This study investigates the breakdown voltage characteristics in sulfur hexafluoride(SF6)circuit breakers,employing a novel approach that integrates both experimental investigations and finite element simulations.Util...This study investigates the breakdown voltage characteristics in sulfur hexafluoride(SF6)circuit breakers,employing a novel approach that integrates both experimental investigations and finite element simulations.Utilizing a sphere-sphere electrode configuration,we meticulously measured the relationship between breakdown voltage and electrode gap distances ranging from 1 cm to 4.5 cm.Subsequent simulations,conducted using COMSOL Multiphysics,mirrored the experimental setup to validate the model’s accuracy through a comparison of the breakdown voltage-electrode gap distance curves.The simulation results not only aligned closely with the experimental data but also allowed the extraction of detailed electric field strength,electric potential contours,and electric current flow curves at the breakdown voltage for gap distances extending from 1 to 4.5 cm.Extending the analysis,the study explored the electric field and potential distribution at a constant voltage of 72.5 kV for gap distances between 1 to 10 cm,identifying the maximum electric field strength.A comprehensive comparison of five different electrode configurations(sphere-sphere,sphere-rod,sphere-plane,rod-plane,rod-rod)at 72.5 kV and a gap distance of 1.84 cm underscored the significant influence of electrode geometry on the breakdown process.Moreover,the research contrasts the breakdown voltage in SF6 with that in air,emphasizing SF6’s superior insulating properties.This investigation not only elucidates the intricate dynamics of electrical breakdown in SF6 circuit breakers but also contributes valuable insights into the optimal electrode configurations and the potential for alternative insulating gases,steering future advancements in high-voltage circuit breaker technology.展开更多
Incomplete data accompanies our life processes and covers almost all fields of scientific studies, as a result of delivery failure, no power of battery, accidental loss, etc. However, how to model, index, and query in...Incomplete data accompanies our life processes and covers almost all fields of scientific studies, as a result of delivery failure, no power of battery, accidental loss, etc. However, how to model, index, and query incomplete data in- curs big challenges. For example, the queries struggling with incomplete data usually have dissatisfying query results due to the improper incompleteness handling methods. In this pa- per, we systematically review the management of incomplete data, including modelling, indexing, querying, and handling methods in terms of incomplete data. We also overview sev- eral application scenarios of incomplete data, and summa- rize the existing systems related to incomplete data. It is our hope that this survey could provide insights to the database community on how incomplete data is managed, and inspire database researchers to develop more advanced processing techniques and tools to cope with the issues resulting from incomplete data in the real world.展开更多
More and more attention has been paid to the high penetration of renewable energy in recent years.The randomness and intermittency of solar and wind energy make it an inevitable trend that renewables are coupled with ...More and more attention has been paid to the high penetration of renewable energy in recent years.The randomness and intermittency of solar and wind energy make it an inevitable trend that renewables are coupled with energy storage technologies.Pumped hydro storage(PHS)is the most widelyused storage form in the power grid but the capacity is limited by geographic conditions.The concentrated solar power(CSP)plant with a thermal energy storage(TES)system can realize easier grid connections and effective peak shaving.Therefore,this paper proposes a solar-wind-hydro hybrid power system with PHS-TES double energy storages,and investigates the optimal coordinated operational strategy and multi-objective sizing.The optimal sizing problem which considers the minimum levelized cost of energy(LCOE)and loss of power supply probability(LPSP)as objectives is solved by multi-objective particle swarm optimization.Moreover,the seasonal uncertainties of renewables are considered by applying a scenario-based analysis using Kmeans clustering.Finally,a case study reveals the effectiveness of the coordinated operational strategy and double energy storages from the perspectives of economy and reliability.The comparisons of optimal sizing results show that the PV-WindCSP-PHS system decreases the LCOE by 19.1%compared to a PV-Wind-CSP system under the same LPSP,and reduces the LPSP compared to PV-Wind-PHS systems with limited reservoir capacity,which indicates that the proposed system with double energy storages has better economy and reliability performance compared to single storage.展开更多
In this study, ion mobility separation coupled with tandem mass spectrometry (IM-tandem MS) was utilized to investigate the ionization behaviors of two amino acids including leucine and isoleucine. Under the electro...In this study, ion mobility separation coupled with tandem mass spectrometry (IM-tandem MS) was utilized to investigate the ionization behaviors of two amino acids including leucine and isoleucine. Under the electrospray ionization (ESI) mode, two protonation sites in each molecular sturcture caused two forms of protomer. One arose from the amino being protonated (amino-protomer) and the other from the carboxyl being protonated (car- boxyl-protomer). In the two-dimensional (drift time, m/z) spectrum, the protomers had the same mass, but the dis- tinguishable drift times and fragmentation patterns. For the characterization purpose, the theoretical collision cross section (CCS) values of the protomers were calculated and proven to be consistent with the experimental. Moreover, the quantified relationship between the amino acids and their protomers was evaluated. It showed that the abun- dance of the carboxyl-protomer was proportional to the concentration of the amino acid, whereas that of the amino- protomer did not have the same trend. Under the atmospheric pressure chemical ionization (APCI) mode, only the carboxyl-protomer was observed. In addition, the amino-protomer and the cluster ions observed under ESI were absent completely. The results demonstrate that the ionization mode impacts heavily on the ionization behaviors of leucine and isoleucine not only on the form of therir protomers but also On the quantified relationship.展开更多
