期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
A vertical test system for China-ADS project injector Ⅱ superconducting cavities 被引量:1
1
作者 常玮 何源 +12 位作者 文良华 李春龙 薛纵横 宋玉堃 张锐 朱正龙 高郑 张聪 孙列鹏 岳伟明 张生虎 游志明 tom powers 《Chinese Physics C》 SCIE CAS CSCD 2014年第5期82-86,共5页
To test superconducting cavities, a vertical test system has been designed and set up at the Institute of Modern Physics (IMP). The system design is based on VCO-PLL hardware and the NI Labview software. The test of... To test superconducting cavities, a vertical test system has been designed and set up at the Institute of Modern Physics (IMP). The system design is based on VCO-PLL hardware and the NI Labview software. The test of the HWR010#2 superconducting cavity shows that the function of this test system is satisfactory for testing the low frequency cavity. 展开更多
关键词 vertical test superconducting cavity labview
原文传递
Study on transient beam loading compensation for China ADS proton linac injectorⅡ
2
作者 高郑 何源 +6 位作者 王贤武 常玮 张瑞锋 朱正龙 张生虎 陈奇 tom powers 《Chinese Physics C》 SCIE CAS CSCD 2016年第5期106-110,共5页
Significant transient beam loading effects were observed during beam commissioning tests of prototype II of the injector for the accelerator driven sub-critical (ADS) system, which took place at the Institute of Mod... Significant transient beam loading effects were observed during beam commissioning tests of prototype II of the injector for the accelerator driven sub-critical (ADS) system, which took place at the Institute of Modern Physics, Chinese Academy of Sciences, between October and December 2014. During these tests experiments were performed with continuous wave (CW) operation of the cavities with pulsed beam current, and the system was configured to make use of a prototype digital low level radio frequency (LLRF) controller. The system was originally operated in pulsed mode with a simple proportional plus integral and deviation (PID) feedback control algorithm, which was not able to maintain the desired gradient regulation during pulsed 10 mA beam operations. A unique simple transient beam loading compensation method which made use of a combination of proportional and integral (PI) feedback and feedforward control algorithm was implemented in order to significantly reduce the beam induced transient effect in the cavity gradients. The superconducting cavity field variation was reduced to less than 1.7% after turning on this control algorithm. The design and experimental results of this system are presented in this paper. 展开更多
关键词 beam loading LLRF FEEDFORWARD CAVITY FPGA
原文传递
上一页 1 下一页 到第