure,and 81%over follow-up.The remaining patients had a trivial residual defect.During the follow-up,approximately one-third of patients developed trivial aortic and mitral valve regurgitation,and half of the patients acquired trace/mild tricuspid regurgitation.Standardized(z-score)left ventricular end-diastolic diameter(0.15±0.37 vs.0.92±0.82,p=0.005)and left atrium dimension(0.47±0.58 vs.1.89±1.11,p=0.005),as well as the left atrium to aortic root ratio(1.2±0.1 vs.1.4±0.2,p=0.005)showed a significant decrease over follow-up related to the period before intervention.Conclusion:Intervention with Nit-OccludLêVSD coil showed appropriate results regarding VSD closure rate,complications,and chamber remodeling.The introduction of this device into clinical practice is a significant step forward in transcatheter perimembranous VSD occlusion. 展开更多
关键词 Ventricular septal defect TRANSCATHETER DEVICE children
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部