期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
应用超声生物显微镜检查浅前房眼附着性房角关闭的患病率
1
作者 Kunimatsu S. tomidokoro a. +1 位作者 Mishima K. 陈立军 《世界核心医学期刊文摘(眼科学分册)》 2005年第7期51-52,共2页
Purpose: To determine the prevalence of appositional angle closure in eyes with a shallow peripheral anterior chamber but no peripheral anterior synechia (PAS) in Japanese patients. Design: Cross- sectional study. Par... Purpose: To determine the prevalence of appositional angle closure in eyes with a shallow peripheral anterior chamber but no peripheral anterior synechia (PAS) in Japanese patients. Design: Cross- sectional study. Participants: Eighty eyes of 80 consecutive patients with a shallow peripheral anterior chamber, determined using the method of van Herick, and no PAS. Methods: The anterior chamber angle was classified according to Shaffer’ s grading with noncompression gonioscopy superiorly, inferiorly, temporally, and nasally. The absence of PAS was confirmed by compression gonioscopy if necessary. The presence of appositional angle closure and the trabecular- iris angle (T- I angle) was determined with ultrasound biomicroscopy in each quadrant under light and dark conditions. Factors related to appositional angle closure were studied using logistic analysis, and the covariates included gender, age, refraction, gonioscopic grading, and the quadrant of the angle measured. Main Outcome Measures: Gonioscopic grading of the angle width, the T- I angle, and the prevalence of appositional closure. Results: The gonioscopic grading (P< 0.001 in light and dark) and the T- I angle (P< 0.001 in light and dark) varied significantly among the 4 quadrants. Narrower angle gradings were observed more frequently superiorly. The T- I angle was narrower superiorly (in light) and inferiorly (in dark) (P< 0.001 and P=0.040, respectively). The T- I angle was significantly narrower in dark than in light (P< 0.001). The sites with the narrower gonioscopic gradings tended to have a smaller T- I angle (P< 0.001 and P=0.006 in light and dark, respectively). Conclusions: Appositional angle closure was found in at least 1 quadrant in46 (57.5% ) of 80 eyes in light and in 68 eyes (85% ) in dark. Logistic analysis showed that gonioscopic grading and the quadrant were significantly related to the presence of appositional angle closure in light and dark (P< 0.003 for both comparisons). Appositional angle closure was frequently observed in eyes with a shallow peripheral anterior chamber, especially under dark conditions in Japanese patients. The angle width, evaluated with conventional gonioscopic grading, and the quadrant of the angle were significantly related to the presence of appositional angle closure. 展开更多
关键词 超声生物显微镜 房角 浅前房 附着性 虹膜角 小梁 屈光状态 虹膜周边前粘连 压迫法 横断面研究
下载PDF
局部自体血清滴眼治疗迟发型滤过泡房水渗漏或点状渗漏
2
作者 Matsuo H. tomidokoro a. +2 位作者 Tomita G. araie M. 郭长梅 《世界核心医学期刊文摘(眼科学分册)》 2005年第6期33-33,共1页
Purpose. To evaluate the efficacy of topical autologous serum application to stop aqueous oozing or point-leak through filtering bleb after trabeculectomy. Patients and methods. A total of 21 consecutive eyes with ooz... Purpose. To evaluate the efficacy of topical autologous serum application to stop aqueous oozing or point-leak through filtering bleb after trabeculectomy. Patients and methods. A total of 21 consecutive eyes with oozing and 21 eyes with a point-leak through a functional bleb after trabeculectomy with 5- fluorouracil or mitomycin C were enrolled in this randomized, case-control study. In eyes randomly assigned to the serum group, an antibiotic and the autologous serum, which was sterilely diluted to 20% with physiological saline, were topically applied four times a day for up to 12 weeks. In eyes assigned to the control group, the antibiotic alone was applied according to the same protocol. Intraocular pressure (IOP) and the presence of oozing or a point-leak were tested before and every 2 weeks after starting the treatments. Results. In the serum and control groups, oozing stopped in 62.5 and 0% of eyes, respectively (P=0.003), and point-leaks stopped in 27.3 and 18.2% , respectively (P >0.9). IOP significantly increased from 10.0± 3.2 (mean± standard deviation) to 11.8± 3.3 mmHg in eyes in which oozing stopped (P=0.066), and from 11.4± 2.7 to 15.4± 2.3 mmHg in eyes in which a point-leak stopped (P=0.042). Conclusions. Autologous serum application was significantly effective to stop aqueous oozing but not point-leaks. Stopping oozing or point-leaks was significantly associated with an increase in IOP . 展开更多
关键词 房水渗漏 滤过泡 自体血清 小梁切除术 迟发型 眼内压 周检查 尿嘧啶 病例对照研究
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部