期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Application of Hankel Dynamic Mode Decomposition for Wide Area Monitoring of Subsynchronous Resonance
1
作者 Lei Wang tiecheng li +3 位作者 Hui Fan Xuekai Hu lin Yang Xiaomei Yang 《Energy Engineering》 EI 2023年第4期851-867,共17页
In recent years,subsynchronous resonance(SSR)has frequently occurred in DFIG-connected series-compensated systems.For the analysis and prevention,it is of great importance to achieve wide area monitoring of the incide... In recent years,subsynchronous resonance(SSR)has frequently occurred in DFIG-connected series-compensated systems.For the analysis and prevention,it is of great importance to achieve wide area monitoring of the incident.This paper presents a Hankel dynamic mode decomposition(DMD)method to identify SSR parameters using synchrophasor data.The basic idea is to employ the DMD technique to explore the subspace of Hankel matrices constructed by synchrophasors.It is analytically demonstrated that the subspace of these Hankel matrices is a combination of fundamental and SSR modes.Therefore,the SSR parameters can be calculated once the modal parameter is extracted.Compared with the existing method,the presented work has better dynamic performances as it requires much less data.Thus,it is more suitable for practical cases in which the SSR characteristics are timevarying.The effectiveness and superiority of the proposed method have been verified by both simulations and field data. 展开更多
关键词 HANKEL dynamic mode decomposition TIME-VARYING sub-synchronous oscillation SYNCHROPHASOR
下载PDF
A Design of 220 kV Line Protection Action Deduction System Based on Numerical Simulation
2
作者 tiecheng li Qingquan liu +6 位作者 Hui Fan Xianzhi Wang Daming Zhou Junan Guo Lee li Kun Zhou Yujie Hu 《Energy Engineering》 EI 2022年第5期2105-2134,共30页
Accurate conditions monitoring and early wrong action warnings of relay protection in the Smart Substation is the basic guarantee to realize the normal operation of primary and secondary system of the power grid.At pr... Accurate conditions monitoring and early wrong action warnings of relay protection in the Smart Substation is the basic guarantee to realize the normal operation of primary and secondary system of the power grid.At present,the traditional operation and maintenance monitoring methods of relay protections have poor timeliness,while some automatic monitoring methods have insufficient early warning performance,and lack the online action deduction function independent of the actual device.In this paper,a design method of integrated action deduction system including protection logic reasoning and software and hardware operation condition is proposed.The system can receive real-time operation information of protection online,simulate different types of faults,and output the recording information of sub modules belongs to the action deduction system.It can realize the online monitoring of device faults such as deducing the correctness of setting values at a certain time in the future,giving the wrong action warnings and predicting the probability of them as well,which effectively improves the operation and maintenance efficiency of the secondary system in the intelligent substation. 展开更多
关键词 Intelligent substation numerical simulation relay protection conditions monitoring wrong action warning
下载PDF
Multi-area Frequency-constrained Unit Commitment for Power Systems with High Penetration of Renewable Energy Sources and Induction Machine Load
3
作者 Leibao Wang Hui Fan +5 位作者 Jifeng liang Longxun Xu tiecheng li Peng Luo Bo Hu Kaigui Xie 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第3期754-766,共13页
The increasing penetration of renewable energy sources(RESs)brings great challenges to the frequency security of power systems.The traditional frequency-constrained unit commitment(FCUC)analyzes frequency by simplifyi... The increasing penetration of renewable energy sources(RESs)brings great challenges to the frequency security of power systems.The traditional frequency-constrained unit commitment(FCUC)analyzes frequency by simplifying the average system frequency and ignoring numerous induction machines(IMs)in load,which may underestimate the risk and increase the operational cost.In this paper,we consider a multiarea frequency response(MAFR)model to capture the frequency dynamics in the unit scheduling problem,in which regional frequency security and the inertia of IM load are modeled with high-dimension differential algebraic equations.A multi-area FCUC(MFCUC)is formulated as mixed-integer nonlinear programming(MINLP)on the basis of the MAFR model.Then,we develop a multi-direction decomposition algorithm to solve the MFCUC efficiently.The original MINLP is decomposed into a master problem and subproblems.The subproblems check the nonlinear frequency dynamics and generate linear optimization cuts for the master problem to improve the frequency security in its optimal solution.Case studies on the modified IEEE 39-bus system and IEEE 118-bus system show a great reduction in operational costs.Moreover,simulation results verify the ability of the proposed MAFR model to reflect regional frequency security and the available inertia of IMs in unit scheduling. 展开更多
关键词 Decomposition algorithm frequency response frequency-constrained unit commitment induction machine multi-area mixed-integer nonlinear programming(MINLP)
原文传递