期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
An Innovative Concept of High-Dose-Rate (HDR) Intracavitary Brachytherapy with an Intrauterine Inflatable Balloon for Endometrial Carcinoma
1
作者 Abhilasha Patel Shannon Cummins +1 位作者 Join Y. Luh tony eng 《Journal of Cancer Therapy》 2014年第9期878-883,共6页
Purpose: Curative radiation therapy is an established treatment option for non-surgical patients with early-stage endometrial carcinoma. Dosimetric analyses were performed using a single tandem, double tandem, Heyman ... Purpose: Curative radiation therapy is an established treatment option for non-surgical patients with early-stage endometrial carcinoma. Dosimetric analyses were performed using a single tandem, double tandem, Heyman capsules, and an inflatable intrauterine balloon to assess the dose homogeneity and conformality in the definitive treatment of inoperable endometrial cancer. Methods and Materials: Patients’ informed-consent was obtained. Dosimetric analyses were performed using four different after-loading applicators to assess the dose homogeneity and conformality of isodose to the three-dimensional (3-D) shape of the target volume (uterus) based on CT data in four patients (n = 4). The single tandem and double tandems were standard Fletcher-type (Nucletron Corporation, Columbia, MD). Heyman capsules were the disposable after-loading type (Radiation Products Design, Inc., Albertville, MN). The inflatable balloon with a central bi-lumen catheter was the Mammo Site Radiation Therapy System (Proxima Therapeutics, Alpharetta, GA) that is currently used for local breast brachytherapy. Treatment planning and dosimetric analyses for all four techniques were done with HDR PLATO Brachytherapy (v14.2.3) Software (Nucletron Corporation). Results: The average dose gradient within the target (uterine wall) is highest with the tandem methods, followed by Heyman capsules. The intrauterine balloon method showed the least dose gradient across the uterine wall. The corresponding average homogeneity indices were 3.81, 3.83, 2.97, 2.50 for single tandem, double tandem, Heyman capsules, and intrauterine balloon respectively. Conclusions: The intra-uterine inflatable balloon appears to have the best overall dosimetric advantages for the treatment of the uterine wall. Furthermore, the potential ease of use, shorter time of applicator placement, and better patient comfort warrant further investigation and subsequent clinical implementation. 展开更多
关键词 Intracavitary BALLOON BRACHYTHERAPY HIGH-DOSE-RATE ENDOMETRIAL Cancer
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部