Combining Contactless Inductive Flow Tomography and Mutual Inductance Tomography for Two-Phase Flow Measurements at a Continuous Casting Model
1
作者 STEFANI Frank ECKERT Sven +7 位作者 GERBETH Gunter KLOTSCHE Konrad TIMMEL Klaus WONDRAK Thomas PEYTON Anthony J. terzija natasa YIN Wuliang 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2012年第S1期479-482,共4页
The flow structure in the mould of a continuous caster is of key importance for the quality of the final product. The use of most conventional flow measurement techniques is prevented by the high temperature of the li... The flow structure in the mould of a continuous caster is of key importance for the quality of the final product. The use of most conventional flow measurement techniques is prevented by the high temperature of the liquid steel.For a downscaled physical model of the continuous casting process,we present combined measurements of the flow in the mould by Contacfless Inductive Flow Tomography(CIFT),and of the conductivity distribution in the submerged entry nozzle by Mutual Inductance Tomograpliy(MIT).In addition,we summarize an experiment with a magnetic stirrer around the submerged entry nozzle and its effects on the flow in the mould.Some new developments towards a robust implementation of CIFT at a real caster,including the use of pickup coils and gradiometric probes,are also discussed. 展开更多
关键词 continuous casting flow measurements TOMOGRAPHY