期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Hybrid Chiller Plant Optimization Strategies for Hotel Building on Nile River of Egypt
1
作者 tarek a. mouneer Mohamed H. aly 《Journal of Power and Energy Engineering》 2021年第4期61-88,共28页
Hybrid<span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family... Hybrid<span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">chiller plants (HCPs)</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">using multiple chillers and different energy sources</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">are highly recommended in several energy applications in non-residential buildings such as hospitals and hotels. Time of use and cooling load profiles are significant factors that should be carefully considered either in chiller plant design or in chiller sequencing operation. This article aims to present an operation planning of HCP which consists of both electric and non-electric chillers. Four operational strategies are proposed and solved to compare their coefficients of performance and economics of running costs. A typical hotel building located on the Nile river in Egypt is selected to perform the current thermal and economic case study. The total cooling load profile of this hotel building is 4000 refrigeration tonnage (TR), which </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">is </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">simulated to optimize chiller sequence of operation and to select optimal design conditions of both numbers for electric and non-electric chillers used in HCP. The results of this comparative study for running cost are defined using various design configurations with different several chiller sequences available for each configuration. Then, the results of COPs, and operational running cost and initial cost are presented in this article also. The comparison aims to find the optimal design and operational sequencing for HCPs on thermal basis and economic analysis which were attached in this article. Recommendations and suggestions for future work are attached at the end of this article.</span></span></span> 展开更多
关键词 Hybrid Chiller Plant Sustainability in Buildings AIR-CONDITIONING Hotel Building Chiller Sequencing Building Cooling
下载PDF
Novel Cascade Refrigeration Cycle for Cold Supply Chain of COVID-19 Vaccines at Ultra-Low Temperature -80°C Using Ethane (R170) Based Hydrocarbon Pair
2
作者 tarek a. mouneer abdelrahman M. Elshaer Mohamed H. aly 《World Journal of Engineering and Technology》 2021年第2期309-336,共28页
Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines... Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines. This research presents the thermodynamic analysis on cascade refrigeration system (CRS) with several refrigerant pairs which are R32/R170, R123/R170, R134a/R170, R404A/R170, R407c/R170, R410/R170, and the hydrocarbon (HC) refrigerant pair Propane/Ethane, namely R290/R170. Besides, the results of R22/R170 pair, which is not recommended to be used due to phase out of R22 as per Montréal Protocol, are included as base case to compare the novel hydrocarbon pairs in CRS and the old trend of refrigerant pairs. Thermodynamic properties of all these pairs were investigated and compared under different intermediate temperature used in CRS heat exchanger, which thermally connected both the Low and High temperature cycles (LTC) and (HTC). By applying the first law of thermodynamics, the coefficients of performance (COPs) and the specific power consumptions (SPC) in kW/TR are presented and compared. In addition, by applying the second law of thermodynamics the exergetic efficiencies were estimated. The results reveal the promising opportunity of using the HC pair (R290/R170). The minimum SPC in kW/TR is recorded for the pair R123/R170. One the other hand, the highest exegetic efficiency values are observed to be 40%, 38%, and 35% for the pairs R123/R170, R290/R170, and R134/R170, respectively. This research concludes that the HC pair (R290/R170) is highly recommended for CRS applications either to transport the COVID-19 or store it in cold storage rooms in hospitals and clinics. All precautionary measures should be carefully applied in design and operation of HC pair (R290/R170) due to its flammability hazard. 展开更多
关键词 Cascade Refrigeration Cold Supply Chain COVID-19 Vaccine Ultra-Low Temperature -80°C Hydrocarbon Refrigerants Refrigerant Pair
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部