期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Manifestations of type 2 diabetes in corneal endothelial cell density,corneal thickness and intraocular pressure 被引量:1
1
作者 stella briggs Uchechukwu L Osuagwu Essam M AlHarthi 《The Journal of Biomedical Research》 CAS CSCD 2016年第1期46-51,共6页
We sought to evaluate central corneal thickness(CCT),corneal endothelial cell density(ECD)and intraocular pressure(IOP)in patients with type 2 diabetes mellitus(DM)and to associate potential differences with d... We sought to evaluate central corneal thickness(CCT),corneal endothelial cell density(ECD)and intraocular pressure(IOP)in patients with type 2 diabetes mellitus(DM)and to associate potential differences with diabetes duration and treatment modality in a prospective,randomized study.We measured ECD,CCT and IOP of125 patients with type 2 DM(mean age 57.1±11.5 years)and compared them with 90 age-matched controls.Measured parameters were analyzed for association with diabetes duration and glucose control modalities(insulin injection or oral medication)while controlling for age.In the diabetic group,the mean ECD(2511±252 cells/mm^2),mean CCT(539.7±33.6μm)and mean IOP(18.3±2.5 mmHg)varied significantly from those the control group[ECD:2713±132 cells/mm^2(P〈0.0001),CCT:525.0±45.3μm(P=0.003)and IOP:16.7±1.8 mmHg(P〈0.0001)].ECD was significantly reduced by about 32 cell/mm^2 for diabetics with duration of〉10 years when compared with those with duration of〈10 years(P〈0.05).CCT was thicker and IOP was higher for diabetics with duration of〉10 years than those with duration of〈10 years(P〉0.05).None of the measured parameters was significantly associated with diabetes duration and treatment modality(P〉0.05).In conclusion,subjects with type 2DM exhibit significant changes in ECD,IOP and CCT,which,however,are not correlated with disease duration or if the patients receive on insulin injection or oral medications. 展开更多
关键词 type 2 diabetes corneal endothelial cells central corneal thickness diabetes duration and control
下载PDF
Effect of 2% fluorescein on Scheimpflug central corneal thickness measurements
2
作者 stella briggs Marwa Bin Moammar 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第2期239-242,共4页
AIM: To assess central corneal thickness (CCT) changes measured with Scheimpflug device following instillation of 2% fluorescein in normal subjects. ~ METHODS: This was a prospective randomized study of 60 hospita... AIM: To assess central corneal thickness (CCT) changes measured with Scheimpflug device following instillation of 2% fluorescein in normal subjects. ~ METHODS: This was a prospective randomized study of 60 hospital volunteers. After baseline CCT measurements of both eyes of 40 subjects were obtained using Scheimpflug system, a drop of preservative-free 2% fluorescein, was instilled in one eye and in other eye, one drop of normal saline (control). Measurements were repeated after 1, 2, 5, 10, 20, 30, 40, 50 and 60min (continuous assessment group). Twenty subjects had baseline CCT taken, then fluorescein was instilled in one eye and measurements were taken at lmin. Ten eyes had saline rinse after lmin and 10 other eyes did not, measurements were repeated at 2min (eye rinse group). RESULTS: The mean baseline CCT for continuous assessment group was 546.2±32.1um (range, 489.0-606.0), control eyes was 546.6~±30.7 um (range, 489.0-602.0). At lmin after fluorescein instillation, CCT significantly increased by 37.0±34.0um (P〈0.001), then decreased gradually, reaching baseline at 60min. CCT variations were not significant in control group (P〉0.05). For eye rinse group, CCT mean differences between baseline and 2min were 18.2um (95 % Ch -54.7 to 18.3) with rinse and 26.5um (95% CI: -62.9 to 9.9) without rinse; paired sample tests were not significant (P〉0.05). CONCLUSION: The presence of fluorescein increased CCT value to a clinically relevant level of 6.8%. Eye rinse did not significantly reduce the effect at 2min post fluorescein timepoint. 展开更多
关键词 central corneal thickness FLUORESCEIN Scheimpflug device
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部