X-ray fluorescence microtomography(μXFCT)is a nondestructive analytical technique and has been widely used to nondestructively detect and quantify the elemental composition and distributions in samples. Usually, sync...X-ray fluorescence microtomography(μXFCT)is a nondestructive analytical technique and has been widely used to nondestructively detect and quantify the elemental composition and distributions in samples. Usually, synchrotron radiation X-rays are used for μXFCT, due to its high flux density. In this paper, a laboratory-sourcebased μXFCT system was developed, in which a polycapillary lens is employed to focus the X-ray beam and improve the flux density. The maximum likelihood expectation maximization algorithm was used to reconstruct the computed tomography slices at a limited number of projections. The experimental results demonstrated that the developed system could reveal the elemental distribution inside the test sample, with an elemental sensitivity of 1000 ppm.展开更多
The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical ...The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical devices,3D-XRF analysis with a micro confocal volume will create a great potential for 2D and 3D microstructural analysis and accurate quantitative analysis.However,the classic measurement method of scanning metal foils of a certain thickness leads to inaccuracy.A method for calibrating the confocal volume is proposed in this paper.The new method is based on the basic content of the textbook,and the theoretical results and the feasibility are given in detail for the 3D-XRF mono-chromatic x-ray condition and the poly-chromatic x-ray condition.We obtain a set of experimental confirmation using the poly-chromatic x-ray tube in the laboratory.It is proved that the sensitivity factor of the 3D-XRF can be directly and accurately obtained in a real calibration process.展开更多
基金supported by National Key R&D Program of China(Nos.2017YFA0206004 and 2017YFA0403800)the National Natural Science Foundation of China(Nos.11775297 and U1532118)
文摘X-ray fluorescence microtomography(μXFCT)is a nondestructive analytical technique and has been widely used to nondestructively detect and quantify the elemental composition and distributions in samples. Usually, synchrotron radiation X-rays are used for μXFCT, due to its high flux density. In this paper, a laboratory-sourcebased μXFCT system was developed, in which a polycapillary lens is employed to focus the X-ray beam and improve the flux density. The maximum likelihood expectation maximization algorithm was used to reconstruct the computed tomography slices at a limited number of projections. The experimental results demonstrated that the developed system could reveal the elemental distribution inside the test sample, with an elemental sensitivity of 1000 ppm.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11675019 and 11875087).
文摘The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical devices,3D-XRF analysis with a micro confocal volume will create a great potential for 2D and 3D microstructural analysis and accurate quantitative analysis.However,the classic measurement method of scanning metal foils of a certain thickness leads to inaccuracy.A method for calibrating the confocal volume is proposed in this paper.The new method is based on the basic content of the textbook,and the theoretical results and the feasibility are given in detail for the 3D-XRF mono-chromatic x-ray condition and the poly-chromatic x-ray condition.We obtain a set of experimental confirmation using the poly-chromatic x-ray tube in the laboratory.It is proved that the sensitivity factor of the 3D-XRF can be directly and accurately obtained in a real calibration process.