桩基础检测方法研究
1
作者 张智铭 王天全 +1 位作者 彭明强 王凯威 《工程设计与施工》 2020年第9期4-6,共3页
中国现代化建设的加速发展对建筑行业施工过程的质量和安全提出了更高的要求。桩基础检测是一项十分重要的工作,桩基检测方法的研究成为重要内容,论文旨在研究桩基础在施工中发生的各种问题,从而提前将安全隐患问题消除,对于保证后续施... 中国现代化建设的加速发展对建筑行业施工过程的质量和安全提出了更高的要求。桩基础检测是一项十分重要的工作,桩基检测方法的研究成为重要内容,论文旨在研究桩基础在施工中发生的各种问题,从而提前将安全隐患问题消除,对于保证后续施工的正常开展具有重要意义。 展开更多
关键词 桩基检测 检测技术 安全
下载PDF
Positron emission tomography detector performance with different crystal pitches 被引量:3
2
作者 LinGe Tong YaMing Fan +6 位作者 Ming Dong Liang Zhao ZhongXing Li YingGuo Li tianquan wang YongZhi Yin XiMeng Chen 《Radiation Detection Technology and Methods》 2017年第2期106-112,共7页
Aims:In this work,we evaluated the performance of three pitches positron emission tomography(PET)detectors for building a high-resolution small-animal PET imaging experimental platform.Methods:The evaluation of PET de... Aims:In this work,we evaluated the performance of three pitches positron emission tomography(PET)detectors for building a high-resolution small-animal PET imaging experimental platform.Methods:The evaluation of PET detectors includes twodimensional crystal identification,energy resolution,and crystal look-up table.The nuclear instrumentation module and PXI data acquisition(DAQ)system were both used to obtain flood images.The energy spectrum of the Na-22 source was measured.PET detectors of 2.0 and 1.6 mm pitches used in our present experiment were composed of lutetium yttrium oxyorthosilicate(LYSO)crystals directly coupled to position-sensitive photomultiplier tubes(PSPMTs).The 1.3-mm pitch detector comprises a LYSO crystal,a tapered light-guide,and a PSPMT.The crystal sizes of the detectors were a 10×10 array of 2.0×2.0×10 mm^(3) crystals,a 10×10 array of 1.6×1.6×10 mm^(3) crystals,and an 18×18 array of 1.3×1.3×10 mm^(3) crystals,respectively.Due to the lower sampling frequency of the DAQ system,a spline interpolation algorithm was introduced in the signal waveform to reconstruct the peak values.Results:The experimental results indicated that all three PET detector crystals could be clearly identified.A detailed analysis demonstrated that the key characteristic full width at half maximum(FWHM)values of the crystals profile could reach 0.46±0.03,0.32±0.03,and 0.21±0.02 mm,while the crystal average energy resolutions were 16.8%±1.76%,20.1%±2.24%,and 31.5%±3.76%,which correspond to pitches of 2.0-,1.6-,and 1.3-mm,respectively.Conclusions:The PET detector modules of LYSO crystal arrays could be potentially used in the small-animal PET imaging applications and are promising to achieve submillimeter PET images. 展开更多
关键词 PET detector Flood image Crystal look-up table
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部