Based on the boundary condition of field engineering, numerical simulations of28 conditions of existing diffusers of 3 structure types were investigated by ComputationalFluid Dynamics software package, and there were ...Based on the boundary condition of field engineering, numerical simulations of28 conditions of existing diffusers of 3 structure types were investigated by ComputationalFluid Dynamics software package, and there were the problems of larger structure resistanceand lower diffusing efficiency of these diffusers by analysis of CFD results.Thestructure outlines of the energy-saving diffuser were constructed by the application ofstream function and potential function superimposing.On the basis of numerical simulationsof energy-saving diffusers of 5 area-enlarging ratios, structural resistances and diffusingefficiencies of 5 energy-saving diffusers were comparatively analyzed, and therange from 2.00 to 2.31 of the rational area-enlarging ratio of energy-saving diffusers wasderived.The optimization area-enlarging ratio of the energy-saving diffuser was presently2.28 through comparable analysis.From the above, the results show that the coefficient ofperformance of the energy-saving diffuser is better than 3 existing diffusers.展开更多
Based on the engineering application, the angle range of rectifying airflow unit attaching diffusion tank is from 2.5° to 7.5°. In the range of average inlet velocity of 25.0 m/s to 55.0 m/s of diffusion tan...Based on the engineering application, the angle range of rectifying airflow unit attaching diffusion tank is from 2.5° to 7.5°. In the range of average inlet velocity of 25.0 m/s to 55.0 m/s of diffusion tank, numerical simulations of diffusion tank were done. The results of numerical simulations of diffusion tank are shown as follows: ③ In cases of the inlet velocity range from 25.0 m/s to 55.0 m/s, and the angle range of rectifying airflow unit from 2.5° to 7.5°, the average value of pressure losses decreases to the minimum when the angle is 4.5°.② In cases of the inlet velocity of 35.0 m/s, the pressure loss of diffusion tank decreases to the minimum when the angle of rectifying airflow unit is 5.5°. ③ As far as there are different angles of rectifying airflow unit, pressure loss increases gradually along with the addition of inlet velocity.展开更多
According to the action law of gas flow during injecting inert gases as the research main line, and hydromechanics and thermodynamics theories, the characteristic of gas delamination that was caused by injecting inert...According to the action law of gas flow during injecting inert gases as the research main line, and hydromechanics and thermodynamics theories, the characteristic of gas delamination that was caused by injecting inert gases to closed fire zone was analyzed. The criterion was brought forward, which could scale disappearing probability of turbulent state. Formation mechanism of gas layer in turbulent state was discussed primarily. Simultaneously, the condition was pointed out, which could makc the gas in turbulent state by injecting different gases. The mathematical model about dynamic changes of oxygen and methane concentration in the process of injecting gases was erected. The mixture mechanism about injecting different flow inert gases and flammable gas layer in closed fire zone was revealed.展开更多
In order to improve the thermal environment of high-temperature heading face,moisture content of supply air is reduced by dehumidification, and the relative humidity ofenvironment air of the heading face is also decre...In order to improve the thermal environment of high-temperature heading face,moisture content of supply air is reduced by dehumidification, and the relative humidity ofenvironment air of the heading face is also decreased.First, according to the coefficient ofperformance of dehumidifier, the capacity of dehumidification was calculated.Second, inthe engineering example of the heading face, quantitative changes of WBGT (Wet BulbGlobe Temperature) were compared between with dehumidification and without dehumidification.Based on WBGT standards, the thermal comfort of high-temperature environmentof heading face was evaluated between with dehumidification and without handling.Reducingthe relative humidity of airflow through dehumidification, the thermal comfort of ahigh-temperature environment of heading face can improve greatly.Even if dry bulb temperatureof airflow is not decreased, the thermal comfort of heading face environment isalso improved to some extent.展开更多
基金Supported by the National Natural Science Foundation of China(50974060)the Scientific Research Fund of Hunan Provincial Education Department(09CY014)the Doctoral Fund of Hunan University of Science and Technology
文摘Based on the boundary condition of field engineering, numerical simulations of28 conditions of existing diffusers of 3 structure types were investigated by ComputationalFluid Dynamics software package, and there were the problems of larger structure resistanceand lower diffusing efficiency of these diffusers by analysis of CFD results.Thestructure outlines of the energy-saving diffuser were constructed by the application ofstream function and potential function superimposing.On the basis of numerical simulationsof energy-saving diffusers of 5 area-enlarging ratios, structural resistances and diffusingefficiencies of 5 energy-saving diffusers were comparatively analyzed, and therange from 2.00 to 2.31 of the rational area-enlarging ratio of energy-saving diffusers wasderived.The optimization area-enlarging ratio of the energy-saving diffuser was presently2.28 through comparable analysis.From the above, the results show that the coefficient ofperformance of the energy-saving diffuser is better than 3 existing diffusers.
基金Supported by the National Natural Science Foundation of China (51074073) the Project of Hunan Provincial Science & Technology Department (2010XK6066) the Project of Scientific Research Fund of Hunan Provincial Education Department (10C0675)
文摘Based on the engineering application, the angle range of rectifying airflow unit attaching diffusion tank is from 2.5° to 7.5°. In the range of average inlet velocity of 25.0 m/s to 55.0 m/s of diffusion tank, numerical simulations of diffusion tank were done. The results of numerical simulations of diffusion tank are shown as follows: ③ In cases of the inlet velocity range from 25.0 m/s to 55.0 m/s, and the angle range of rectifying airflow unit from 2.5° to 7.5°, the average value of pressure losses decreases to the minimum when the angle is 4.5°.② In cases of the inlet velocity of 35.0 m/s, the pressure loss of diffusion tank decreases to the minimum when the angle of rectifying airflow unit is 5.5°. ③ As far as there are different angles of rectifying airflow unit, pressure loss increases gradually along with the addition of inlet velocity.
文摘According to the action law of gas flow during injecting inert gases as the research main line, and hydromechanics and thermodynamics theories, the characteristic of gas delamination that was caused by injecting inert gases to closed fire zone was analyzed. The criterion was brought forward, which could scale disappearing probability of turbulent state. Formation mechanism of gas layer in turbulent state was discussed primarily. Simultaneously, the condition was pointed out, which could makc the gas in turbulent state by injecting different gases. The mathematical model about dynamic changes of oxygen and methane concentration in the process of injecting gases was erected. The mixture mechanism about injecting different flow inert gases and flammable gas layer in closed fire zone was revealed.
基金Supported by Hunan Province Science and Technology(2007FJ1012)the Scientific Research Fund of Hunan Provincial Education Department(09CY014)Doctoral Fund of HNUST
文摘In order to improve the thermal environment of high-temperature heading face,moisture content of supply air is reduced by dehumidification, and the relative humidity ofenvironment air of the heading face is also decreased.First, according to the coefficient ofperformance of dehumidifier, the capacity of dehumidification was calculated.Second, inthe engineering example of the heading face, quantitative changes of WBGT (Wet BulbGlobe Temperature) were compared between with dehumidification and without dehumidification.Based on WBGT standards, the thermal comfort of high-temperature environmentof heading face was evaluated between with dehumidification and without handling.Reducingthe relative humidity of airflow through dehumidification, the thermal comfort of ahigh-temperature environment of heading face can improve greatly.Even if dry bulb temperatureof airflow is not decreased, the thermal comfort of heading face environment isalso improved to some extent.