期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Unsteady Flow Condition between Front and Rear Rotor of Contra-Rotating Small Sized Axial Fan 被引量:3
1
作者 toru shigemitsu Hiroaki Fukuda Katsuhiko Hirosawa 《Open Journal of Fluid Dynamics》 2017年第3期371-385,共15页
Contra-rotating small-sized axial fans are used as cooling fans for electric equipment. In the case of the contra-rotating rotors, the blade row distance between front and rear rotors is a key parameter for the perfor... Contra-rotating small-sized axial fans are used as cooling fans for electric equipment. In the case of the contra-rotating rotors, the blade row distance between front and rear rotors is a key parameter for the performance and stable operation. The wake and potential interference occur between the front and rear rotors and leakage flow from the front rotor tip influences on the flow condition of the rear rotor near the shroud when the blade row distance is small. Therefore, it is important to clarify the flow condition between front and rear rotors. The fan static pressure curves were obtained by the experimental apparatus and the numerical analysis was also conducted to investigate the internal flow between front and rear rotors. The leakage flow from the front rotor tip reaches the leading edge of the rear rotor when the blade row distance is small as L = 10 mm and the pressure fluctuations at the leading edge of the rear rotor tip becomes larger than those at other radial positions. In the present paper, the vorticity contour between front and rear rotors is shown and pressure fluctuations related to the leakage flow from the front rotor is investigated using the numerical analysis result. Then, suitable blade row distance for the contra-rotating small sized axial fan is discussed based on the internal flow condition. 展开更多
关键词 TURBOMACHINERY Contra-Rotating Axial FLOW FAN LEAKAGE FLOW WAKE
下载PDF
Internal Flow Condition between Front and Rear Rotor of Contra-Rotating Small-Sized Axial Fan at Low Flow Rate
2
作者 toru shigemitsu Kensuke Tanaka +1 位作者 Katsuhiko Hirosawa Keisuke Miyazaki 《Open Journal of Fluid Dynamics》 2017年第4期709-723,共15页
Contra-rotating small-sized fans are used as cooling fans for electric equipment. The internal flow condition between the front and rear rotors of the contra-rotating small-sized fan is not known well especially at th... Contra-rotating small-sized fans are used as cooling fans for electric equipment. The internal flow condition between the front and rear rotors of the contra-rotating small-sized fan is not known well especially at the low flow rate. Furthermore, the blade row distance between the front and rear rotors is an important parameter for the contra-rotating small-sized fan and its influence on the internal flow condition is not clarified at the low flow rate. Therefore, the internal flow condition of the contra-rotating small-sized fan at the low flow rate is investigated by the numerical analysis in this research. The numerical analysis results are validated by comparing the fan static pressure curves of the numerical results to the experimental results. The internal flow condition at the low flow rate is clarified using the numerical models of the different blade row distance L = 10 mm and 30 mm. In the present paper, pressure fluctuations phase locked each front and rear rotor’s rotation are shown and the influences of the wake and the potential interference are discussed by the unsteady numerical analysis results at the low flow rate. 展开更多
关键词 Small-Sized Axial FAN Contra-Rotating Rotors WAKE Potential Interference Numerical Analysis
下载PDF
Performance and Internal Flow of Contra-Rotating Small-Sized Cooling Fan
3
作者 toru shigemitsu Keisuke Miyazaki +1 位作者 Katsuhiko Hirosawa Hiroaki Fukuda 《Open Journal of Fluid Dynamics》 2018年第2期181-194,共14页
High pressure and large flow rate small-sized cooling fans are used for servers in data centers and there is a strong demand to increase its performance because of increase of quantity of heat from servers. Contra-rot... High pressure and large flow rate small-sized cooling fans are used for servers in data centers and there is a strong demand to increase its performance because of increase of quantity of heat from servers. Contra-rotating rotors have been adopted for some of high pressure and large flow rate cooling fans to meet the demand. The performance curve of the contra-rotating small-sized cooling fan with 40 mm square casing was investigated by an experimental apparatus and its internal flow condition was clarified by the numerical analysis. The fan static pressure of the front rotor was extremely low and it increased significantly at the rear rotor. The uniform flow was achieved at the inlet of the rear rotor because of the special shape of the casing between the front and rear rotors. On the other hand, the tip leakage flow was large enough to influence on the main flow of the test cooling fan by the design specification of high pressure with compact rotor diameter. 展开更多
关键词 COOLING FAN Small-Sized AXIAL FAN Contra-Rotating Rotors PERFORMANCE INTERNAL Flow
下载PDF
Performance Test and Flow Measurement of Contra-Rotating Axial Flow Pump 被引量:18
4
作者 Akinori Furukawa toru shigemitsu Satoshi Watanabe 《Journal of Thermal Science》 SCIE EI CAS CSCD 2007年第1期7-13,共7页
contra-rotating 转子的一个应用程序对对开发更高特定的速度的一个要求被建议了轴的流动泵。在现在的纸,使用 contra-rotating 转子的优点和劣势与转子定子的常规类型比较被描述,基于理论、试验性的调查。优点如下:(1 ) 泵内在地作... contra-rotating 转子的一个应用程序对对开发更高特定的速度的一个要求被建议了轴的流动泵。在现在的纸,使用 contra-rotating 转子的优点和劣势与转子定子的常规类型比较被描述,基于理论、试验性的调查。优点如下:(1 ) 泵内在地作为更小被设计缩放并且以更低的旋转速度。(2 ) 为有否定斜坡的流动率的一条稳定的头特征曲线出现。(3 ) 作为后面的转子,旋转速度作为前面转子的独立控制被改变,高效操作的更宽的范围被后面的转子速度控制除了前面转子速度控制获得。劣势如下:(1 ) 两倍柄系统的结构变得复杂。(2 ) 泵表演是劣等的在在是的流动率上,装载的后面的转子被削弱。(3 ) 片更强烈从后面的转子划相互作用到前面转子出现。当时,后面的转子设计是一把钥匙完成更高的泵性能。克服这些劣势的一些方法将向 contra-rotating 的更宽的用法更详细地被讨论各种各样的工业地里的轴的流动泵。 展开更多
关键词 转子对转 轴流泵 性能试验 流量计量 多相流
原文传递
Pressure Measurement on Casing Wall and Blade Rows Interaction of Contra-Rotating Axial Flow Pump 被引量:2
5
作者 toru shigemitsu Tomoya TAKANO +2 位作者 Akinori FURUKAWA Kusuo OKUMA Satoshi WATANABE 《Journal of Thermal Science》 SCIE EI CAS CSCD 2005年第2期142-149,共8页
An application of contra-rotating rotors has been proposed against a demand for developing higher specific speed axial flow pump. The blade rows interaction between front and rear rotors should be clarified for its st... An application of contra-rotating rotors has been proposed against a demand for developing higher specific speed axial flow pump. The blade rows interaction between front and rear rotors should be clarified for its stable operation and reduction of unsteady losses. In this paper, the static pressure distributions on casing wall are provided by measuring with the phase locked sampling method. The measurements are carried out for two types of the rear rotors with different blade number and chord length, and it is found that, for both types of rotors, the unsteady pressure fluctuations are more remarkable in the front rotor than in the rear rotor and they are caused by the rear rotor pressure field. The effects of pressure fluctuations will be discussed in more details toward understanding the blade rows interaction in the contra-rotating axial flow pump. 展开更多
关键词 涡轮机 逆旋转转子 压力场 叶栅交感 测量方法
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部