基金Ningbo Science and Technology Plan Project(Grant No.2023Z043)。
文摘This study investigates the breakdown voltage characteristics in sulfur hexafluoride(SF6)circuit breakers,employing a novel approach that integrates both experimental investigations and finite element simulations.Utilizing a sphere-sphere electrode configuration,we meticulously measured the relationship between breakdown voltage and electrode gap distances ranging from 1 cm to 4.5 cm.Subsequent simulations,conducted using COMSOL Multiphysics,mirrored the experimental setup to validate the model’s accuracy through a comparison of the breakdown voltage-electrode gap distance curves.The simulation results not only aligned closely with the experimental data but also allowed the extraction of detailed electric field strength,electric potential contours,and electric current flow curves at the breakdown voltage for gap distances extending from 1 to 4.5 cm.Extending the analysis,the study explored the electric field and potential distribution at a constant voltage of 72.5 kV for gap distances between 1 to 10 cm,identifying the maximum electric field strength.A comprehensive comparison of five different electrode configurations(sphere-sphere,sphere-rod,sphere-plane,rod-plane,rod-rod)at 72.5 kV and a gap distance of 1.84 cm underscored the significant influence of electrode geometry on the breakdown process.Moreover,the research contrasts the breakdown voltage in SF6 with that in air,emphasizing SF6’s superior insulating properties.This investigation not only elucidates the intricate dynamics of electrical breakdown in SF6 circuit breakers but also contributes valuable insights into the optimal electrode configurations and the potential for alternative insulating gases,steering future advancements in high-voltage circuit breaker technology.
文摘Incomplete data accompanies our life processes and covers almost all fields of scientific studies, as a result of delivery failure, no power of battery, accidental loss, etc. However, how to model, index, and query incomplete data in- curs big challenges. For example, the queries struggling with incomplete data usually have dissatisfying query results due to the improper incompleteness handling methods. In this pa- per, we systematically review the management of incomplete data, including modelling, indexing, querying, and handling methods in terms of incomplete data. We also overview sev- eral application scenarios of incomplete data, and summa- rize the existing systems related to incomplete data. It is our hope that this survey could provide insights to the database community on how incomplete data is managed, and inspire database researchers to develop more advanced processing techniques and tools to cope with the issues resulting from incomplete data in the real world.
基金the National Key Research and Development Program of China 2018YFE0128500the Fundamental Research Funds for the Central Universities of China under Grant B210202069.
文摘More and more attention has been paid to the high penetration of renewable energy in recent years.The randomness and intermittency of solar and wind energy make it an inevitable trend that renewables are coupled with energy storage technologies.Pumped hydro storage(PHS)is the most widelyused storage form in the power grid but the capacity is limited by geographic conditions.The concentrated solar power(CSP)plant with a thermal energy storage(TES)system can realize easier grid connections and effective peak shaving.Therefore,this paper proposes a solar-wind-hydro hybrid power system with PHS-TES double energy storages,and investigates the optimal coordinated operational strategy and multi-objective sizing.The optimal sizing problem which considers the minimum levelized cost of energy(LCOE)and loss of power supply probability(LPSP)as objectives is solved by multi-objective particle swarm optimization.Moreover,the seasonal uncertainties of renewables are considered by applying a scenario-based analysis using Kmeans clustering.Finally,a case study reveals the effectiveness of the coordinated operational strategy and double energy storages from the perspectives of economy and reliability.The comparisons of optimal sizing results show that the PV-WindCSP-PHS system decreases the LCOE by 19.1%compared to a PV-Wind-CSP system under the same LPSP,and reduces the LPSP compared to PV-Wind-PHS systems with limited reservoir capacity,which indicates that the proposed system with double energy storages has better economy and reliability performance compared to single storage.
文摘In this study, ion mobility separation coupled with tandem mass spectrometry (IM-tandem MS) was utilized to investigate the ionization behaviors of two amino acids including leucine and isoleucine. Under the electrospray ionization (ESI) mode, two protonation sites in each molecular sturcture caused two forms of protomer. One arose from the amino being protonated (amino-protomer) and the other from the carboxyl being protonated (car- boxyl-protomer). In the two-dimensional (drift time, m/z) spectrum, the protomers had the same mass, but the dis- tinguishable drift times and fragmentation patterns. For the characterization purpose, the theoretical collision cross section (CCS) values of the protomers were calculated and proven to be consistent with the experimental. Moreover, the quantified relationship between the amino acids and their protomers was evaluated. It showed that the abun- dance of the carboxyl-protomer was proportional to the concentration of the amino acid, whereas that of the amino- protomer did not have the same trend. Under the atmospheric pressure chemical ionization (APCI) mode, only the carboxyl-protomer was observed. In addition, the amino-protomer and the cluster ions observed under ESI were absent completely. The results demonstrate that the ionization mode impacts heavily on the ionization behaviors of leucine and isoleucine not only on the form of therir protomers but also On the quantified relationship.