期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Evaluating the Efficacy of Cervical Tactile Ultrasound Technique as a Predictive Tool for Spontaneous Preterm Birth
1
作者 Vladimir Egorov todd rosen +4 位作者 Jennifer Hill Meena Khandelwal Victors Kurtenoks Brendan Francy Noune Sarvazyan 《Open Journal of Obstetrics and Gynecology》 2024年第5期832-846,共15页
Background: Premature cervical softening and shortening may be considered an early mechanical failure that predispose to preterm birth. Purpose: This study aims to explore the applicability of an innovative cervical t... Background: Premature cervical softening and shortening may be considered an early mechanical failure that predispose to preterm birth. Purpose: This study aims to explore the applicability of an innovative cervical tactile ultrasound approach for predicting spontaneous preterm birth (sPTB). Materials and Methods: Eligible participants were women with low-risk singleton pregnancies in their second trimester, enrolled in this prospective observational study. A Cervix Monitor (CM) device was designed with a vaginal probe comprising four tactile sensors and a single ultrasound transducer operating at 5 MHz. The probe enabled the application of controllable pressure to the external cervical surface, facilitating the acquisition of stress-strain data from both anterior and posterior cervical sectors. Gestational age at delivery was recorded and compared against cervical elasticity. Results: CM examination data were analyzed for 127 women at 24<sup>0/7</sup> - 28<sup>6/7</sup> gestational weeks. sPTB was observed in 6.3% of the cases. The preterm group exhibited a lower average cervical stress-to-strain ratio (elasticity) of 0.70 ± 0.26 kPa/mm compared to the term group’s 1.63 ± 0.65 kPa/mm with a p-value of 1.1 × 10<sup>−</sup><sup>4</sup>. Diagnostic accuracy for predicting spontaneous preterm birth based solely on cervical elasticity data was found to be 95.0% (95% CI, 88.5 - 100.0). Conclusion: These findings suggest that measuring cervical elasticity with the designed tactile ultrasound probe has the potential to predict spontaneous preterm birth in a cost-effective manner. 展开更多
关键词 Cervical Elasticity Spontaneous Preterm Birth Tactile Ultrasound Probe
下载PDF
Characterization of Perineum Elasticity and Pubic Bone-Perineal Critical Distance with a Novel Tactile Probe: Results of an Intraobserver Reproducibility Study
2
作者 Justin S. Brandt todd rosen +2 位作者 Heather Van Raalte Viktors Kurtenos Vladimir Egorov 《Open Journal of Obstetrics and Gynecology》 2020年第4期493-503,共11页
Background: Tactile imaging provides biomechanical mapping of soft tissues. Objective biomechanical and anatomical assessment of critical structures within the vagina and pelvis may allow development and validation of... Background: Tactile imaging provides biomechanical mapping of soft tissues. Objective biomechanical and anatomical assessment of critical structures within the vagina and pelvis may allow development and validation of a clinical tool that could assist with clinical decisions regarding obstetrical procedures and mode of delivery. Objective: To assess intraobserver reproducibility of measurements of perineal elasticity and pubic bone-perineal critical distance with a novel tactile probe in pregnant women. Methods: An Antepartum Tactile Imager (ATI) was designed with a vaginal probe resembling a fetal skull. The probe comprises 128 tactile sensors on a double curved surface and measures 46 mm in width and 72 mm in length. The probe has a motion tracking sensor that allows acquisition of 3D tactile images. There were two arms of the study. In the first arm, biomechanical mapping of the perineum and pelvic bone location was performed in 10 non-pregnant women for purposes of demonstrating safety and feasibility. In the second arm, biomechanical mapping was performed in 10 pregnant women to explore intraobserver reproducibility. Each subject had two standardized examinations over 3 - 5 minutes by the same observer. Examination comfort and pain levels were assessed by post-procedure survey. Reproducibility was analyzed by intraclass correlation coefficients (ICC) with 95% confidence intervals and Bland-Altman plots. Bias and the 95% limits of agreement were also calculated. Results: The safety and feasibility arm of the study demonstrated high degree of safety and tolerability and reliable acquisition of tactile signals. In the reproducibility arm, 10 pregnant women were recruited at mean gestational age of 34.2 ± 6.5 weeks. The mean perineum elasticity (Young’s modulus, E) was 9.8 ± 5.9 kPa, and the mean pubic bone-perineal critical distance (D) at 20 kPa load was 34.6 ± 6.2 mm. The ICC was 0.97 [95% confidence interval (CI) 0.91, 0.99] and 0.82 [CI 0.44, 0.95] for E and D respectively, consistent with excellent intrarater agreement. The bias and the 95% limits of agreement of E were -6.3% and -29.4% to +16.7%, respectively. The bias and the 95% limits of agreement of D were -2.6% and -25.3% to +20.2%, respectively. Conclusions: The tactile imaging data obtained in the study reproducibly characterized perineal elasticity and pubic bone-perineal critical distance. Further evaluation of this tool in clinical settings is warranted. 展开更多
关键词 PERINEAL ELASTICITY Tactile Imaging Elastography ANTEPARTUM Predictive Model Delivery Mode PERINEUM Maternal Birth Trauma
下载PDF
Cervical Characterization with Tactile-Ultrasound Probe
3
作者 Vladimir Egorov todd rosen +1 位作者 Heather van Raalte Viktors Kurtenoks 《Open Journal of Obstetrics and Gynecology》 2020年第1期85-99,共15页
Background: Premature cervical softening and shortening may be considered an early mechanical failure that predisposes to preterm birth. Preliminary clinical studies demonstrate that cervical elastography may be able ... Background: Premature cervical softening and shortening may be considered an early mechanical failure that predisposes to preterm birth. Preliminary clinical studies demonstrate that cervical elastography may be able to quantify this phenomenon and predict spontaneous preterm delivery. Objective: To explore a new approach for cervix elasticity and length measurements with tactile-ultrasound probe. Methods: Cervix probe has tactile array and ultrasound transducer designed to apply controllable load to cervix and acquire stress-strain data for calculation of cervical elasticity (Young’s modulus) and cervical length for four cervix sectors. Average values, standard deviations, intraclass correlation coefficients and the 95% limits of agreement (Bland-Altman plots) were estimated. Results: Ten non-pregnant and ten pregnant women were examined with the probe. The study with non-pregnant women demonstrated a reliable acquisition of the tactile signals. The ultrasound signals had a prolonged appearance;identification of the internal os of the cervix in these signals was not reliable. The study with pregnant women with the gestational age of 25.4 ± 2.3 weeks demonstrated reliable data acquisition with real-time visualization of the ultrasound signals. Average values for cervical elasticity and standard deviations of 19.7 ± 15.4 kPa and length of 30.7 ± 6.6 mm were calculated based on two measurements per 4 sectors. Measurement repeatability calculated as intraclass correlation coefficients between two measurements at the same cervix sector on pregnant women was found to be 0.97 for cervical elasticity and 0.93 for the cervical length. The 95% limits of agreement of 1) cervical elasticity were from ?22.4% to +14.9%, and 2) cervical length from ?13.3% to +16.5%. Conclusions: This study demonstrated clinically acceptable measurement performance and reproducibility. The availability of stress-strain data allowed the computation of cervical elasticity and length. This approach has the potential to provide cervical markers to predict spontaneous preterm delivery. 展开更多
关键词 CERVICAL Elasticity CERVICAL Length TACTILE Ultrasound ELASTOGRAPHY PREMATURE CERVICAL SOFTENING Spontaneous PRETERM Delivery
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部