A 2.3 kJ Mather type pulsed plasma focus device was used for the synthesis of a TiN/a-Si3N4 thin film at room temperature. The film was characterized using X-ray diffraction (XRD), X-ray photoelectron spectroscopy ...A 2.3 kJ Mather type pulsed plasma focus device was used for the synthesis of a TiN/a-Si3N4 thin film at room temperature. The film was characterized using X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and atomic force microscopy (AFM). The XRD pattern confirms the growth of polycrystalline TiN thin film. The XPS results indicate that the synthesized film is non-stoichiometric and contains titanium nitride, silicon nitride, and a phase of silicon oxy-nitride. The SEM and AFM results reveal that the surface of the synthesized film is quite smooth with 0.59 nm roughness (root-mean-square).展开更多
The number of J/ψ events collected with the BES detector at the BEPC from June 12 to July 28, 2009 is determined to be (225.3 ± 2.8) × 10^ 6 using J/ψ→inclusive events, where the uncertainty is the syst...The number of J/ψ events collected with the BES detector at the BEPC from June 12 to July 28, 2009 is determined to be (225.3 ± 2.8) × 10^ 6 using J/ψ→inclusive events, where the uncertainty is the systematic error and the statistical one is negligible.展开更多
To investigate the nature of the Ψ(3770) resonance and to measure the cross section for e^+e^-→DD, a cross-section scan data sample, distributed among 41 center-of-mass energy points from 3.73 to 3.89 GeV, was ta...To investigate the nature of the Ψ(3770) resonance and to measure the cross section for e^+e^-→DD, a cross-section scan data sample, distributed among 41 center-of-mass energy points from 3.73 to 3.89 GeV, was taken with the BESIII detector operated at the BEPCII collider in the year 2010. By analyzing the large angle Bhabha scattering events, we measure the integrated luminosity of the data sample at each center-of-mass energy point. The total integrated luminosity of the data sample is 76.16±0.04±0.61 pb^-1, where the first uncertainty is statistical and the second systematic.展开更多
文摘A 2.3 kJ Mather type pulsed plasma focus device was used for the synthesis of a TiN/a-Si3N4 thin film at room temperature. The film was characterized using X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and atomic force microscopy (AFM). The XRD pattern confirms the growth of polycrystalline TiN thin film. The XPS results indicate that the synthesized film is non-stoichiometric and contains titanium nitride, silicon nitride, and a phase of silicon oxy-nitride. The SEM and AFM results reveal that the surface of the synthesized film is quite smooth with 0.59 nm roughness (root-mean-square).
基金Supported by Ministry of Science and Technology of China (2009CB825200)National Natural Science Foundation of China (NSFC) (10625524, 10821063, 10825524, 10835001, 10935007, 11125525)+3 种基金Joint Funds of National Natural Science Foundation of China (11079008, 11179007)Chinese Academy of Sciences (CAS) Large-Scale Scientific Facility Program (KJCX2-YW-N29, KJCX2-YW-N45)100 Talents Program of CAS, Istituto Nazionale di Fisica Nucleare, Italy, U. S. Department of Energy (DE-FG02-04ER41291, DE-FG02-91ER40682, DE-FG02-94ER40823)U.S. National Science Foundation, University of Groningen (RuG) and the Helmholtzzentrum fuer Schwerionenforschung GmbH (GSI), Darmstadt, WCU Program of National Research Foundation of Korea (R32-2008-000-10155-0)
文摘The number of J/ψ events collected with the BES detector at the BEPC from June 12 to July 28, 2009 is determined to be (225.3 ± 2.8) × 10^ 6 using J/ψ→inclusive events, where the uncertainty is the systematic error and the statistical one is negligible.
基金Supported by National Key Basic Research Program of China(2015CB856700)National Natural Science Foundation of China(NSFC)(11235011,11335008,11425524,11625523,11635010)+13 种基金the Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility Programthe CAS Center for Excellence in Particle Physics(CCEPP)Joint Large-Scale Scientific Facility Funds of the NSFCCAS(U1332201,U1532257,U1532258)CAS Key Research Program of Frontier Sciences(QYZDJ-SSW-SLH003,QYZDJ-SSW-SLH040)100 Talents Program of CASNational 1000 Talents Program of China,INPACShanghai Key Laboratory for Particle Physics and Cosmology,German Research Foundation DFG under Contracts Nos.Collaborative Research Center CRC 1044,FOR 2359Istituto Nazionale di Fisica Nucleare,Italy,Koninklijke Nederlandse Akademie van Wetenschappen(KNAW)(530-4CDP03)Ministry of Development of Turkey(DPT2006K-120470)National Science and Technology fundThe Swedish Research Council,U.S.Department of Energy(DEFG02-05ER41374,DE-SC-0010118,DE-SC-0010504,DE-SC-0012069)University of Groningen(RuG)and the Helmholtzzentrum fuer Schwerionenforschung GmbH(GSI)Darmstadt,WCU Program of National Research Foundation of Korea(R32-2008-000-10155-0)
文摘To investigate the nature of the Ψ(3770) resonance and to measure the cross section for e^+e^-→DD, a cross-section scan data sample, distributed among 41 center-of-mass energy points from 3.73 to 3.89 GeV, was taken with the BESIII detector operated at the BEPCII collider in the year 2010. By analyzing the large angle Bhabha scattering events, we measure the integrated luminosity of the data sample at each center-of-mass energy point. The total integrated luminosity of the data sample is 76.16±0.04±0.61 pb^-1, where the first uncertainty is statistical and the second systematic.